Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements

A model based noise correction algorithm was developed to improve the accuracy of CT perfusion (CTp) blood flow (BF) measurements affected by image noise. The algorithm used tissue attenuation curves (TACs), generated by convolving an impulse response function (IRF) with an arterial input function (...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Vats, Neha (VerfasserIn) , Mayer, Philipp (VerfasserIn) , Kortes, Franziska (VerfasserIn) , Klauß, Miriam (VerfasserIn) , Grenacher, Lars (VerfasserIn) , Kauczor, Hans-Ulrich (VerfasserIn) , Stiller, Wolfram (VerfasserIn) , Skornitzke, Stephan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 23 October 2025
In: Scientific reports
Year: 2025, Jahrgang: 15, Pages: 1-13
ISSN:2045-2322
DOI:10.1038/s41598-025-24482-x
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1038/s41598-025-24482-x
Verlag, kostenfrei, Volltext: https://www.nature.com/articles/s41598-025-24482-x
Volltext
Verfasserangaben:Neha Vats, Philipp Mayer, Franziska Kortes, Miriam Klauß, Lars Grenacher, Hans-Ulrich Kauczor, Wolfram Stiller & Stephan Skornitzke

MARC

LEADER 00000naa a2200000 c 4500
001 1944396985
003 DE-627
005 20251204090900.0
007 cr uuu---uuuuu
008 251204s2025 xx |||||o 00| ||eng c
024 7 |a 10.1038/s41598-025-24482-x  |2 doi 
035 |a (DE-627)1944396985 
035 |a (DE-599)KXP1944396985 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Vats, Neha  |d 1993-  |e VerfasserIn  |0 (DE-588)1283965690  |0 (DE-627)1839656263  |4 aut 
245 1 0 |a Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements  |c Neha Vats, Philipp Mayer, Franziska Kortes, Miriam Klauß, Lars Grenacher, Hans-Ulrich Kauczor, Wolfram Stiller & Stephan Skornitzke 
264 1 |c 23 October 2025 
300 |b Illustrationen 
300 |a 13 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 23. Oktober 2025 
500 |a Gesehen am 04.12.2025 
520 |a A model based noise correction algorithm was developed to improve the accuracy of CT perfusion (CTp) blood flow (BF) measurements affected by image noise. The algorithm used tissue attenuation curves (TACs), generated by convolving an impulse response function (IRF) with an arterial input function (AIF) averaged from 59 patient datasets. Gaussian noise was introduced to simulate noise, and BF was measured using deconvolution. The algorithm iteratively compared BF without added noise against noise-impacted BF to estimate ground-truth BF (GTBF). Performance was evaluated with digital perfusion phantoms (DPPs) for GTBF values of 5-420 ml/100 ml/min and added noise (standard deviation 25 HU), measuring absolute difference from GTBF and contrast-to-noise ratio (CNR). For clinical evaluation, CTp data from 14 pancreatic ductal adenocarcinoma (PDAC) patients was used. For DPPs, noise-impacted and noise-corrected BF were 140 ± 111 ml/100 ml/min and 131 ± 125 ml/100 ml/min, compared to GTBF of 131 ± 127 ml/100 ml/min. Post-correction, the absolute difference reduced from 18.8 to 3.6 ml/100 ml/min, with CNR improving from 2.52 to 2.66. In clinical datasets, BF for parenchyma shifted from 148 ± 50.8 to 84.1 ± 96.9 ml/100 ml/min, and for PDAC, from 45.8 ± 20.3 to 13.3 ± 18.7 ml/100 ml/min. The algorithm reduced noise impact, improving BF accuracy and CNR, with potential for lower-dose CT without compromising diagnostic quality. 
650 4 |a Computed tomography 
650 4 |a Pancreatic cancer 
700 1 |a Mayer, Philipp  |d 1985-  |e VerfasserIn  |0 (DE-588)1066605440  |0 (DE-627)817714758  |0 (DE-576)426052250  |4 aut 
700 1 |a Kortes, Franziska  |e VerfasserIn  |4 aut 
700 1 |a Klauß, Miriam  |d 1978-  |e VerfasserIn  |0 (DE-588)130870552  |0 (DE-627)506783839  |0 (DE-576)29838728X  |4 aut 
700 1 |a Grenacher, Lars  |d 1967-  |e VerfasserIn  |0 (DE-588)115424598  |0 (DE-627)691308977  |0 (DE-576)289876761  |4 aut 
700 1 |a Kauczor, Hans-Ulrich  |d 1962-  |e VerfasserIn  |0 (DE-588)139267123  |0 (DE-627)70327113X  |0 (DE-576)310955327  |4 aut 
700 1 |a Stiller, Wolfram  |d 1976-  |e VerfasserIn  |0 (DE-588)105822672X  |0 (DE-627)796627495  |0 (DE-576)414249496  |4 aut 
700 1 |a Skornitzke, Stephan  |d 1987-  |e VerfasserIn  |0 (DE-588)1110072589  |0 (DE-627)864783523  |0 (DE-576)475718267  |4 aut 
773 0 8 |i Enthalten in  |t Scientific reports  |d [London] : Springer Nature, 2011  |g 15(2025), Artikel-ID 37165, Seite 1-13  |h Online-Ressource  |w (DE-627)663366712  |w (DE-600)2615211-3  |w (DE-576)346641179  |x 2045-2322  |7 nnas  |a Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements 
773 1 8 |g volume:15  |g year:2025  |g elocationid:37165  |g pages:1-13  |g extent:13  |a Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements 
856 4 0 |u https://doi.org/10.1038/s41598-025-24482-x  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.nature.com/articles/s41598-025-24482-x  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20251204 
993 |a Article 
994 |a 2025 
998 |g 1110072589  |a Skornitzke, Stephan  |m 1110072589:Skornitzke, Stephan  |d 50000  |e 50000PS1110072589  |k 0/50000/  |p 8  |y j 
998 |g 105822672X  |a Stiller, Wolfram  |m 105822672X:Stiller, Wolfram  |d 910000  |d 911400  |d 50000  |e 910000PS105822672X  |e 911400PS105822672X  |e 50000PS105822672X  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 7 
998 |g 139267123  |a Kauczor, Hans-Ulrich  |m 139267123:Kauczor, Hans-Ulrich  |d 910000  |d 911400  |e 910000PK139267123  |e 911400PK139267123  |k 0/910000/  |k 1/910000/911400/  |p 6 
998 |g 115424598  |a Grenacher, Lars  |m 115424598:Grenacher, Lars  |d 50000  |e 50000PG115424598  |k 0/50000/  |p 5 
998 |g 130870552  |a Klauß, Miriam  |m 130870552:Klauß, Miriam  |d 910000  |d 911400  |d 50000  |e 910000PK130870552  |e 911400PK130870552  |e 50000PK130870552  |k 0/910000/  |k 1/910000/911400/  |k 0/50000/  |p 4 
998 |g 1066605440  |a Mayer, Philipp  |m 1066605440:Mayer, Philipp  |d 910000  |d 911400  |e 910000PM1066605440  |e 911400PM1066605440  |k 0/910000/  |k 1/910000/911400/  |p 2 
998 |g 1283965690  |a Vats, Neha  |m 1283965690:Vats, Neha  |p 1  |x j 
999 |a KXP-PPN1944396985  |e 4821368420 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"disp":"Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurementsScientific reports","recId":"663366712","physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["2615211-3"],"eki":["663366712"],"issn":["2045-2322"]},"part":{"extent":"13","volume":"15","text":"15(2025), Artikel-ID 37165, Seite 1-13","year":"2025","pages":"1-13"},"title":[{"title_sort":"Scientific reports","title":"Scientific reports"}],"language":["eng"],"type":{"bibl":"periodical","media":"Online-Ressource"},"note":["Gesehen am 12.07.24"],"origin":[{"publisherPlace":"[London] ; London","dateIssuedKey":"2011","dateIssuedDisp":"2011-","publisher":"Springer Nature ; Nature Publishing Group"}],"pubHistory":["1, article number 1 (2011)-"]}],"person":[{"display":"Vats, Neha","family":"Vats","role":"aut","given":"Neha"},{"role":"aut","given":"Philipp","family":"Mayer","display":"Mayer, Philipp"},{"given":"Franziska","role":"aut","family":"Kortes","display":"Kortes, Franziska"},{"display":"Klauß, Miriam","family":"Klauß","given":"Miriam","role":"aut"},{"display":"Grenacher, Lars","given":"Lars","role":"aut","family":"Grenacher"},{"display":"Kauczor, Hans-Ulrich","family":"Kauczor","role":"aut","given":"Hans-Ulrich"},{"family":"Stiller","role":"aut","given":"Wolfram","display":"Stiller, Wolfram"},{"family":"Skornitzke","role":"aut","given":"Stephan","display":"Skornitzke, Stephan"}],"origin":[{"dateIssuedDisp":"23 October 2025","dateIssuedKey":"2025"}],"note":["Veröffentlicht: 23. Oktober 2025","Gesehen am 04.12.2025"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"language":["eng"],"title":[{"title":"Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements","title_sort":"Model based noise correction enhances the accuracy of pancreatic CT perfusion blood flow measurements"}],"physDesc":[{"extent":"13 S.","noteIll":"Illustrationen"}],"recId":"1944396985","name":{"displayForm":["Neha Vats, Philipp Mayer, Franziska Kortes, Miriam Klauß, Lars Grenacher, Hans-Ulrich Kauczor, Wolfram Stiller & Stephan Skornitzke"]},"id":{"eki":["1944396985"],"doi":["10.1038/s41598-025-24482-x"]}} 
SRT |a VATSNEHAMAMODELBASED2320