The influence of reaming velocity during preparation of the femoral canal: an in vitro analysis of two straight femoral revision stems with a fluted tapered design

Background: The use of tapered fluted revision stems has been shown to be reliable and safe. Primary stability is mandatory for a long-lasting fixation between bone and a prosthesis. Nevertheless, aseptic loosening due to insufficient primary stability occurs and may be related to technically improp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Bischel, Oliver E. (VerfasserIn) , Seeger, Jörn Bengt (VerfasserIn) , Jung, Matthias (VerfasserIn) , Dörfler, Stefan (VerfasserIn) , Höppchen, Arnold (VerfasserIn) , Jahnke, Alexander (VerfasserIn) , Jakubowitz, Eike (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 16 September 2025
In: Bioengineering
Year: 2025, Jahrgang: 12, Heft: 9, Pages: 1-12
ISSN:2306-5354
DOI:10.3390/bioengineering12090984
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.3390/bioengineering12090984
Verlag, kostenfrei, Volltext: https://www.mdpi.com/2306-5354/12/9/984
Volltext
Verfasserangaben:Oliver E. Bischel, Jörn B. Seeger, Matthias K. Jung, Stefan Dörfler, Arnold J. Höppchen, Alexander Jahnke and Eike Jakubowitz

MARC

LEADER 00000caa a2200000 c 4500
001 1940484766
003 DE-627
005 20251110140814.0
007 cr uuu---uuuuu
008 251106s2025 xx |||||o 00| ||eng c
024 7 |a 10.3390/bioengineering12090984  |2 doi 
035 |a (DE-627)1940484766 
035 |a (DE-599)KXP1940484766 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Bischel, Oliver E.  |e VerfasserIn  |0 (DE-588)1161192166  |0 (DE-627)1024607089  |0 (DE-576)185646328  |4 aut 
245 1 4 |a The influence of reaming velocity during preparation of the femoral canal  |b an in vitro analysis of two straight femoral revision stems with a fluted tapered design  |c Oliver E. Bischel, Jörn B. Seeger, Matthias K. Jung, Stefan Dörfler, Arnold J. Höppchen, Alexander Jahnke and Eike Jakubowitz 
264 1 |c 16 September 2025 
300 |b Illustrationen 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 06.11.2025 
520 |a Background: The use of tapered fluted revision stems has been shown to be reliable and safe. Primary stability is mandatory for a long-lasting fixation between bone and a prosthesis. Nevertheless, aseptic loosening due to insufficient primary stability occurs and may be related to technically improper preparation of the femoral canal. Instructions of manufacturers are heterogeneous regarding preparation of implant beds. Questions/Purposes: Does speed or the design of the reamer influence the accuracy of the implant bed and, consecutively, primary stability? Materials and Methods: A test foam with an elastic moduli and pressure resistance similar to that of cancellous bone was used. The medullary canal was prepared with the use of reamers of two different straight and tapered femoral revision devices. Three different rotational speeds were used for preparation. After preparation, primary stability was measured and fixating characteristics were derived. Results: Sufficient primary stability was achievable by all three preparation methods but fixating characteristics were different. Significantly higher micro-motions were detected near the tip of the prosthesis compared to those at all more proximal measuring points. Reaming with high velocity resulted in significantly higher micro-motions compared to that with mid- or low-speed burring. Conclusions: Different preparation methods may be one explanation for the range of reported survivorship data of the two devices with aseptic loosening as the end point. The precision of the implant bed and fixating characteristics were best after reaming with lower velocity. Superior but not significantly better fixation characteristics were achieved with the monobloc stem compared to those with the modular device. 
650 4 |a implant fixation 
650 4 |a modular revision stem 
650 4 |a monobloc revision stem 
650 4 |a revision THA 
700 1 |a Seeger, Jörn Bengt  |d 1980-  |e VerfasserIn  |0 (DE-588)139009272  |0 (DE-627)703179659  |0 (DE-576)309896347  |4 aut 
700 1 |a Jung, Matthias  |e VerfasserIn  |0 (DE-588)1199444359  |0 (DE-627)1681767872  |4 aut 
700 1 |a Dörfler, Stefan  |e VerfasserIn  |4 aut 
700 1 |a Höppchen, Arnold  |d 1978-  |e VerfasserIn  |0 (DE-588)1075748429  |0 (DE-627)833789589  |0 (DE-576)444622861  |4 aut 
700 1 |a Jahnke, Alexander  |e VerfasserIn  |0 (DE-588)1115010182  |0 (DE-627)869461311  |0 (DE-576)477616526  |4 aut 
700 1 |a Jakubowitz, Eike  |d 1973-  |e VerfasserIn  |0 (DE-588)137928424  |0 (DE-627)696194007  |0 (DE-576)305131516  |4 aut 
773 0 8 |i Enthalten in  |t Bioengineering  |d Basel : MDPI, 2014  |g 12(2025), 9, Artikel-ID 984, Seite 1-12  |h Online-Ressource  |w (DE-627)774814020  |w (DE-600)2746191-9  |w (DE-576)399193375  |x 2306-5354  |7 nnas  |a The influence of reaming velocity during preparation of the femoral canal an in vitro analysis of two straight femoral revision stems with a fluted tapered design 
773 1 8 |g volume:12  |g year:2025  |g number:9  |g elocationid:984  |g pages:1-12  |g extent:12  |a The influence of reaming velocity during preparation of the femoral canal an in vitro analysis of two straight femoral revision stems with a fluted tapered design 
856 4 0 |u https://doi.org/10.3390/bioengineering12090984  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.mdpi.com/2306-5354/12/9/984  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20251106 
993 |a Article 
994 |a 2025 
998 |g 1075748429  |a Höppchen, Arnold  |m 1075748429:Höppchen, Arnold  |d 60000  |d 62400  |e 60000PH1075748429  |e 62400PH1075748429  |k 0/60000/  |k 1/60000/62400/  |p 5 
998 |g 1199444359  |a Jung, Matthias  |m 1199444359:Jung, Matthias  |d 50000  |e 50000PJ1199444359  |k 0/50000/  |p 3 
998 |g 1161192166  |a Bischel, Oliver E.  |m 1161192166:Bischel, Oliver E.  |d 910000  |d 910200  |d 50000  |e 910000PB1161192166  |e 910200PB1161192166  |e 50000PB1161192166  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 1  |x j 
999 |a KXP-PPN1940484766  |e 4797573295 
BIB |a Y 
SER |a journal 
JSO |a {"title":[{"title":"The influence of reaming velocity during preparation of the femoral canal","subtitle":"an in vitro analysis of two straight femoral revision stems with a fluted tapered design","title_sort":"influence of reaming velocity during preparation of the femoral canal"}],"person":[{"roleDisplay":"VerfasserIn","display":"Bischel, Oliver E.","role":"aut","family":"Bischel","given":"Oliver E."},{"given":"Jörn Bengt","family":"Seeger","role":"aut","roleDisplay":"VerfasserIn","display":"Seeger, Jörn Bengt"},{"family":"Jung","given":"Matthias","display":"Jung, Matthias","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Dörfler","given":"Stefan","roleDisplay":"VerfasserIn","display":"Dörfler, Stefan","role":"aut"},{"display":"Höppchen, Arnold","roleDisplay":"VerfasserIn","role":"aut","family":"Höppchen","given":"Arnold"},{"roleDisplay":"VerfasserIn","display":"Jahnke, Alexander","role":"aut","family":"Jahnke","given":"Alexander"},{"given":"Eike","family":"Jakubowitz","role":"aut","roleDisplay":"VerfasserIn","display":"Jakubowitz, Eike"}],"recId":"1940484766","language":["eng"],"note":["Gesehen am 06.11.2025"],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"eki":["1940484766"],"doi":["10.3390/bioengineering12090984"]},"origin":[{"dateIssuedDisp":"16 September 2025","dateIssuedKey":"2025"}],"name":{"displayForm":["Oliver E. Bischel, Jörn B. Seeger, Matthias K. Jung, Stefan Dörfler, Arnold J. Höppchen, Alexander Jahnke and Eike Jakubowitz"]},"relHost":[{"pubHistory":["1.2014 -"],"part":{"pages":"1-12","issue":"9","year":"2025","extent":"12","volume":"12","text":"12(2025), 9, Artikel-ID 984, Seite 1-12"},"disp":"The influence of reaming velocity during preparation of the femoral canal an in vitro analysis of two straight femoral revision stems with a fluted tapered designBioengineering","type":{"media":"Online-Ressource","bibl":"periodical"},"note":["Gesehen am 20.05.2020"],"language":["eng"],"recId":"774814020","title":[{"subtitle":"open access journal","title":"Bioengineering","title_sort":"Bioengineering"}],"physDesc":[{"extent":"Online-Ressource"}],"origin":[{"dateIssuedKey":"2014","publisher":"MDPI","dateIssuedDisp":"2014-","publisherPlace":"Basel"}],"id":{"issn":["2306-5354"],"eki":["774814020"],"zdb":["2746191-9"]}}],"physDesc":[{"extent":"12 S.","noteIll":"Illustrationen"}]} 
SRT |a BISCHELOLIINFLUENCEO1620