Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation

Purpose - To apply velocity selective arterial spin labeling (VSASL) combined with a navigator-based (NAV) prospective motion compensation method for a free-breathing liver perfusion measurement without contrast agent. - Methods - Sinc-modulated Velocity Selective Inversion (sinc-VSI) pulses were ap...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zhang, Ke (VerfasserIn) , Triphan, Simon M. F. (VerfasserIn) , Wielpütz, Mark Oliver (VerfasserIn) , Ziener, Christian H. (VerfasserIn) , Ladd, Mark E. (VerfasserIn) , Schlemmer, Heinz-Peter (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Sedlaczek, Oliver (VerfasserIn) , Kurz, Felix T. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: February 2025
In: Zeitschrift für medizinische Physik
Year: 2025, Jahrgang: 35, Heft: 1, Pages: 87-97
ISSN:1876-4436
DOI:10.1016/j.zemedi.2024.06.001
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.zemedi.2024.06.001
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0939388924000515
Volltext
Verfasserangaben:Ke Zhang, Simon M. F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Oliver Sedlaczek, Felix T. Kurz

MARC

LEADER 00000naa a2200000 c 4500
001 1936827212
003 DE-627
005 20250925113857.0
007 cr uuu---uuuuu
008 250925s2025 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.zemedi.2024.06.001  |2 doi 
035 |a (DE-627)1936827212 
035 |a (DE-599)KXP1936827212 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Zhang, Ke  |d 1984-  |e VerfasserIn  |0 (DE-588)142064564  |0 (DE-627)704133199  |0 (DE-576)327160438  |4 aut 
245 1 0 |a Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation  |c Ke Zhang, Simon M. F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Oliver Sedlaczek, Felix T. Kurz 
264 1 |c February 2025 
300 |b Illustrationen 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar 2 July 2024, Version des Artikels 26 February 2025 
500 |a Gesehen am 25.09.2025 
520 |a Purpose - To apply velocity selective arterial spin labeling (VSASL) combined with a navigator-based (NAV) prospective motion compensation method for a free-breathing liver perfusion measurement without contrast agent. - Methods - Sinc-modulated Velocity Selective Inversion (sinc-VSI) pulses were applied as labeling and control pulses. In order to account for respiratory motion, a navigator was employed in the form of a single gradient-echo projection readout, located at the diaphragm along the inferior-superior direction. Prior to each transverse imaging slice of the spin-echo EPI based readouts, navigator and fat suppression were incorporated. Motion data was obtained from the navigator and transmitted back to the sequence, allowing real-time adjustments to slice positioning. The sinc-VSI without velocity-selective gradients during the control condition but with velocity-selective gradients along all three directions during labeling was chosen for the VSASL. The VSASL was compared with pseudo-continuous ASL (pCASL) methods, which selectively tagged the moving spins using a tagging plane placed at the portal vein and hepatic artery. - Results - The motion caused by respiratory activity was effectively computed using the navigator signal. The coefficients of variation (CoV) of average liver voxel in NAV were significantly decreased when compared to breath-hold (BH), with an average reduction of 29.4±18.44% for control images, and 29.89±20.83% for label images (p<0.001). The resulting maps of normalized ASL signal (normalized to M0) showed significantly higher perfusion weightings in the NAV-compensated VSASL, when compared to the NAV-compensated pCASL techniques. - Conclusions - This study demonstrates the feasibility of using a navigator-based prospective motion compensation technique in conjunction with VSASL for the measurement of liver perfusion without the use of contrast agents while allowing for free-breathing. 
650 4 |a Liver perfusion 
650 4 |a Navigator-based slice tracking 
650 4 |a Prospective motion compensation 
650 4 |a Velocity selective arterial spin labeling 
700 1 |a Triphan, Simon M. F.  |e VerfasserIn  |0 (DE-588)1072565080  |0 (DE-627)827729553  |0 (DE-576)434034207  |4 aut 
700 1 |a Wielpütz, Mark Oliver  |d 1982-  |e VerfasserIn  |0 (DE-588)139999752  |0 (DE-627)614754682  |0 (DE-576)314127046  |4 aut 
700 1 |a Ziener, Christian H.  |d 1978-  |e VerfasserIn  |0 (DE-588)137982755  |0 (DE-627)59885309X  |0 (DE-576)306117355  |4 aut 
700 1 |a Ladd, Mark E.  |e VerfasserIn  |0 (DE-588)108120964X  |0 (DE-627)845690507  |0 (DE-576)454039999  |4 aut 
700 1 |a Schlemmer, Heinz-Peter  |e VerfasserIn  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Sedlaczek, Oliver  |d 1970-  |e VerfasserIn  |0 (DE-588)123144493  |0 (DE-627)706179838  |0 (DE-576)293576173  |4 aut 
700 1 |a Kurz, Felix T.  |d 1981-  |e VerfasserIn  |0 (DE-588)1043285474  |0 (DE-627)771321066  |0 (DE-576)394610342  |4 aut 
773 0 8 |i Enthalten in  |t Zeitschrift für medizinische Physik  |d Amsterdam [u.a.] : Elsevier, 1990  |g 35(2025), 1 vom: Feb., Seite 87-97  |w (DE-627)510617662  |w (DE-600)2231492-1  |w (DE-576)272350818  |x 1876-4436  |7 nnas  |a Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation 
773 1 8 |g volume:35  |g year:2025  |g number:1  |g month:02  |g pages:87-97  |g extent:11  |a Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation 
856 4 0 |u https://doi.org/10.1016/j.zemedi.2024.06.001  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0939388924000515  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20250925 
993 |a Article 
994 |a 2025 
998 |g 1043285474  |a Kurz, Felix T.  |m 1043285474:Kurz, Felix T.  |d 50000  |e 50000PK1043285474  |k 0/50000/  |p 9  |y j 
998 |g 123144493  |a Sedlaczek, Oliver  |m 123144493:Sedlaczek, Oliver  |d 910000  |d 911400  |e 910000PS123144493  |e 911400PS123144493  |k 0/910000/  |k 1/910000/911400/  |p 8 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 7 
998 |g 108120964X  |a Ladd, Mark E.  |m 108120964X:Ladd, Mark E.  |p 5 
998 |g 137982755  |a Ziener, Christian H.  |m 137982755:Ziener, Christian H.  |d 50000  |e 50000PZ137982755  |k 0/50000/  |p 4 
998 |g 139999752  |a Wielpütz, Mark Oliver  |m 139999752:Wielpütz, Mark Oliver  |d 50000  |e 50000PW139999752  |k 0/50000/  |p 3 
998 |g 1072565080  |a Triphan, Simon M. F.  |m 1072565080:Triphan, Simon M. F.  |d 910000  |d 911400  |d 50000  |e 910000PT1072565080  |e 911400PT1072565080  |e 50000PT1072565080  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 2 
998 |g 142064564  |a Zhang, Ke  |m 142064564:Zhang, Ke  |d 910000  |d 911400  |e 910000PZ142064564  |e 911400PZ142064564  |k 0/910000/  |k 1/910000/911400/  |p 1  |x j 
999 |a KXP-PPN1936827212  |e 4775958968 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"language":["eng"],"note":["Online verfügbar 2 July 2024, Version des Artikels 26 February 2025","Gesehen am 25.09.2025"],"title":[{"title_sort":"Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation","title":"Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation"}],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"February 2025"}],"person":[{"role":"aut","given":"Ke","family":"Zhang","display":"Zhang, Ke"},{"family":"Triphan","given":"Simon M. F.","role":"aut","display":"Triphan, Simon M. F."},{"display":"Wielpütz, Mark Oliver","given":"Mark Oliver","role":"aut","family":"Wielpütz"},{"display":"Ziener, Christian H.","role":"aut","given":"Christian H.","family":"Ziener"},{"display":"Ladd, Mark E.","role":"aut","given":"Mark E.","family":"Ladd"},{"display":"Schlemmer, Heinz-Peter","family":"Schlemmer","given":"Heinz-Peter","role":"aut"},{"role":"aut","given":"Hans-Ulrich","family":"Kauczor","display":"Kauczor, Hans-Ulrich"},{"family":"Sedlaczek","given":"Oliver","role":"aut","display":"Sedlaczek, Oliver"},{"display":"Kurz, Felix T.","role":"aut","given":"Felix T.","family":"Kurz"}],"relHost":[{"titleAlt":[{"title":"Medizinische Physik"}],"pubHistory":["Volume 1, supplement (1990) ; volume 1, issue 1 (1991)-"],"corporate":[{"display":"Deutsche Gesellschaft für Medizinische Physik","role":"isb"},{"role":"isb","display":"Österreichische Gesellschaft für Medizinische Physik"}],"id":{"issn":["1876-4436"],"eki":["510617662"],"zdb":["2231492-1"]},"part":{"year":"2025","volume":"35","pages":"87-97","issue":"1","text":"35(2025), 1 vom: Feb., Seite 87-97","extent":"11"},"origin":[{"dateIssuedDisp":"1990-","dateIssuedKey":"1990","publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier"}],"title":[{"title_sort":"Zeitschrift für medizinische Physik","title":"Zeitschrift für medizinische Physik","subtitle":"offizielles Organ der Deutschen, Österreichischen und Schweizerischen Gesellschaft für Medizinische Physik"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"language":["ger"],"note":["Gesehen am 31.01.2022"],"recId":"510617662","disp":"Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensationZeitschrift für medizinische Physik"}],"physDesc":[{"noteIll":"Illustrationen","extent":"11 S."}],"recId":"1936827212","id":{"doi":["10.1016/j.zemedi.2024.06.001"],"eki":["1936827212"]},"name":{"displayForm":["Ke Zhang, Simon M. F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Oliver Sedlaczek, Felix T. Kurz"]}} 
SRT |a ZHANGKETRINONCONTRAS2025