Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms

BACKGROUND AND OBJECTIVES: - Flow Redirection Endoluminal Device (FRED) X is a new generation flow diverter with an antithrombotic surface coating. This study compares the procedural safety and short-term efficacy of FRED X with its uncoated predecessor, the FRED. - METHODS: -...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Görtz, Lukas (VerfasserIn) , Hohenstatt, Sophia (VerfasserIn) , Vollherbst, Dominik (VerfasserIn) , Styczen, Hanna (VerfasserIn) , Siebert, Eberhard (VerfasserIn) , Bohner, Georg (VerfasserIn) , Deuschl, Cornelius (VerfasserIn) , Möhlenbruch, Markus Alfred (VerfasserIn) , Kabbasch, Christoph (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: May 2025
In: Neurosurgery
Year: 2025, Jahrgang: 96, Heft: 5, Pages: 997-1007
ISSN:1524-4040
DOI:10.1227/neu.0000000000003188
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1227/neu.0000000000003188
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/neurosurgery/fulltext/2025/05000/lower_ischemic_risk_profile_of_coated_flow.10.aspx
Volltext
Verfasserangaben:Lukas Goertz, MD, Sophia Hohenstatt, MD, Dominik F. Vollherbst, MD, Hanna Styczen, MD, Eberhard Siebert, MD, Georg Bohner, MD, Cornelius Deuschl, MD, Markus A. Möhlenbruch, MD, Christoph Kabbasch, MD

MARC

LEADER 00000caa a2200000 c 4500
001 1937624919
003 DE-627
005 20251120193500.0
007 cr uuu---uuuuu
008 251002s2025 xx |||||o 00| ||eng c
024 7 |a 10.1227/neu.0000000000003188  |2 doi 
035 |a (DE-627)1937624919 
035 |a (DE-599)KXP1937624919 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Görtz, Lukas  |e VerfasserIn  |0 (DE-588)1321680643  |0 (DE-627)1881564207  |4 aut 
245 1 0 |a Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms  |c Lukas Goertz, MD, Sophia Hohenstatt, MD, Dominik F. Vollherbst, MD, Hanna Styczen, MD, Eberhard Siebert, MD, Georg Bohner, MD, Cornelius Deuschl, MD, Markus A. Möhlenbruch, MD, Christoph Kabbasch, MD 
264 1 |c May 2025 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 8. Oktober 2024 
500 |a Gesehen am 02.10.2025 
520 |a BACKGROUND AND OBJECTIVES: - Flow Redirection Endoluminal Device (FRED) X is a new generation flow diverter with an antithrombotic surface coating. This study compares the procedural safety and short-term efficacy of FRED X with its uncoated predecessor, the FRED. - METHODS: - Patients treated with FRED and FRED X devices for unruptured aneurysms between 2013 and 2023 at 3 neurovascular centers were retrospectively reviewed. The procedural ischemic event rate was the safety end point, and the complete aneurysm occlusion rate at 1 year was the efficacy end point. Multivariable regression adjustment and 1:1 propensity score matching were performed to control for potential confounding. - RESULTS: - The FRED X group (137 patients) had a higher prevalence of recurrent and bifurcation aneurysms and fewer aneurysms with branch involvement than the FRED X group (156 patients). The ischemic event rate was lower in FRED X (1/156 [0.6%]) than in FRED (7/137 [5.1%]), which was significant after multivariable adjustment (odds ratio: 8.8, 95% CI: 1.1-72.7, P = .04), and tended to be significant in the propensity score analysis (P = .07). Morbidity was comparable between FRED (2.2%) and FRED X (0%, P = .10). The complete occlusion rates of FRED vs FRED X were 73/117 (62.4%) vs 39/54 (72.2%) aneurysms at 6 months (P = .21) and 52/74 (70.3%) vs 27/37 (73.0%) at 12 months (P = .77). Hemorrhagic complications, in-stent stenosis, and clinical events during follow-up and retreatments were not significantly different between groups. - CONCLUSION: - This study indicates an improved ischemic risk profile of FRED X while maintaining a favorable efficacy profile, warranting further study and translation into clinical use. 
700 1 |a Hohenstatt, Sophia  |d 1994-  |e VerfasserIn  |0 (DE-588)1284014207  |0 (DE-627)1839711493  |4 aut 
700 1 |a Vollherbst, Dominik  |d 1989-  |e VerfasserIn  |0 (DE-588)1071379569  |0 (DE-627)825819024  |0 (DE-576)407878866  |4 aut 
700 1 |a Styczen, Hanna  |e VerfasserIn  |4 aut 
700 1 |a Siebert, Eberhard  |e VerfasserIn  |4 aut 
700 1 |a Bohner, Georg  |e VerfasserIn  |4 aut 
700 1 |a Deuschl, Cornelius  |e VerfasserIn  |4 aut 
700 1 |a Möhlenbruch, Markus Alfred  |d 1979-  |e VerfasserIn  |0 (DE-588)137693591  |0 (DE-627)594845041  |0 (DE-576)304845655  |4 aut 
700 1 |a Kabbasch, Christoph  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Neurosurgery  |d Alphen aan den Rijn : Wolters Kluwer, 1977  |g 96(2025), 5 vom: Mai, Seite 997-1007  |w (DE-627)302718729  |w (DE-600)1491894-8  |w (DE-576)079876668  |x 1524-4040  |7 nnas  |a Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms 
773 1 8 |g volume:96  |g year:2025  |g number:5  |g month:05  |g pages:997-1007  |g extent:11  |a Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms 
856 4 0 |u https://doi.org/10.1227/neu.0000000000003188  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://journals.lww.com/neurosurgery/fulltext/2025/05000/lower_ischemic_risk_profile_of_coated_flow.10.aspx  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20251002 
993 |a Article 
994 |a 2025 
998 |g 137693591  |a Möhlenbruch, Markus Alfred  |m 137693591:Möhlenbruch, Markus Alfred  |d 910000  |d 911100  |d 50000  |e 910000PM137693591  |e 911100PM137693591  |e 50000PM137693591  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 8 
998 |g 1071379569  |a Vollherbst, Dominik  |m 1071379569:Vollherbst, Dominik  |d 910000  |d 911100  |d 50000  |e 910000PV1071379569  |e 911100PV1071379569  |e 50000PV1071379569  |k 0/910000/  |k 1/910000/911100/  |k 0/50000/  |p 3 
998 |g 1284014207  |a Hohenstatt, Sophia  |m 1284014207:Hohenstatt, Sophia  |d 910000  |d 911100  |e 910000PH1284014207  |e 911100PH1284014207  |k 0/910000/  |k 1/910000/911100/  |p 2 
999 |a KXP-PPN1937624919  |e 477991194X 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1937624919"],"doi":["10.1227/neu.0000000000003188"]},"physDesc":[{"extent":"11 S."}],"title":[{"title_sort":"Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms","title":"Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"May 2025"}],"relHost":[{"title":[{"title":"Neurosurgery","subtitle":"official journal of the Congress of Neurological Surgeons","title_sort":"Neurosurgery"}],"id":{"zdb":["1491894-8"],"eki":["302718729"],"issn":["1524-4040"]},"origin":[{"dateIssuedDisp":"1977-","publisher":"Wolters Kluwer ; Lippincott Williams & Wilkins ; Ovid ; Oxford University Press","publisherPlace":"Alphen aan den Rijn ; Baltimore, Md. ; [Erscheinungsort nicht ermittelbar] ; Oxford","dateIssuedKey":"1977"}],"recId":"302718729","disp":"Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysmsNeurosurgery","type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"Neurosurgery online"}],"language":["eng"],"part":{"text":"96(2025), 5 vom: Mai, Seite 997-1007","extent":"11","pages":"997-1007","issue":"5","year":"2025","volume":"96"},"pubHistory":["1.1977 -"],"note":["Gesehen am 25.05.2022"]}],"language":["eng"],"name":{"displayForm":["Lukas Goertz, MD, Sophia Hohenstatt, MD, Dominik F. Vollherbst, MD, Hanna Styczen, MD, Eberhard Siebert, MD, Georg Bohner, MD, Cornelius Deuschl, MD, Markus A. Möhlenbruch, MD, Christoph Kabbasch, MD"]},"note":["Online veröffentlicht: 8. Oktober 2024","Gesehen am 02.10.2025"],"recId":"1937624919","person":[{"family":"Görtz","role":"aut","display":"Görtz, Lukas","given":"Lukas"},{"role":"aut","family":"Hohenstatt","given":"Sophia","display":"Hohenstatt, Sophia"},{"role":"aut","family":"Vollherbst","display":"Vollherbst, Dominik","given":"Dominik"},{"given":"Hanna","display":"Styczen, Hanna","family":"Styczen","role":"aut"},{"given":"Eberhard","display":"Siebert, Eberhard","family":"Siebert","role":"aut"},{"family":"Bohner","role":"aut","given":"Georg","display":"Bohner, Georg"},{"role":"aut","family":"Deuschl","given":"Cornelius","display":"Deuschl, Cornelius"},{"family":"Möhlenbruch","role":"aut","given":"Markus Alfred","display":"Möhlenbruch, Markus Alfred"},{"family":"Kabbasch","role":"aut","given":"Christoph","display":"Kabbasch, Christoph"}]} 