Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa

BackgroundConsumer-grade wearables are becoming increasingly popular in research and in clinical contexts. These technologies hold significant promise for advancing digital medicine, particularly in remote and rural areas in low-income settings like sub-Saharan Africa, where climate change is exacer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mendt, Stefan (VerfasserIn) , Zout, Georgi (VerfasserIn) , Rabuffetti, Marco (VerfasserIn) , Gunga, Hanns-Christian (VerfasserIn) , Bunker, Aditi (VerfasserIn) , Barteit, Sandra (VerfasserIn) , Maggioni, Martina Anna (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 13 February 2025
In: Frontiers in physiology
Year: 2025, Jahrgang: 16, Pages: 1-12
ISSN:1664-042X
DOI:10.3389/fphys.2025.1491401
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.3389/fphys.2025.1491401
Verlag, kostenfrei, Volltext: https://www.frontiersin.org/journals/physiology/articles/10.3389/fphys.2025.1491401/full
Volltext
Verfasserangaben:Stefan Mendt, Georgi Zout, Marco Rabuffetti, Hanns-Christian Gunga, Aditi Bunker, Sandra Barteit and Martina Anna Maggioni

MARC

LEADER 00000naa a2200000 c 4500
001 193827492X
003 DE-627
005 20251013101856.0
007 cr uuu---uuuuu
008 251013s2025 xx |||||o 00| ||eng c
024 7 |a 10.3389/fphys.2025.1491401  |2 doi 
035 |a (DE-627)193827492X 
035 |a (DE-599)KXP193827492X 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Mendt, Stefan  |e VerfasserIn  |0 (DE-588)1280309059  |0 (DE-627)1833408683  |4 aut 
245 1 0 |a Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa  |c Stefan Mendt, Georgi Zout, Marco Rabuffetti, Hanns-Christian Gunga, Aditi Bunker, Sandra Barteit and Martina Anna Maggioni 
264 1 |c 13 February 2025 
300 |b Illustrationen 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 13.10.2025 
520 |a BackgroundConsumer-grade wearables are becoming increasingly popular in research and in clinical contexts. These technologies hold significant promise for advancing digital medicine, particularly in remote and rural areas in low-income settings like sub-Saharan Africa, where climate change is exacerbating health risks. This study evaluates the data agreement between consumer-grade and research-established devices under standardized conditions.MethodsTwenty-two participants (11 women, 11 men) performed a structured protocol, consisting of six different activity phases (sitting, standing, and the first four stages of the classic Bruce treadmill test). We collected heart rate, (core) body temperature, step count, and energy expenditure. Each variable was simultaneously tracked by consumer-grade and established research-grade devices to evaluate the validity of the consumer-grade devices. We statistically compared the data agreement using Pearson’s correlation r, Lin’s concordance correlation coefficient (LCCC), Bland-Altman method, and mean absolute percentage error.ResultsA good agreement was found between the wrist-worn Withings Pulse HR (consumer-grade) and the chest-worn Faros Bittium 180 in measuring heart rate while sitting, standing, and slow walking on a treadmill at a speed of 2.7 km/h (r ≥ 0.82, |bias| ≤ 3.1 bpm), but this decreased with increasing speed (r ≤ 0.33, |bias| ≤ 11.7 bpm). The agreement between the Withing device and the research-established device worn on the wrist (GENEActiv) for measuring the number of steps also decreased during the treadmill phases (first stage: r = 0.48, bias = 0.6 steps/min; fourth stage: r = 0.48, bias = 17.3 steps/min). Energy expenditure agreement between the Withings device and the indirect calorimetry method was poor during the treadmill test (|r| ≤ 0.29, |bias | ≥ 1.7 MET). The Tucky thermometer under the armpit (consumer-grade) and the Tcore sensor on the forehead were found to be in poor agreement in measuring (core) body temperature during resting phases (r ≤ 0.53, |bias| ≥ 0.8°C) and deteriorated during the treadmill test.ConclusionThe Withings device showed adequate performance for heart rate at low activity levels and step count at higher activity levels, but had limited overall accuracy. The Tucky device showed poor agreement with the Tcore in all six different activity phases. The limited accuracy of consumer-grade devices suggests caution in their use for rigorous research, but points to their potential utility in capture general physiological trends in long-term field monitoring or population-health surveillance. 
650 4 |a accelerometer 
650 4 |a fitness tracker 
650 4 |a global health 
650 4 |a heat stress 
650 4 |a physiological parameters 
650 4 |a SSA 
700 1 |a Zout, Georgi  |e VerfasserIn  |4 aut 
700 1 |a Rabuffetti, Marco  |e VerfasserIn  |4 aut 
700 1 |a Gunga, Hanns-Christian  |d 1954-  |e VerfasserIn  |0 (DE-588)138736359  |0 (DE-627)703087649  |0 (DE-576)308864468  |4 aut 
700 1 |a Bunker, Aditi  |d 1985-  |e VerfasserIn  |0 (DE-588)112755316X  |0 (DE-627)881960675  |0 (DE-576)485239337  |4 aut 
700 1 |a Barteit, Sandra  |e VerfasserIn  |0 (DE-588)106930607X  |0 (DE-627)821647288  |0 (DE-576)428577954  |4 aut 
700 1 |a Maggioni, Martina Anna  |e VerfasserIn  |0 (DE-588)1239315678  |0 (DE-627)1767403887  |4 aut 
773 0 8 |i Enthalten in  |t Frontiers in physiology  |d Lausanne : Frontiers Research Foundation, 2007  |g 16(2025), Artikel-ID 1491401, Seite 1-12  |h Online-Ressource  |w (DE-627)631498788  |w (DE-600)2564217-0  |w (DE-576)32655095X  |x 1664-042X  |7 nnas  |a Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa 
773 1 8 |g volume:16  |g year:2025  |g elocationid:1491401  |g pages:1-12  |g extent:12  |a Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa 
856 4 0 |u https://doi.org/10.3389/fphys.2025.1491401  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.frontiersin.org/journals/physiology/articles/10.3389/fphys.2025.1491401/full  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20251013 
993 |a Article 
994 |a 2025 
998 |g 106930607X  |a Barteit, Sandra  |m 106930607X:Barteit, Sandra  |d 910000  |d 912800  |e 910000PB106930607X  |e 912800PB106930607X  |k 0/910000/  |k 1/910000/912800/  |p 6 
998 |g 112755316X  |a Bunker, Aditi  |m 112755316X:Bunker, Aditi  |d 910000  |d 912800  |e 910000PB112755316X  |e 912800PB112755316X  |k 0/910000/  |k 1/910000/912800/  |p 5 
999 |a KXP-PPN193827492X  |e 4786554863 
BIB |a Y 
SER |a journal 
JSO |a {"physDesc":[{"noteIll":"Illustrationen","extent":"12 S."}],"person":[{"roleDisplay":"VerfasserIn","family":"Mendt","given":"Stefan","role":"aut","display":"Mendt, Stefan"},{"given":"Georgi","display":"Zout, Georgi","role":"aut","family":"Zout","roleDisplay":"VerfasserIn"},{"given":"Marco","role":"aut","display":"Rabuffetti, Marco","roleDisplay":"VerfasserIn","family":"Rabuffetti"},{"display":"Gunga, Hanns-Christian","role":"aut","given":"Hanns-Christian","family":"Gunga","roleDisplay":"VerfasserIn"},{"family":"Bunker","roleDisplay":"VerfasserIn","role":"aut","display":"Bunker, Aditi","given":"Aditi"},{"family":"Barteit","roleDisplay":"VerfasserIn","role":"aut","display":"Barteit, Sandra","given":"Sandra"},{"family":"Maggioni","roleDisplay":"VerfasserIn","given":"Martina Anna","role":"aut","display":"Maggioni, Martina Anna"}],"note":["Gesehen am 13.10.2025"],"origin":[{"dateIssuedDisp":"13 February 2025","dateIssuedKey":"2025"}],"id":{"eki":["193827492X"],"doi":["10.3389/fphys.2025.1491401"]},"relHost":[{"name":{"displayForm":["Frontiers Research Foundation"]},"part":{"pages":"1-12","text":"16(2025), Artikel-ID 1491401, Seite 1-12","volume":"16","extent":"12","year":"2025"},"type":{"media":"Online-Ressource","bibl":"periodical"},"language":["eng"],"pubHistory":["2007 -"],"recId":"631498788","disp":"Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan AfricaFrontiers in physiology","title":[{"title_sort":"Frontiers in physiology","title":"Frontiers in physiology"}],"origin":[{"dateIssuedKey":"2007","publisher":"Frontiers Research Foundation","dateIssuedDisp":"2007-","publisherPlace":"Lausanne"}],"id":{"zdb":["2564217-0"],"issn":["1664-042X"],"eki":["631498788"]},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 24.05.23"]}],"recId":"193827492X","title":[{"title":"Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa","title_sort":"Laboratory comparison of consumer-grade and research-established wearables for monitoring heart rate, body temperature, and physical acitivity in sub-Saharan Africa"}],"name":{"displayForm":["Stefan Mendt, Georgi Zout, Marco Rabuffetti, Hanns-Christian Gunga, Aditi Bunker, Sandra Barteit and Martina Anna Maggioni"]},"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"}} 
SRT |a MENDTSTEFALABORATORY1320