Safety and efficacy of a plug-based vascular closure device after percutaneous microaxial flow pump in the treatment of complex and high-risk indicated patients

Background Femoral large-bore vascular access is an important and constantly increasing technique in interventional treatment. Temporary circulatory support in complex and high-risk indicated patients (CHIP) presents a challenge in terms of postinterventional access site closure. Aim Monitoring the...

Full description

Saved in:
Bibliographic Details
Main Authors: Schröder, Jörg Walter (Author) , Mangner, Norman (Author) , Woitek, Felix J. (Author) , Markus, Kai U. (Author) , Lehrke, Michael (Author) , Vogt, Felix (Author) , Verket, Marlo (Author) , Siskos, Alexandros (Author) , Biener, Moritz (Author) , Meder, Benjamin (Author) , Van Mieghem, Nicolas M. (Author)
Format: Article (Journal)
Language:English
Published: July 1, 2025
In: Catheterization and cardiovascular interventions
Year: 2025, Volume: 106, Issue: 1, Pages: 189-195
ISSN:1522-726X
DOI:10.1002/ccd.31528
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1002/ccd.31528
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/ccd.31528
Get full text
Author Notes:Jörg W. Schröder, Norman Mangner, Felix J. Woitek, Kai U. Markus, Michael Lehrke, Felix Vogt, Marlo Verket, Alexandros Siskos, Moritz Biener, Benjamin Meder, Nicolas M. Van Mieghem

MARC

LEADER 00000naa a2200000 c 4500
001 1937962830
003 DE-627
005 20251008095709.0
007 cr uuu---uuuuu
008 251008s2025 xx |||||o 00| ||eng c
024 7 |a 10.1002/ccd.31528  |2 doi 
035 |a (DE-627)1937962830 
035 |a (DE-599)KXP1937962830 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schröder, Jörg Walter  |d 1968-  |e VerfasserIn  |0 (DE-588)1209982579  |0 (DE-627)1698059159  |4 aut 
245 1 0 |a Safety and efficacy of a plug-based vascular closure device after percutaneous microaxial flow pump in the treatment of complex and high-risk indicated patients  |c Jörg W. Schröder, Norman Mangner, Felix J. Woitek, Kai U. Markus, Michael Lehrke, Felix Vogt, Marlo Verket, Alexandros Siskos, Moritz Biener, Benjamin Meder, Nicolas M. Van Mieghem 
264 1 |c July 1, 2025 
300 |b Illustrationen 
300 |a 7 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 10 April 2025 
500 |a Gesehen am 08.10.2025 
520 |a Background Femoral large-bore vascular access is an important and constantly increasing technique in interventional treatment. Temporary circulatory support in complex and high-risk indicated patients (CHIP) presents a challenge in terms of postinterventional access site closure. Aim Monitoring the safety and efficacy of the MANTA system (Teleflex Inc.), a plug-based vascular closure device (PbVCD) in patients receiving a percutaneous microaxial flow pump (mAFP). Methods A multicenter prospective all-comers registry enrolled 73 consecutive patients scheduled for PbVCD after receiving mAFP for CHIP or cardiogenic shock. The primary endpoint was the occurrence of vascular complications at the mAFP access site until discharge according to the Valve Academic Research Consortium-3 (VARC-3) definition. Secondary endpoints included the rate of procedure- or device-related bleedings, device-failures, and the time to hemostasis. Operators rated on the use of the MANTA System and the similarity compared to ANGIOSEAL (Terumo Medical Corp.). Results Hemostasis was achieved in all 73 patients with no need for alternative treatment other than manual compression. The primary endpoint occurred in 7 (9.6%) patients with 1 (1.4%) patient suffering from a major vascular complication and 6 (8.2%) patients developing hematoma with type 2 bleeding (minor vascular complication). There was no vessel closure or thromboembolic event. In-hospital survival was 100%. Conclusions The PbVCD system is a safe, efficient and easy-to-use vascular closure system for large-bore vascular access in patients receiving a mAFP. Advantages and disadvantages of PbVCD and suture-based vascular closure devices (SbVCD) systems should be individually adapted according to the patient's medical history and the anatomy of the vascular constellation. 
650 4 |a bleeding 
650 4 |a CHIP 
650 4 |a Manta 
650 4 |a outcome 
650 4 |a percutaneous microaxial flow pump 
650 4 |a plug-based vascular closure device 
700 1 |a Mangner, Norman  |e VerfasserIn  |4 aut 
700 1 |a Woitek, Felix J.  |e VerfasserIn  |4 aut 
700 1 |a Markus, Kai U.  |e VerfasserIn  |4 aut 
700 1 |a Lehrke, Michael  |e VerfasserIn  |4 aut 
700 1 |a Vogt, Felix  |e VerfasserIn  |4 aut 
700 1 |a Verket, Marlo  |e VerfasserIn  |4 aut 
700 1 |a Siskos, Alexandros  |e VerfasserIn  |4 aut 
700 1 |a Biener, Moritz  |d 1983-  |e VerfasserIn  |0 (DE-588)101853119X  |0 (DE-627)682858374  |0 (DE-576)355963876  |4 aut 
700 1 |a Meder, Benjamin  |e VerfasserIn  |0 (DE-588)135821630  |0 (DE-627)571676316  |0 (DE-576)300664745  |4 aut 
700 1 |a Van Mieghem, Nicolas M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Catheterization and cardiovascular interventions  |d New York, NY : Wiley Interscience, 1999  |g 106(2025), 1 vom: Juli, Seite 189-195  |h Online-Ressource  |w (DE-627)320413004  |w (DE-600)2001555-0  |w (DE-576)091014794  |x 1522-726X  |7 nnas  |a Safety and efficacy of a plug-based vascular closure device after percutaneous microaxial flow pump in the treatment of complex and high-risk indicated patients 
773 1 8 |g volume:106  |g year:2025  |g number:1  |g month:07  |g pages:189-195  |g extent:7  |a Safety and efficacy of a plug-based vascular closure device after percutaneous microaxial flow pump in the treatment of complex and high-risk indicated patients 
856 4 0 |u https://doi.org/10.1002/ccd.31528  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/ccd.31528  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20251008 
993 |a Article 
994 |a 2025 
998 |g 135821630  |a Meder, Benjamin  |m 135821630:Meder, Benjamin  |d 910000  |d 910100  |e 910000PM135821630  |e 910100PM135821630  |k 0/910000/  |k 1/910000/910100/  |p 10 
998 |g 101853119X  |a Biener, Moritz  |m 101853119X:Biener, Moritz  |d 50000  |e 50000PB101853119X  |k 0/50000/  |p 9 
999 |a KXP-PPN1937962830  |e 4782582285 
BIB |a Y 
SER |a journal 
JSO |a {"person":[{"role":"aut","family":"Schröder","display":"Schröder, Jörg Walter","given":"Jörg Walter"},{"family":"Mangner","role":"aut","display":"Mangner, Norman","given":"Norman"},{"given":"Felix J.","family":"Woitek","role":"aut","display":"Woitek, Felix J."},{"family":"Markus","role":"aut","display":"Markus, Kai U.","given":"Kai U."},{"role":"aut","family":"Lehrke","display":"Lehrke, Michael","given":"Michael"},{"given":"Felix","display":"Vogt, Felix","family":"Vogt","role":"aut"},{"role":"aut","family":"Verket","display":"Verket, Marlo","given":"Marlo"},{"role":"aut","family":"Siskos","display":"Siskos, Alexandros","given":"Alexandros"},{"family":"Biener","role":"aut","display":"Biener, Moritz","given":"Moritz"},{"family":"Meder","role":"aut","display":"Meder, Benjamin","given":"Benjamin"},{"given":"Nicolas M.","family":"Van Mieghem","role":"aut","display":"Van Mieghem, Nicolas M."}],"language":["eng"],"note":["Veröffentlicht: 10 April 2025","Gesehen am 08.10.2025"],"name":{"displayForm":["Jörg W. Schröder, Norman Mangner, Felix J. Woitek, Kai U. Markus, Michael Lehrke, Felix Vogt, Marlo Verket, Alexandros Siskos, Moritz Biener, Benjamin Meder, Nicolas M. Van Mieghem"]},"origin":[{"dateIssuedDisp":"July 1, 2025","dateIssuedKey":"2025"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1937962830"],"doi":["10.1002/ccd.31528"]},"recId":"1937962830","title":[{"title":"Safety and efficacy of a plug-based vascular closure device after percutaneous microaxial flow pump in the treatment of complex and high-risk indicated patients","title_sort":"Safety and efficacy of a plug-based vascular closure device after percutaneous microaxial flow pump in the treatment of complex and high-risk indicated patients"}],"physDesc":[{"noteIll":"Illustrationen","extent":"7 S."}],"relHost":[{"title":[{"title":"Catheterization and cardiovascular interventions","subtitle":"official journal of the Society for Cardiac Angiography & Interventions","title_sort":"Catheterization and cardiovascular interventions"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"7","issue":"1","year":"2025","pages":"189-195","volume":"106","text":"106(2025), 1 vom: Juli, Seite 189-195"},"language":["eng"],"pubHistory":["46.1999 -"],"note":["Gesehen am 21.01.04"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"320413004","id":{"issn":["1522-726X"],"eki":["320413004"],"zdb":["2001555-0"],"doi":["10.1002/(ISSN)1522-726X"]},"origin":[{"dateIssuedDisp":"1999-","publisherPlace":"New York, NY","dateIssuedKey":"1999","publisher":"Wiley Interscience"}],"disp":"Safety and efficacy of a plug-based vascular closure device after percutaneous microaxial flow pump in the treatment of complex and high-risk indicated patientsCatheterization and cardiovascular interventions"}]} 
SRT |a SCHROEDERJSAFETYANDE1202