Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes

Characterization of pancreatic capillary blood flow by in vivo microscopy has been limited by technical shortcoming associated with the use of plasma tracers and the lack of quantitative data. Therefore, fluorescent-labeled erythrocytes were evaluated for quantitation of pancreatic capillary blood f...

Full description

Saved in:
Bibliographic Details
Main Authors: Mithöfer, Kai (Author) , Schmidt, Jan (Author) , Gebhard, Martha-Maria (Author) , Buhr, Heinz J. (Author) , Herfarth, Christian (Author) , Klar, Ernst (Author)
Format: Article (Journal)
Language:English
Published: January 1995
In: Microvascular research
Year: 1995, Volume: 49, Issue: 1, Pages: 33-48
ISSN:1095-9319
DOI:10.1006/mvre.1995.1004
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1006/mvre.1995.1004
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0026286285710047
Get full text
Author Notes:Kai Mithöfer, Jan Schmidt, Martha M. Gebhard, Heinz J. Buhr, Christian Herfarth, Ernst Klar

MARC

LEADER 00000naa a2200000 c 4500
001 1936988593
003 DE-627
005 20250925135906.0
007 cr uuu---uuuuu
008 250925s1995 xx |||||o 00| ||eng c
024 7 |a 10.1006/mvre.1995.1004  |2 doi 
035 |a (DE-627)1936988593 
035 |a (DE-599)KXP1936988593 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mithöfer, Kai  |e VerfasserIn  |0 (DE-588)137741518X  |0 (DE-627)1936989018  |4 aut 
245 1 0 |a Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes  |c Kai Mithöfer, Jan Schmidt, Martha M. Gebhard, Heinz J. Buhr, Christian Herfarth, Ernst Klar 
264 1 |c January 1995 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Elektronische Reproduktion der Druck-Ausgabe 25. Mai 2002 
500 |a Gesehen am 25.09.2025 
520 |a Characterization of pancreatic capillary blood flow by in vivo microscopy has been limited by technical shortcoming associated with the use of plasma tracers and the lack of quantitative data. Therefore, fluorescent-labeled erythrocytes were evaluated for quantitation of pancreatic capillary blood flow in rats in physiological state and under defined conditions of increased and impaired pancreatic blood flow. Physiological blood flow was 1.21 ± 0.06 nl/min per capillary with stable capillary perfusion pattern. Reduction of pancreatic blood flow by decreasing systemic arterial pressure to 60 mm Hg through controlled hemorrhage produced a profound decrease of volumetric flow to 0.21 ± 0.05 nl/min (P < 0.05). The number of perfused capillaries was reduced to 52 ± 8% of baseline (P < 0.001) and the intermittent perfusion pattern was altered in 26 ± 5% (P < 0.001) of observed capillaries. Stimulation of pancreatic perfusion with intravenous secretin (5 CU/kg/hr) induced a transient decline to 0.94 nl/min (P < 0.05) followed by a continuous increase to 2.39 nl/min (P < 0.001). The intermittent flow pattern was modified in 15 ± 3% of capillaries (P < 0.05). Fluorescent-labeled erythrocytes provide unique and reliable qualitative and quantitative data about pancreatic microcirculatory changes. Confinement of the fluorescent tracer to erythrocytes prevents extravasation and minimizes phototoxicity, thereby improving intravital analysis of blood flow in pancreatic exchange capillaries. 
700 1 |a Schmidt, Jan  |d 1961-  |e VerfasserIn  |0 (DE-588)1022937995  |0 (DE-627)717335852  |0 (DE-576)366198017  |4 aut 
700 1 |a Gebhard, Martha-Maria  |d 1948-  |e VerfasserIn  |0 (DE-588)1076763278  |0 (DE-627)835312879  |0 (DE-576)445612789  |4 aut 
700 1 |a Buhr, Heinz J.  |d 1945-  |e VerfasserIn  |0 (DE-588)115821767  |0 (DE-627)077495039  |0 (DE-576)174713320  |4 aut 
700 1 |a Herfarth, Christian  |d 1933-2014  |e VerfasserIn  |0 (DE-588)120706385  |0 (DE-627)080841562  |0 (DE-576)213333414  |4 aut 
700 1 |a Klar, Ernst  |d 1952-  |e VerfasserIn  |0 (DE-588)136455107  |0 (DE-627)582906431  |0 (DE-576)301029326  |4 aut 
773 0 8 |i Enthalten in  |t Microvascular research  |d Orlando, Fla. : Academic Press, 1968  |g 49(1995), 1, Seite 33-48  |h Online-Ressource  |w (DE-627)267840284  |w (DE-600)1471172-2  |w (DE-576)104193980  |x 1095-9319  |7 nnas  |a Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes 
773 1 8 |g volume:49  |g year:1995  |g number:1  |g pages:33-48  |g extent:16  |a Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes 
856 4 0 |u https://doi.org/10.1006/mvre.1995.1004  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0026286285710047  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20250925 
993 |a Article 
994 |a 1995 
998 |g 136455107  |a Klar, Ernst  |m 136455107:Klar, Ernst  |d 910000  |d 910200  |e 910000PK136455107  |e 910200PK136455107  |k 0/910000/  |k 1/910000/910200/  |p 6  |y j 
998 |g 120706385  |a Herfarth, Christian  |m 120706385:Herfarth, Christian  |d 910000  |d 910200  |e 910000PH120706385  |e 910200PH120706385  |k 0/910000/  |k 1/910000/910200/  |p 5 
998 |g 115821767  |a Buhr, Heinz J.  |m 115821767:Buhr, Heinz J.  |d 50000  |e 50000PB115821767  |k 0/50000/  |p 4 
998 |g 1076763278  |a Gebhard, Martha-Maria  |m 1076763278:Gebhard, Martha-Maria  |d 910000  |d 910200  |e 910000PG1076763278  |e 910200PG1076763278  |k 0/910000/  |k 1/910000/910200/  |p 3 
998 |g 1022937995  |a Schmidt, Jan  |m 1022937995:Schmidt, Jan  |d 910000  |d 910200  |e 910000PS1022937995  |e 910200PS1022937995  |k 0/910000/  |k 1/910000/910200/  |p 2 
998 |g 137741518X  |a Mithöfer, Kai  |m 137741518X:Mithöfer, Kai  |d 910000  |d 910200  |e 910000PM137741518X  |e 910200PM137741518X  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1936988593  |e 4775993348 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedKey":"1995","dateIssuedDisp":"January 1995"}],"name":{"displayForm":["Kai Mithöfer, Jan Schmidt, Martha M. Gebhard, Heinz J. Buhr, Christian Herfarth, Ernst Klar"]},"recId":"1936988593","note":["Elektronische Reproduktion der Druck-Ausgabe 25. Mai 2002","Gesehen am 25.09.2025"],"physDesc":[{"extent":"16 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"doi":["10.1006/mvre.1995.1004"],"eki":["1936988593"]},"title":[{"title":"Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes","title_sort":"Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytes"}],"relHost":[{"id":{"eki":["267840284"],"issn":["1095-9319"],"zdb":["1471172-2"]},"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.1968/69 -"],"part":{"text":"49(1995), 1, Seite 33-48","issue":"1","pages":"33-48","year":"1995","extent":"16","volume":"49"},"origin":[{"publisher":"Academic Press ; Elsevier","dateIssuedDisp":"1968-","dateIssuedKey":"1968","publisherPlace":"Orlando, Fla. ; Amsterdam [u.a.]"}],"recId":"267840284","titleAlt":[{"title":"MVR"}],"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title":"Microvascular research","subtitle":"MVR","title_sort":"Microvascular research"}],"language":["eng"],"note":["Gesehen am 20.02.20"],"disp":"Measurement of blood flow in pancreatic exchange capillaries with FITC-labeled erythrocytesMicrovascular research"}],"language":["eng"],"person":[{"family":"Mithöfer","given":"Kai","display":"Mithöfer, Kai","role":"aut"},{"display":"Schmidt, Jan","role":"aut","family":"Schmidt","given":"Jan"},{"given":"Martha-Maria","family":"Gebhard","role":"aut","display":"Gebhard, Martha-Maria"},{"display":"Buhr, Heinz J.","role":"aut","family":"Buhr","given":"Heinz J."},{"given":"Christian","family":"Herfarth","role":"aut","display":"Herfarth, Christian"},{"role":"aut","display":"Klar, Ernst","given":"Ernst","family":"Klar"}]} 
SRT |a MITHOEFERKMEASUREMEN1995