Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantom
Background Ion-beam radiography is a promising technique to verify the range of ion-beam radiotherapy treatments regularly. To detect and quantify the water-equivalent thickness (WET) of potential anatomical changes, ion-beam radiographs must provide a sufficient WET accuracy on the level of 1%. Pur...
Saved in:
| Main Authors: | , , , , , , , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
June 2025
|
| In: |
Medical physics
Year: 2025, Volume: 52, Issue: 6, Pages: 4757-4768 |
| ISSN: | 2473-4209 |
| DOI: | 10.1002/mp.17786 |
| Online Access: | Verlag, kostenfrei, Volltext: https://doi.org/10.1002/mp.17786 Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.17786 |
| Author Notes: | Margareta Metzner, Friderike K. Longarino, Benjamin Ackermann, Annika Schlechter, Maike Saphörster, Yanting Xu, Julian Schlecker, Patrick Wohlfahrt, Christian Richter, Stephan Brons, Jürgen Debus, Oliver Jäkel, Mária Martišíková, Tim Gehrke |
| Summary: | Background Ion-beam radiography is a promising technique to verify the range of ion-beam radiotherapy treatments regularly. To detect and quantify the water-equivalent thickness (WET) of potential anatomical changes, ion-beam radiographs must provide a sufficient WET accuracy on the level of 1%. Purpose In this work, we show an energy-painted helium-beam radiograph of an anthropomorphic head phantom acquired with thin silicon pixel detectors for the first time. Furthermore, we determine the WET accuracy of our helium-beam radiography system for the especially heterogeneous skull base region, which is highly relevant for the treatment of head and neck and skull base tumors. Methods With a detection system based on pixelated semiconducting Timepix detectors, we track single ions upstream and downstream of the head phantom. Furthermore, we measure their energy deposition in a thin Timepix detector behind the anthropomorphic phantom. To ensure a high precision of the image, we acquired a radiograph by using helium beams with five initial energies between 146.84 and 188.07 MeV/u following the energy painting algorithm. With a Siemens SOMATOM Confidence CT scanner, a single- and dual-energy CT were acquired with clinical protocols and translated to relative stopping power (RSP) values. After projecting these scans, the resulting WET maps were compared to the helium-beam radiograph. To evaluate the accuracy of all three modalities, a reference data set based on range-pullback measurements and a segmentation of a high-resolution CT scan was taken into account. Results The mean absolute percentage error (MAPE) of all modalities was determined to be between 0.95% and 1.16%. Also, the root-mean-square percentage error (RMSPE) was similar for all modalities ranging from 1.19% to 1.46%. These deviations from the reference scan were found to mainly stem from an overestimation of air and sinus tissue and underestimation of cortical bone. Conclusions The helium-beam radiograph was shown to achieve a WET accuracy competitive with that of clinically used imaging methods. If certain technical aspects are addressed, helium-beam radiography may emerge as an auspicious imaging modality for on-couch range verification of ion-beam radiotherapy treatments allowing for regular detection and quantification of anatomical changes. |
|---|---|
| Item Description: | Online veröffentlicht: 26. März 2025 Gesehen am 05.11.2025 |
| Physical Description: | Online Resource |
| ISSN: | 2473-4209 |
| DOI: | 10.1002/mp.17786 |