Spectral attenuation curves of photon-counting detector CT scans for the differentiation between mucinous and non-mucinous cyst fluids of pancreatic lesions: a proof-of-concept study

Abstract - - Background - Spectral imaging via photon-counting detector CT (PCD-CT) scanners allows the generation of spectral attenuation curves. Our study aimed to test the feasibility of spectral attenuation curve analysis for differentiating mucinous from...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Dudás, Ibolyka (VerfasserIn) , Lovász, Borbála (VerfasserIn) , Benke, Márton (VerfasserIn) , Kiss, Máté (VerfasserIn) , Juergens, Markus (VerfasserIn) , Szücs, Ákos (VerfasserIn) , Kaposi, Pál N. (VerfasserIn) , Szijártó, Attila (VerfasserIn) , Maurovich-Horvat, Pál (VerfasserIn) , Budai, Bettina Katalin (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 01 July 2025
In: BMC medical imaging
Year: 2025, Jahrgang: 25, Pages: 1-12
ISSN:1471-2342
DOI:10.1186/s12880-025-01770-6
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1186/s12880-025-01770-6
Verlag, kostenfrei, Volltext: https://bmcmedimaging.biomedcentral.com/articles/10.1186/s12880-025-01770-6
Volltext
Verfasserangaben:Ibolyka Dudás, Borbála Lovász, Márton Benke, Máté Kiss, Markus Juergens, Ákos Szücs, Pál N. Kaposi, Attila Szijártó, Pál Maurovich-Horvat and Bettina K. Budai

MARC

LEADER 00000caa a2200000 c 4500
001 1942961707
003 DE-627
005 20251215111346.0
007 cr uuu---uuuuu
008 251201s2025 xx |||||o 00| ||eng c
024 7 |a 10.1186/s12880-025-01770-6  |2 doi 
035 |a (DE-627)1942961707 
035 |a (DE-599)KXP1942961707 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Dudás, Ibolyka  |e VerfasserIn  |0 (DE-588)1356054145  |0 (DE-627)191709874X  |4 aut 
245 1 0 |a Spectral attenuation curves of photon-counting detector CT scans for the differentiation between mucinous and non-mucinous cyst fluids of pancreatic lesions  |b a proof-of-concept study  |c Ibolyka Dudás, Borbála Lovász, Márton Benke, Máté Kiss, Markus Juergens, Ákos Szücs, Pál N. Kaposi, Attila Szijártó, Pál Maurovich-Horvat and Bettina K. Budai 
264 1 |c 01 July 2025 
300 |a 12 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 01.12.2025 
520 |a Abstract - - Background - Spectral imaging via photon-counting detector CT (PCD-CT) scanners allows the generation of spectral attenuation curves. Our study aimed to test the feasibility of spectral attenuation curve analysis for differentiating mucinous from non-mucinous cyst fluids of pancreatic cystic lesions (PCL). - - - Methods - - Our study included 74 patients with PCLs. The classic morphological features were evaluated by an expert radiologist. The spectral attenuation curves were generated from the pancreatic-phase scans. The average CT values were measured on the 70 keV (HU - 70keV - ) and 40 keV (HU - 40keV - ) virtual monoenergetic images (VMIs), and the differences were calculated (HU - Δ40−70keV - ). The cases were divided into training (53 mucinous vs. 19 non-mucinous PCLs) and test (10 mucinous vs. 10 non-mucinous PCLs) datasets. The receiver operating characteristic (ROC) curve analysis assessed the discrimination performance. The intra- and interobserver reproducibilities were evaluated by the intraclass correlation coefficient (ICC). - - - - Results - - On 70 keV VMIs, no significant differences were found between the average CT values of mucinous and non-mucinous PCLs, however, the difference was significant in HU - Δ40−70keV - values ( - p -  < 0.0001). The diagnostic performance of HU - Δ40−70keV - in differentiating between mucinous vs. non-mucinous PCL had AUCs of 0.92 and 0.92 on the training and test datasets, respectively, with a good interobserver (ICC = 0.82) and excellent intraobserver reproducibility (ICC = 0.94). The conventional clinical-radiological model achieved AUCs of 0.85 and 0.86, and with the addition of HU - Δ40−70keV - values its performance increased significantly to 0.98 and 0.94 on the training and test datasets, respectively. - - - - Conclusions - Spectral attenuation curve assessment of cyst fluids could be a useful additional measurement to facilitate the noninvasive differential diagnosis of PCLs. 
700 1 |a Lovász, Borbála  |e VerfasserIn  |4 aut 
700 1 |a Benke, Márton  |e VerfasserIn  |4 aut 
700 1 |a Kiss, Máté  |e VerfasserIn  |4 aut 
700 1 |a Juergens, Markus  |e VerfasserIn  |4 aut 
700 1 |a Szücs, Ákos  |e VerfasserIn  |4 aut 
700 1 |a Kaposi, Pál N.  |e VerfasserIn  |4 aut 
700 1 |a Szijártó, Attila  |e VerfasserIn  |4 aut 
700 1 |a Maurovich-Horvat, Pál  |e VerfasserIn  |4 aut 
700 1 |a Budai, Bettina Katalin  |e VerfasserIn  |0 (DE-588)1356059929  |0 (DE-627)1917100949  |4 aut 
773 0 8 |i Enthalten in  |t BMC medical imaging  |d London : BioMed Central, 2001  |g 25(2025), Artikel-ID 239, Seite 1-12  |h Online-Ressource  |w (DE-627)33679911X  |w (DE-600)2061975-3  |w (DE-576)107015137  |x 1471-2342  |7 nnas  |a Spectral attenuation curves of photon-counting detector CT scans for the differentiation between mucinous and non-mucinous cyst fluids of pancreatic lesions a proof-of-concept study 
773 1 8 |g volume:25  |g year:2025  |g elocationid:239  |g pages:1-12  |g extent:12  |a Spectral attenuation curves of photon-counting detector CT scans for the differentiation between mucinous and non-mucinous cyst fluids of pancreatic lesions a proof-of-concept study 
856 4 0 |u https://doi.org/10.1186/s12880-025-01770-6  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext  |7 0 
856 4 0 |u https://bmcmedimaging.biomedcentral.com/articles/10.1186/s12880-025-01770-6  |x Verlag  |z kostenfrei  |3 Volltext  |7 0 
951 |a AR 
992 |a 20251201 
993 |a Article 
994 |a 2025 
998 |g 1356059929  |a Budai, Bettina Katalin  |m 1356059929:Budai, Bettina Katalin  |d 910000  |d 911400  |e 910000PB1356059929  |e 911400PB1356059929  |k 0/910000/  |k 1/910000/911400/  |p 10  |y j 
999 |a KXP-PPN1942961707  |e 4818128171 
BIB |a Y 
SER |a journal 
JSO |a {"note":["Gesehen am 01.12.2025"],"id":{"eki":["1942961707"],"doi":["10.1186/s12880-025-01770-6"]},"relHost":[{"pubHistory":["1.2001 -"],"title":[{"title":"BMC medical imaging","title_sort":"BMC medical imaging"}],"origin":[{"publisher":"BioMed Central","dateIssuedDisp":"2001-","dateIssuedKey":"2001","publisherPlace":"London"}],"language":["eng"],"part":{"extent":"12","volume":"25","year":"2025","text":"25(2025), Artikel-ID 239, Seite 1-12","pages":"1-12"},"physDesc":[{"extent":"Online-Ressource"}],"disp":"Spectral attenuation curves of photon-counting detector CT scans for the differentiation between mucinous and non-mucinous cyst fluids of pancreatic lesions a proof-of-concept studyBMC medical imaging","type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"33679911X","note":["Gesehen am 01.02.16"],"id":{"zdb":["2061975-3"],"eki":["33679911X"],"issn":["1471-2342"]}}],"name":{"displayForm":["Ibolyka Dudás, Borbála Lovász, Márton Benke, Máté Kiss, Markus Juergens, Ákos Szücs, Pál N. Kaposi, Attila Szijártó, Pál Maurovich-Horvat and Bettina K. Budai"]},"language":["eng"],"recId":"1942961707","type":{"bibl":"article-journal","media":"Online-Ressource"},"origin":[{"dateIssuedDisp":"01 July 2025","dateIssuedKey":"2025"}],"person":[{"roleDisplay":"VerfasserIn","given":"Ibolyka","role":"aut","display":"Dudás, Ibolyka","family":"Dudás"},{"family":"Lovász","display":"Lovász, Borbála","roleDisplay":"VerfasserIn","given":"Borbála","role":"aut"},{"display":"Benke, Márton","family":"Benke","given":"Márton","roleDisplay":"VerfasserIn","role":"aut"},{"family":"Kiss","display":"Kiss, Máté","role":"aut","roleDisplay":"VerfasserIn","given":"Máté"},{"family":"Juergens","display":"Juergens, Markus","role":"aut","roleDisplay":"VerfasserIn","given":"Markus"},{"display":"Szücs, Ákos","family":"Szücs","role":"aut","roleDisplay":"VerfasserIn","given":"Ákos"},{"given":"Pál N.","roleDisplay":"VerfasserIn","role":"aut","display":"Kaposi, Pál N.","family":"Kaposi"},{"roleDisplay":"VerfasserIn","given":"Attila","role":"aut","family":"Szijártó","display":"Szijártó, Attila"},{"roleDisplay":"VerfasserIn","given":"Pál","role":"aut","display":"Maurovich-Horvat, Pál","family":"Maurovich-Horvat"},{"role":"aut","roleDisplay":"VerfasserIn","given":"Bettina Katalin","display":"Budai, Bettina Katalin","family":"Budai"}],"physDesc":[{"extent":"12 S."}],"title":[{"title_sort":"Spectral attenuation curves of photon-counting detector CT scans for the differentiation between mucinous and non-mucinous cyst fluids of pancreatic lesions","title":"Spectral attenuation curves of photon-counting detector CT scans for the differentiation between mucinous and non-mucinous cyst fluids of pancreatic lesions","subtitle":"a proof-of-concept study"}]} 
SRT |a DUDASIBOLYSPECTRALAT0120