Design of a large area digital SiPM with high fill factor and fully serial digital readout for single photon detection in liquid noble gas detectors

We present a 'digital SiPM' photo-detection chip combining single photon sensitive avalanche photo diodes and CMOS readout electronics on a single die. The chip has a size of 8046× 9032 μm2 with 72.5% of photo sensitive area. It is subdivided into 32 × 30 pixels with an average size of 250...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fischer, Peter (VerfasserIn) , Keller, Michael (VerfasserIn) , Ritzert, Michael (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: June 2025
In: Journal of Instrumentation
Year: 2025, Jahrgang: 20, Heft: 6, Pages: 1-18
ISSN:1748-0221
DOI:10.1088/1748-0221/20/06/C06008
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1088/1748-0221/20/06/C06008
Volltext
Verfasserangaben:Peter Fischer, Michael Keller and Michael Ritzert

MARC

LEADER 00000caa a2200000 c 4500
001 193844888X
003 DE-627
005 20251020102801.0
007 cr uuu---uuuuu
008 251015s2025 xx |||||o 00| ||eng c
024 7 |a 10.1088/1748-0221/20/06/C06008  |2 doi 
035 |a (DE-627)193844888X 
035 |a (DE-599)KXP193844888X 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 28  |2 sdnb 
100 1 |a Fischer, Peter  |d 1961-  |e VerfasserIn  |0 (DE-588)130634468  |0 (DE-627)707540682  |0 (DE-576)301221553  |4 aut 
245 1 0 |a Design of a large area digital SiPM with high fill factor and fully serial digital readout for single photon detection in liquid noble gas detectors  |c Peter Fischer, Michael Keller and Michael Ritzert 
264 1 |c June 2025 
300 |b Illustrationen 
300 |a 18 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 9. Juni 2025 
500 |a Gesehen am 15.10.2025 
520 |a We present a 'digital SiPM' photo-detection chip combining single photon sensitive avalanche photo diodes and CMOS readout electronics on a single die. The chip has a size of 8046× 9032 μm2 with 72.5% of photo sensitive area. It is subdivided into 32 × 30 pixels with an average size of 250×291 μm2. For each photon hit, the chip records the pixel coordinate and the arrival time with a granularity of ≈ 10 ns. Readout and chip control are purely digital, requiring only 4 CMOS signals. Several chips can be daisy chained and grouped on larger modules so that detector planes with ≈ 70% photo sensitive area can be build. Our chip may be used in experiments that need to detect rare scintillation events, for instance dark matter searches using liquid noble gases. 
700 1 |a Keller, Michael  |d 1992-  |e VerfasserIn  |0 (DE-588)1164809334  |0 (DE-627)1029130167  |0 (DE-576)510153135  |4 aut 
700 1 |a Ritzert, Michael  |e VerfasserIn  |0 (DE-588)1054166102  |0 (DE-627)791117987  |0 (DE-576)41004783X  |4 aut 
773 0 8 |i Enthalten in  |t Journal of Instrumentation  |d London : Inst. of Physics, 2006  |g 20(2025), 6 vom: Juni, Artikel-ID C06008, Seite 1-18  |h Online-Ressource  |w (DE-627)512298181  |w (DE-600)2235672-1  |w (DE-576)256442541  |x 1748-0221  |7 nnas  |a Design of a large area digital SiPM with high fill factor and fully serial digital readout for single photon detection in liquid noble gas detectors 
773 1 8 |g volume:20  |g year:2025  |g number:6  |g month:06  |g elocationid:C06008  |g pages:1-18  |g extent:18  |a Design of a large area digital SiPM with high fill factor and fully serial digital readout for single photon detection in liquid noble gas detectors 
856 4 0 |u https://doi.org/10.1088/1748-0221/20/06/C06008  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20251015 
993 |a Article 
994 |a 2025 
998 |g 1054166102  |a Ritzert, Michael  |m 1054166102:Ritzert, Michael  |d 130000  |d 130200  |e 130000PR1054166102  |e 130200PR1054166102  |k 0/130000/  |k 1/130000/130200/  |p 3  |y j 
998 |g 1164809334  |a Keller, Michael  |m 1164809334:Keller, Michael  |d 700000  |d 720000  |e 700000PK1164809334  |e 720000PK1164809334  |k 0/700000/  |k 1/700000/720000/  |p 2 
998 |g 130634468  |a Fischer, Peter  |m 130634468:Fischer, Peter  |d 700000  |d 720000  |e 700000PF130634468  |e 720000PF130634468  |k 0/700000/  |k 1/700000/720000/  |p 1  |x j 
999 |a KXP-PPN193844888X  |e 4787657925 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Veröffentlicht: 9. Juni 2025","Gesehen am 15.10.2025"],"relHost":[{"origin":[{"dateIssuedDisp":"2006-","publisher":"Inst. of Physics","dateIssuedKey":"2006","publisherPlace":"London"}],"physDesc":[{"extent":"Online-Ressource"}],"part":{"issue":"6","year":"2025","text":"20(2025), 6 vom: Juni, Artikel-ID C06008, Seite 1-18","volume":"20","pages":"1-18","extent":"18"},"type":{"bibl":"periodical","media":"Online-Ressource"},"pubHistory":["1.2006 -"],"language":["eng"],"name":{"displayForm":["Institute of Physics Publishing"]},"title":[{"title_sort":"Journal of Instrumentation","title":"Journal of Instrumentation"}],"disp":"Design of a large area digital SiPM with high fill factor and fully serial digital readout for single photon detection in liquid noble gas detectorsJournal of Instrumentation","id":{"issn":["1748-0221"],"eki":["512298181"],"zdb":["2235672-1"]},"recId":"512298181","note":["Gesehen am 02.11.2020"]}],"recId":"193844888X","person":[{"given":"Peter","role":"aut","roleDisplay":"VerfasserIn","display":"Fischer, Peter","family":"Fischer"},{"family":"Keller","display":"Keller, Michael","role":"aut","roleDisplay":"VerfasserIn","given":"Michael"},{"family":"Ritzert","display":"Ritzert, Michael","roleDisplay":"VerfasserIn","role":"aut","given":"Michael"}],"id":{"doi":["10.1088/1748-0221/20/06/C06008"],"eki":["193844888X"]},"title":[{"title_sort":"Design of a large area digital SiPM with high fill factor and fully serial digital readout for single photon detection in liquid noble gas detectors","title":"Design of a large area digital SiPM with high fill factor and fully serial digital readout for single photon detection in liquid noble gas detectors"}],"name":{"displayForm":["Peter Fischer, Michael Keller and Michael Ritzert"]},"language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"18 S.","noteIll":"Illustrationen"}],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"June 2025"}]} 
SRT |a FISCHERPETDESIGNOFAL2025