Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantom

Background Ion-beam radiography is a promising technique to verify the range of ion-beam radiotherapy treatments regularly. To detect and quantify the water-equivalent thickness (WET) of potential anatomical changes, ion-beam radiographs must provide a sufficient WET accuracy on the level of 1%. Pur...

Full description

Saved in:
Bibliographic Details
Main Authors: Metzner, Margareta (Author) , Longarino, Friderike (Author) , Ackermann, Benjamin (Author) , Schlechter, Annika (Author) , Saphörster, Maike (Author) , Xu, Yanting (Author) , Schlecker, Julian (Author) , Wohlfahrt, Patrick (Author) , Richter, Christian (Author) , Brons, Stephan (Author) , Debus, Jürgen (Author) , Jäkel, Oliver (Author) , Martišíková, Mária (Author) , Gehrke, Tim (Author)
Format: Article (Journal)
Language:English
Published: June 2025
In: Medical physics
Year: 2025, Volume: 52, Issue: 6, Pages: 4757-4768
ISSN:2473-4209
DOI:10.1002/mp.17786
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1002/mp.17786
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.17786
Get full text
Author Notes:Margareta Metzner, Friderike K. Longarino, Benjamin Ackermann, Annika Schlechter, Maike Saphörster, Yanting Xu, Julian Schlecker, Patrick Wohlfahrt, Christian Richter, Stephan Brons, Jürgen Debus, Oliver Jäkel, Mária Martišíková, Tim Gehrke

MARC

LEADER 00000caa a22000002c 4500
001 1940323665
003 DE-627
005 20251209032824.0
007 cr uuu---uuuuu
008 251105s2025 xx |||||o 00| ||eng c
024 7 |a 10.1002/mp.17786  |2 doi 
035 |a (DE-627)1940323665 
035 |a (DE-599)KXP1940323665 
035 |a (OCoLC)1559714097 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Metzner, Margareta  |d 1996-  |e VerfasserIn  |0 (DE-588)1336875674  |0 (DE-627)1896452337  |4 aut 
245 1 0 |a Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantom  |c Margareta Metzner, Friderike K. Longarino, Benjamin Ackermann, Annika Schlechter, Maike Saphörster, Yanting Xu, Julian Schlecker, Patrick Wohlfahrt, Christian Richter, Stephan Brons, Jürgen Debus, Oliver Jäkel, Mária Martišíková, Tim Gehrke 
264 1 |c June 2025 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online veröffentlicht: 26. März 2025 
500 |a Gesehen am 05.11.2025 
520 |a Background Ion-beam radiography is a promising technique to verify the range of ion-beam radiotherapy treatments regularly. To detect and quantify the water-equivalent thickness (WET) of potential anatomical changes, ion-beam radiographs must provide a sufficient WET accuracy on the level of 1%. Purpose In this work, we show an energy-painted helium-beam radiograph of an anthropomorphic head phantom acquired with thin silicon pixel detectors for the first time. Furthermore, we determine the WET accuracy of our helium-beam radiography system for the especially heterogeneous skull base region, which is highly relevant for the treatment of head and neck and skull base tumors. Methods With a detection system based on pixelated semiconducting Timepix detectors, we track single ions upstream and downstream of the head phantom. Furthermore, we measure their energy deposition in a thin Timepix detector behind the anthropomorphic phantom. To ensure a high precision of the image, we acquired a radiograph by using helium beams with five initial energies between 146.84 and 188.07 MeV/u following the energy painting algorithm. With a Siemens SOMATOM Confidence CT scanner, a single- and dual-energy CT were acquired with clinical protocols and translated to relative stopping power (RSP) values. After projecting these scans, the resulting WET maps were compared to the helium-beam radiograph. To evaluate the accuracy of all three modalities, a reference data set based on range-pullback measurements and a segmentation of a high-resolution CT scan was taken into account. Results The mean absolute percentage error (MAPE) of all modalities was determined to be between 0.95% and 1.16%. Also, the root-mean-square percentage error (RMSPE) was similar for all modalities ranging from 1.19% to 1.46%. These deviations from the reference scan were found to mainly stem from an overestimation of air and sinus tissue and underestimation of cortical bone. Conclusions The helium-beam radiograph was shown to achieve a WET accuracy competitive with that of clinically used imaging methods. If certain technical aspects are addressed, helium-beam radiography may emerge as an auspicious imaging modality for on-couch range verification of ion-beam radiotherapy treatments allowing for regular detection and quantification of anatomical changes. 
650 4 |a ion-beam imaging 
650 4 |a proton therapy 
650 4 |a timepix detectors 
700 1 |a Longarino, Friderike  |d 1996-  |e VerfasserIn  |0 (DE-588)126821874X  |0 (DE-627)1816771821  |4 aut 
700 1 |a Ackermann, Benjamin  |d 1979-  |e VerfasserIn  |0 (DE-588)1066758417  |0 (DE-627)817931562  |0 (DE-576)426134141  |4 aut 
700 1 |a Schlechter, Annika  |e VerfasserIn  |0 (DE-588)1253305919  |0 (DE-627)1795362227  |4 aut 
700 1 |a Saphörster, Maike  |e VerfasserIn  |4 aut 
700 1 |a Xu, Yanting  |e VerfasserIn  |4 aut 
700 1 |a Schlecker, Julian  |e VerfasserIn  |4 aut 
700 1 |a Wohlfahrt, Patrick  |e VerfasserIn  |4 aut 
700 1 |a Richter, Christian  |e VerfasserIn  |4 aut 
700 1 |a Brons, Stephan  |e VerfasserIn  |0 (DE-588)1072782375  |0 (DE-627)828233594  |0 (DE-576)434240478  |4 aut 
700 1 |a Debus, Jürgen  |d 1964-  |e VerfasserIn  |0 (DE-588)1022671421  |0 (DE-627)717025780  |0 (DE-576)365774944  |4 aut 
700 1 |a Jäkel, Oliver  |d 1964-  |e VerfasserIn  |0 (DE-588)1050056302  |0 (DE-627)783260709  |0 (DE-576)404358705  |4 aut 
700 1 |a Martišíková, Mária  |d 1979-  |e VerfasserIn  |0 (DE-588)1076839649  |0 (DE-627)835386767  |0 (DE-576)252899369  |4 aut 
700 1 |a Gehrke, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1044696982  |0 (DE-627)772571627  |0 (DE-576)398073740  |4 aut 
773 0 8 |i Enthalten in  |t Medical physics  |d Hoboken, NJ : Wiley, 1974  |g 52(2025), 6 vom: Juni, Seite 4757-4768  |h Online-Ressource  |w (DE-627)265784867  |w (DE-600)1466421-5  |w (DE-576)074891243  |x 2473-4209  |7 nnas  |a Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantom 
773 1 8 |g volume:52  |g year:2025  |g number:6  |g month:06  |g pages:4757-4768  |g extent:12  |a Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantom 
856 4 0 |u https://doi.org/10.1002/mp.17786  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext  |7 0 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/mp.17786  |x Verlag  |z kostenfrei  |3 Volltext  |7 0 
951 |a AR 
992 |a 20251105 
993 |a Article 
994 |a 2025 
998 |g 1044696982  |a Gehrke, Tim  |m 1044696982:Gehrke, Tim  |d 910000  |d 911400  |e 910000PG1044696982  |e 911400PG1044696982  |k 0/910000/  |k 1/910000/911400/  |p 14  |y j 
998 |g 1076839649  |a Martišíková, Mária  |m 1076839649:Martišíková, Mária  |d 50000  |e 50000PM1076839649  |k 0/50000/  |p 13 
998 |g 1050056302  |a Jäkel, Oliver  |m 1050056302:Jäkel, Oliver  |d 50000  |e 50000PJ1050056302  |k 0/50000/  |p 12 
998 |g 1022671421  |a Debus, Jürgen  |m 1022671421:Debus, Jürgen  |d 910000  |d 911400  |e 910000PD1022671421  |e 911400PD1022671421  |k 0/910000/  |k 1/910000/911400/  |p 11 
998 |g 1336875674  |a Metzner, Margareta  |m 1336875674:Metzner, Margareta  |d 130000  |e 130000PM1336875674  |k 0/130000/  |p 1  |x j 
999 |a KXP-PPN1940323665  |e 4797075341 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Online veröffentlicht: 26. März 2025","Gesehen am 05.11.2025"],"relHost":[{"part":{"extent":"12","text":"52(2025), 6 vom: Juni, Seite 4757-4768","pages":"4757-4768","volume":"52","issue":"6","year":"2025"},"id":{"eki":["265784867"],"zdb":["1466421-5"],"issn":["2473-4209","1522-8541"]},"origin":[{"publisherPlace":"Hoboken, NJ ; College Park, Md. ; New York, NY","dateIssuedDisp":"1974-","dateIssuedKey":"1974","publisher":"Wiley ; AAPM ; [Verlag nicht ermittelbar]"}],"disp":"Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantomMedical physics","name":{"displayForm":["American Association of Physicists in Medicine ; American Institute of Physics"]},"recId":"265784867","title":[{"title":"Medical physics","title_sort":"Medical physics"}],"pubHistory":["1.1974 -"],"language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 01.08.2025"],"titleAlt":[{"title":"Medical physics online"}]}],"physDesc":[{"extent":"12 S."}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"person":[{"display":"Metzner, Margareta","role":"aut","given":"Margareta","family":"Metzner"},{"given":"Friderike","role":"aut","family":"Longarino","display":"Longarino, Friderike"},{"family":"Ackermann","given":"Benjamin","role":"aut","display":"Ackermann, Benjamin"},{"display":"Schlechter, Annika","role":"aut","given":"Annika","family":"Schlechter"},{"display":"Saphörster, Maike","role":"aut","given":"Maike","family":"Saphörster"},{"display":"Xu, Yanting","family":"Xu","role":"aut","given":"Yanting"},{"given":"Julian","role":"aut","family":"Schlecker","display":"Schlecker, Julian"},{"display":"Wohlfahrt, Patrick","given":"Patrick","role":"aut","family":"Wohlfahrt"},{"display":"Richter, Christian","role":"aut","given":"Christian","family":"Richter"},{"display":"Brons, Stephan","family":"Brons","role":"aut","given":"Stephan"},{"family":"Debus","given":"Jürgen","role":"aut","display":"Debus, Jürgen"},{"display":"Jäkel, Oliver","family":"Jäkel","given":"Oliver","role":"aut"},{"family":"Martišíková","role":"aut","given":"Mária","display":"Martišíková, Mária"},{"family":"Gehrke","given":"Tim","role":"aut","display":"Gehrke, Tim"}],"title":[{"title_sort":"Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantom","title":"Accuracy of a helium-beam radiography system based on thin pixel detectors for an anthropomorphic head phantom"}],"name":{"displayForm":["Margareta Metzner, Friderike K. Longarino, Benjamin Ackermann, Annika Schlechter, Maike Saphörster, Yanting Xu, Julian Schlecker, Patrick Wohlfahrt, Christian Richter, Stephan Brons, Jürgen Debus, Oliver Jäkel, Mária Martišíková, Tim Gehrke"]},"recId":"1940323665","id":{"doi":["10.1002/mp.17786"],"eki":["1940323665"]},"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"June 2025"}]} 
SRT |a METZNERMARACCURACYOF2025