Investigating the shortcomings of the flow convergence method for quantification of mitral regurgitation in a pulsatile in-vitro environment and with computational fluid dynamics

The flow convergence method includes calculation of the proximal isovelocity surface area (PISA) and is widely used to classify mitral regurgitation (MR) with echocardiography. It constitutes a primary decision factor for determination of treatment and should therefore be a robust quantification met...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Leister, Robin (VerfasserIn) , Karl, Roger (VerfasserIn) , Stroh, Lubov (VerfasserIn) , Mereles, Derliz (VerfasserIn) , Eden, Matthias (VerfasserIn) , Neff, Luis (VerfasserIn) , De Simone, Raffaele (VerfasserIn) , Romano, Gabriele (VerfasserIn) , Kriegseis, Jochen (VerfasserIn) , Karck, Matthias (VerfasserIn) , Lichtenstern, Christoph (VerfasserIn) , Frey, Norbert (VerfasserIn) , Frohnapfel, Bettina (VerfasserIn) , Stroh, Alexander (VerfasserIn) , Engelhardt, Sandy (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 06 January 2025
In: Cardiovascular engineering and technology
Year: 2025, Jahrgang: 16, Heft: 2, Pages: 155-170
ISSN:1869-4098
DOI:10.1007/s13239-024-00763-w
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s13239-024-00763-w
Volltext
Verfasserangaben:Robin Leister, Roger Karl, Lubov Stroh, Derliz Mereles, Matthias Eden, Luis Neff, Raffaele de Simone, Gabriele Romano, Jochen Kriegseis, Matthias Karck, Christoph Lichtenstern, Norbert Frey, Bettina Frohnapfel, Alexander Stroh, Sandy Engelhardt

MARC

LEADER 00000naa a2200000 c 4500
001 1938093585
003 DE-627
005 20251009105609.0
007 cr uuu---uuuuu
008 251009s2025 xx |||||o 00| ||eng c
024 7 |a 10.1007/s13239-024-00763-w  |2 doi 
035 |a (DE-627)1938093585 
035 |a (DE-599)KXP1938093585 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Leister, Robin  |e VerfasserIn  |0 (DE-588)1281244619  |0 (DE-627)1836944594  |4 aut 
245 1 0 |a Investigating the shortcomings of the flow convergence method for quantification of mitral regurgitation in a pulsatile in-vitro environment and with computational fluid dynamics  |c Robin Leister, Roger Karl, Lubov Stroh, Derliz Mereles, Matthias Eden, Luis Neff, Raffaele de Simone, Gabriele Romano, Jochen Kriegseis, Matthias Karck, Christoph Lichtenstern, Norbert Frey, Bettina Frohnapfel, Alexander Stroh, Sandy Engelhardt 
264 1 |c 06 January 2025 
300 |a 16 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.10.2025 
520 |a The flow convergence method includes calculation of the proximal isovelocity surface area (PISA) and is widely used to classify mitral regurgitation (MR) with echocardiography. It constitutes a primary decision factor for determination of treatment and should therefore be a robust quantification method. However, it is known for its tendency to underestimate MR and its dependence on user expertise. The present work systematically compares different pulsatile flow profiles arising from different regurgitation orifices using transesophageal echocardiographic (TEE) probe and particle image velocimetry (PIV) as a reference in an in-vitro environment. It is found that the inter-observer variability using echocardiography is small compared to the systematic underestimation of the regurgitation volume for large orifice areas (up to 52%) where a violation of the flow convergence method assumptions occurs. From a flow perspective, a starting vortex was found as a dominant flow pattern in the regurgant jet for all orifice shapes and sizes. A series of simplified computational fluid dynamics (CFD) simulations indicate that selecting a suboptimal aliasing velocity during echocardiography measurements might be a primary source of potential underestimation in MR characterization via the PISA-based method, reaching up to 40%. In this study, it has been noted in clinical observations that physicians often select an aliasing velocity higher than necessary for optimal estimation in diagnostic procedures. 
650 4 |a Computational fluid dynamics 
650 4 |a Flow convergence method 
650 4 |a Mitral regurgitation 
650 4 |a Particle image velocimetry 
650 4 |a Proximal isovelocity surface area 
700 1 |a Karl, Roger  |d 1992-  |e VerfasserIn  |0 (DE-588)1316834492  |0 (DE-627)1878634127  |4 aut 
700 1 |a Stroh, Lubov  |e VerfasserIn  |0 (DE-588)1316835014  |0 (DE-627)1878634917  |4 aut 
700 1 |a Mereles, Derliz  |d 1963-  |e VerfasserIn  |0 (DE-588)129031062  |0 (DE-627)387883754  |0 (DE-576)297456970  |4 aut 
700 1 |a Eden, Matthias  |d 1978-  |e VerfasserIn  |0 (DE-588)135799740  |0 (DE-627)571282474  |0 (DE-576)300652879  |4 aut 
700 1 |a Neff, Luis  |e VerfasserIn  |4 aut 
700 1 |a De Simone, Raffaele  |d 1958-  |e VerfasserIn  |0 (DE-588)1075518466  |0 (DE-627)833385674  |0 (DE-576)443621667  |4 aut 
700 1 |a Romano, Gabriele  |d 1991-  |e VerfasserIn  |0 (DE-588)1204102082  |0 (DE-627)168924464X  |4 aut 
700 1 |a Kriegseis, Jochen  |d 1977-  |e VerfasserIn  |0 (DE-588)1018036067  |0 (DE-627)690497814  |0 (DE-576)354834533  |4 aut 
700 1 |a Karck, Matthias  |d 1961-  |e VerfasserIn  |0 (DE-588)130833525  |0 (DE-627)505909340  |0 (DE-576)298366169  |4 aut 
700 1 |a Lichtenstern, Christoph  |d 1974-  |e VerfasserIn  |0 (DE-588)130446696  |0 (DE-627)501840702  |0 (DE-576)298200597  |4 aut 
700 1 |a Frey, Norbert  |e VerfasserIn  |0 (DE-588)141244976  |0 (DE-627)625824075  |0 (DE-576)322969514  |4 aut 
700 1 |a Frohnapfel, Bettina  |d 1978-  |e VerfasserIn  |0 (DE-588)133269396  |0 (DE-627)53965051X  |0 (DE-576)299738582  |4 aut 
700 1 |a Stroh, Alexander  |e VerfasserIn  |0 (DE-588)1119182522  |0 (DE-627)872491382  |0 (DE-576)47977207X  |4 aut 
700 1 |a Engelhardt, Sandy  |d 1987-  |e VerfasserIn  |0 (DE-588)1122674465  |0 (DE-627)876003080  |0 (DE-576)481436049  |4 aut 
773 0 8 |i Enthalten in  |t Cardiovascular engineering and technology  |d New York, NY : Springer, 2010  |g 16(2025), 2, Seite 155-170  |h Online-Ressource  |w (DE-627)620775289  |w (DE-600)2543111-0  |w (DE-576)320937666  |x 1869-4098  |7 nnas  |a Investigating the shortcomings of the flow convergence method for quantification of mitral regurgitation in a pulsatile in-vitro environment and with computational fluid dynamics 
773 1 8 |g volume:16  |g year:2025  |g number:2  |g pages:155-170  |g extent:16  |a Investigating the shortcomings of the flow convergence method for quantification of mitral regurgitation in a pulsatile in-vitro environment and with computational fluid dynamics 
856 4 0 |u https://doi.org/10.1007/s13239-024-00763-w  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20251009 
993 |a Article 
994 |a 2025 
998 |g 1122674465  |a Engelhardt, Sandy  |m 1122674465:Engelhardt, Sandy  |d 910000  |d 910100  |e 910000PE1122674465  |e 910100PE1122674465  |k 0/910000/  |k 1/910000/910100/  |p 15  |y j 
998 |g 141244976  |a Frey, Norbert  |m 141244976:Frey, Norbert  |d 910000  |d 910100  |e 910000PF141244976  |e 910100PF141244976  |k 0/910000/  |k 1/910000/910100/  |p 12 
998 |g 130446696  |a Lichtenstern, Christoph  |m 130446696:Lichtenstern, Christoph  |d 910000  |d 910300  |d 50000  |e 910000PL130446696  |e 910300PL130446696  |e 50000PL130446696  |k 0/910000/  |k 1/910000/910300/  |k 0/50000/  |p 11 
998 |g 130833525  |a Karck, Matthias  |m 130833525:Karck, Matthias  |d 910000  |d 910200  |e 910000PK130833525  |e 910200PK130833525  |k 0/910000/  |k 1/910000/910200/  |p 10 
998 |g 1204102082  |a Romano, Gabriele  |m 1204102082:Romano, Gabriele  |d 910000  |d 910200  |e 910000PR1204102082  |e 910200PR1204102082  |k 0/910000/  |k 1/910000/910200/  |p 8 
998 |g 1075518466  |a De Simone, Raffaele  |m 1075518466:De Simone, Raffaele  |d 910000  |d 910200  |d 50000  |e 910000PD1075518466  |e 910200PD1075518466  |e 50000PD1075518466  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 7 
998 |g 135799740  |a Eden, Matthias  |m 135799740:Eden, Matthias  |d 910000  |d 910100  |e 910000PE135799740  |e 910100PE135799740  |k 0/910000/  |k 1/910000/910100/  |p 5 
998 |g 129031062  |a Mereles, Derliz  |m 129031062:Mereles, Derliz  |d 910000  |d 910100  |e 910000PM129031062  |e 910100PM129031062  |k 0/910000/  |k 1/910000/910100/  |p 4 
998 |g 1316835014  |a Stroh, Lubov  |m 1316835014:Stroh, Lubov  |d 910000  |d 910300  |e 910000PS1316835014  |e 910300PS1316835014  |k 0/910000/  |k 1/910000/910300/  |p 3 
998 |g 1316834492  |a Karl, Roger  |m 1316834492:Karl, Roger  |d 50000  |d 51001  |e 50000PK1316834492  |e 51001PK1316834492  |k 0/50000/  |k 1/50000/51001/  |p 2 
999 |a KXP-PPN1938093585  |e 4783527091 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Robin Leister, Roger Karl, Lubov Stroh, Derliz Mereles, Matthias Eden, Luis Neff, Raffaele de Simone, Gabriele Romano, Jochen Kriegseis, Matthias Karck, Christoph Lichtenstern, Norbert Frey, Bettina Frohnapfel, Alexander Stroh, Sandy Engelhardt"]},"id":{"eki":["1938093585"],"doi":["10.1007/s13239-024-00763-w"]},"origin":[{"dateIssuedDisp":"06 January 2025","dateIssuedKey":"2025"}],"person":[{"given":"Robin","role":"aut","family":"Leister","display":"Leister, Robin"},{"display":"Karl, Roger","role":"aut","given":"Roger","family":"Karl"},{"family":"Stroh","role":"aut","given":"Lubov","display":"Stroh, Lubov"},{"display":"Mereles, Derliz","family":"Mereles","role":"aut","given":"Derliz"},{"given":"Matthias","role":"aut","family":"Eden","display":"Eden, Matthias"},{"display":"Neff, Luis","given":"Luis","role":"aut","family":"Neff"},{"given":"Raffaele","role":"aut","family":"De Simone","display":"De Simone, Raffaele"},{"display":"Romano, Gabriele","given":"Gabriele","role":"aut","family":"Romano"},{"family":"Kriegseis","given":"Jochen","role":"aut","display":"Kriegseis, Jochen"},{"display":"Karck, Matthias","given":"Matthias","role":"aut","family":"Karck"},{"family":"Lichtenstern","role":"aut","given":"Christoph","display":"Lichtenstern, Christoph"},{"display":"Frey, Norbert","given":"Norbert","role":"aut","family":"Frey"},{"display":"Frohnapfel, Bettina","family":"Frohnapfel","role":"aut","given":"Bettina"},{"family":"Stroh","given":"Alexander","role":"aut","display":"Stroh, Alexander"},{"role":"aut","given":"Sandy","family":"Engelhardt","display":"Engelhardt, Sandy"}],"relHost":[{"disp":"Investigating the shortcomings of the flow convergence method for quantification of mitral regurgitation in a pulsatile in-vitro environment and with computational fluid dynamicsCardiovascular engineering and technology","physDesc":[{"extent":"Online-Ressource"}],"recId":"620775289","language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"title":[{"title":"Cardiovascular engineering and technology","title_sort":"Cardiovascular engineering and technology","subtitle":"CVET"}],"origin":[{"publisher":"Springer","publisherPlace":"New York, NY","dateIssuedKey":"2010","dateIssuedDisp":"2010-"}],"part":{"pages":"155-170","issue":"2","extent":"16","text":"16(2025), 2, Seite 155-170","year":"2025","volume":"16"},"id":{"eki":["620775289"],"issn":["1869-4098"],"zdb":["2543111-0"]},"pubHistory":["2010 -"],"titleAlt":[{"title":"CVET"}],"name":{"displayForm":["Biomedical Engineering Society"]}}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"note":["Gesehen am 09.10.2025"],"title":[{"title_sort":"Investigating the shortcomings of the flow convergence method for quantification of mitral regurgitation in a pulsatile in-vitro environment and with computational fluid dynamics","title":"Investigating the shortcomings of the flow convergence method for quantification of mitral regurgitation in a pulsatile in-vitro environment and with computational fluid dynamics"}],"physDesc":[{"extent":"16 S."}],"recId":"1938093585"} 
SRT |a LEISTERROBINVESTIGAT0620