Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms
BACKGROUND AND OBJECTIVES: - Flow Redirection Endoluminal Device (FRED) X is a new generation flow diverter with an antithrombotic surface coating. This study compares the procedural safety and short-term efficacy of FRED X with its uncoated predecessor, the FRED. - METHODS: -...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
May 2025
|
| In: |
Neurosurgery
Year: 2025, Jahrgang: 96, Heft: 5, Pages: 997-1007 |
| ISSN: | 1524-4040 |
| DOI: | 10.1227/neu.0000000000003188 |
| Online-Zugang: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1227/neu.0000000000003188 Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/neurosurgery/fulltext/2025/05000/lower_ischemic_risk_profile_of_coated_flow.10.aspx |
| Verfasserangaben: | Lukas Goertz, MD, Sophia Hohenstatt, MD, Dominik F. Vollherbst, MD, Hanna Styczen, MD, Eberhard Siebert, MD, Georg Bohner, MD, Cornelius Deuschl, MD, Markus A. Möhlenbruch, MD, Christoph Kabbasch, MD |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1937624919 | ||
| 003 | DE-627 | ||
| 005 | 20251120193500.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 251002s2025 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1227/neu.0000000000003188 |2 doi | |
| 035 | |a (DE-627)1937624919 | ||
| 035 | |a (DE-599)KXP1937624919 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Görtz, Lukas |e VerfasserIn |0 (DE-588)1321680643 |0 (DE-627)1881564207 |4 aut | |
| 245 | 1 | 0 | |a Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms |c Lukas Goertz, MD, Sophia Hohenstatt, MD, Dominik F. Vollherbst, MD, Hanna Styczen, MD, Eberhard Siebert, MD, Georg Bohner, MD, Cornelius Deuschl, MD, Markus A. Möhlenbruch, MD, Christoph Kabbasch, MD |
| 264 | 1 | |c May 2025 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online veröffentlicht: 8. Oktober 2024 | ||
| 500 | |a Gesehen am 02.10.2025 | ||
| 520 | |a BACKGROUND AND OBJECTIVES: - Flow Redirection Endoluminal Device (FRED) X is a new generation flow diverter with an antithrombotic surface coating. This study compares the procedural safety and short-term efficacy of FRED X with its uncoated predecessor, the FRED. - METHODS: - Patients treated with FRED and FRED X devices for unruptured aneurysms between 2013 and 2023 at 3 neurovascular centers were retrospectively reviewed. The procedural ischemic event rate was the safety end point, and the complete aneurysm occlusion rate at 1 year was the efficacy end point. Multivariable regression adjustment and 1:1 propensity score matching were performed to control for potential confounding. - RESULTS: - The FRED X group (137 patients) had a higher prevalence of recurrent and bifurcation aneurysms and fewer aneurysms with branch involvement than the FRED X group (156 patients). The ischemic event rate was lower in FRED X (1/156 [0.6%]) than in FRED (7/137 [5.1%]), which was significant after multivariable adjustment (odds ratio: 8.8, 95% CI: 1.1-72.7, P = .04), and tended to be significant in the propensity score analysis (P = .07). Morbidity was comparable between FRED (2.2%) and FRED X (0%, P = .10). The complete occlusion rates of FRED vs FRED X were 73/117 (62.4%) vs 39/54 (72.2%) aneurysms at 6 months (P = .21) and 52/74 (70.3%) vs 27/37 (73.0%) at 12 months (P = .77). Hemorrhagic complications, in-stent stenosis, and clinical events during follow-up and retreatments were not significantly different between groups. - CONCLUSION: - This study indicates an improved ischemic risk profile of FRED X while maintaining a favorable efficacy profile, warranting further study and translation into clinical use. | ||
| 700 | 1 | |a Hohenstatt, Sophia |d 1994- |e VerfasserIn |0 (DE-588)1284014207 |0 (DE-627)1839711493 |4 aut | |
| 700 | 1 | |a Vollherbst, Dominik |d 1989- |e VerfasserIn |0 (DE-588)1071379569 |0 (DE-627)825819024 |0 (DE-576)407878866 |4 aut | |
| 700 | 1 | |a Styczen, Hanna |e VerfasserIn |4 aut | |
| 700 | 1 | |a Siebert, Eberhard |e VerfasserIn |4 aut | |
| 700 | 1 | |a Bohner, Georg |e VerfasserIn |4 aut | |
| 700 | 1 | |a Deuschl, Cornelius |e VerfasserIn |4 aut | |
| 700 | 1 | |a Möhlenbruch, Markus Alfred |d 1979- |e VerfasserIn |0 (DE-588)137693591 |0 (DE-627)594845041 |0 (DE-576)304845655 |4 aut | |
| 700 | 1 | |a Kabbasch, Christoph |e VerfasserIn |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Neurosurgery |d Alphen aan den Rijn : Wolters Kluwer, 1977 |g 96(2025), 5 vom: Mai, Seite 997-1007 |w (DE-627)302718729 |w (DE-600)1491894-8 |w (DE-576)079876668 |x 1524-4040 |7 nnas |a Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms |
| 773 | 1 | 8 | |g volume:96 |g year:2025 |g number:5 |g month:05 |g pages:997-1007 |g extent:11 |a Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms |
| 856 | 4 | 0 | |u https://doi.org/10.1227/neu.0000000000003188 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://journals.lww.com/neurosurgery/fulltext/2025/05000/lower_ischemic_risk_profile_of_coated_flow.10.aspx |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20251002 | ||
| 993 | |a Article | ||
| 994 | |a 2025 | ||
| 998 | |g 137693591 |a Möhlenbruch, Markus Alfred |m 137693591:Möhlenbruch, Markus Alfred |d 910000 |d 911100 |d 50000 |e 910000PM137693591 |e 911100PM137693591 |e 50000PM137693591 |k 0/910000/ |k 1/910000/911100/ |k 0/50000/ |p 8 | ||
| 998 | |g 1071379569 |a Vollherbst, Dominik |m 1071379569:Vollherbst, Dominik |d 910000 |d 911100 |d 50000 |e 910000PV1071379569 |e 911100PV1071379569 |e 50000PV1071379569 |k 0/910000/ |k 1/910000/911100/ |k 0/50000/ |p 3 | ||
| 998 | |g 1284014207 |a Hohenstatt, Sophia |m 1284014207:Hohenstatt, Sophia |d 910000 |d 911100 |e 910000PH1284014207 |e 911100PH1284014207 |k 0/910000/ |k 1/910000/911100/ |p 2 | ||
| 999 | |a KXP-PPN1937624919 |e 477991194X | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"id":{"eki":["1937624919"],"doi":["10.1227/neu.0000000000003188"]},"physDesc":[{"extent":"11 S."}],"title":[{"title_sort":"Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms","title":"Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysms"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"May 2025"}],"relHost":[{"title":[{"title":"Neurosurgery","subtitle":"official journal of the Congress of Neurological Surgeons","title_sort":"Neurosurgery"}],"id":{"zdb":["1491894-8"],"eki":["302718729"],"issn":["1524-4040"]},"origin":[{"dateIssuedDisp":"1977-","publisher":"Wolters Kluwer ; Lippincott Williams & Wilkins ; Ovid ; Oxford University Press","publisherPlace":"Alphen aan den Rijn ; Baltimore, Md. ; [Erscheinungsort nicht ermittelbar] ; Oxford","dateIssuedKey":"1977"}],"recId":"302718729","disp":"Lower-ischemic-risk profile of coated flow redirection endoluminal device X compared with uncoated flow redirection endoluminal device flow diverter in the treatment of unruptured intracranial aneurysmsNeurosurgery","type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"Neurosurgery online"}],"language":["eng"],"part":{"text":"96(2025), 5 vom: Mai, Seite 997-1007","extent":"11","pages":"997-1007","issue":"5","year":"2025","volume":"96"},"pubHistory":["1.1977 -"],"note":["Gesehen am 25.05.2022"]}],"language":["eng"],"name":{"displayForm":["Lukas Goertz, MD, Sophia Hohenstatt, MD, Dominik F. Vollherbst, MD, Hanna Styczen, MD, Eberhard Siebert, MD, Georg Bohner, MD, Cornelius Deuschl, MD, Markus A. Möhlenbruch, MD, Christoph Kabbasch, MD"]},"note":["Online veröffentlicht: 8. Oktober 2024","Gesehen am 02.10.2025"],"recId":"1937624919","person":[{"family":"Görtz","role":"aut","display":"Görtz, Lukas","given":"Lukas"},{"role":"aut","family":"Hohenstatt","given":"Sophia","display":"Hohenstatt, Sophia"},{"role":"aut","family":"Vollherbst","display":"Vollherbst, Dominik","given":"Dominik"},{"given":"Hanna","display":"Styczen, Hanna","family":"Styczen","role":"aut"},{"given":"Eberhard","display":"Siebert, Eberhard","family":"Siebert","role":"aut"},{"family":"Bohner","role":"aut","given":"Georg","display":"Bohner, Georg"},{"role":"aut","family":"Deuschl","given":"Cornelius","display":"Deuschl, Cornelius"},{"family":"Möhlenbruch","role":"aut","given":"Markus Alfred","display":"Möhlenbruch, Markus Alfred"},{"family":"Kabbasch","role":"aut","given":"Christoph","display":"Kabbasch, Christoph"}]} | ||
| SRT | |a GOERTZLUKALOWERISCHE2025 | ||