Unintentional false lumen placement of frozen elephant trunk in aortic dissections: root cause analysis of morphological risk factors

To analyse morphological features associated with unintentional frozen elephant trunk (FET) placement in the false lumen (FL) during aortic dissection (AD) repair.This multicentre retrospective study enrolled patients with acute/chronic AD with unintentional FET placement in the FL. To identify morp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Körfer, Daniel (VerfasserIn) , Wong, Brian (VerfasserIn) , Fujii, Masahiko (VerfasserIn) , Hori, Daijiro (VerfasserIn) , Takagi, Daichi (VerfasserIn) , Wortmann, Markus (VerfasserIn) , Geisbüsch, Philipp (VerfasserIn) , Manesh, Michelle (VerfasserIn) , Magee, Gregory A (VerfasserIn) , Karck, Matthias (VerfasserIn) , Meisenbacher, Katrin (VerfasserIn) , Böckler, Dittmar (VerfasserIn) , Peters, Andreas (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 2025
In: European journal of cardio-thoracic surgery
Year: 2025, Jahrgang: 67, Heft: 10, Pages: 1-8
ISSN:1873-734X
DOI:10.1093/ejcts/ezaf349
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1093/ejcts/ezaf349
Volltext
Verfasserangaben:Daniel Körfer, Brian Wong, Masahiko Fujii, Daijiro Hori, Daichi Takagi, Markus Wortmann, Philipp Geisbüsch, Michelle Manesh, Gregory A Magee, Matthias Karck, Katrin Meisenbacher, Dittmar Böckler, Andreas S. Peters

MARC

LEADER 00000naa a2200000 c 4500
001 1944946012
003 DE-627
005 20251205122348.0
007 cr uuu---uuuuu
008 251205s2025 xx |||||o 00| ||eng c
024 7 |a 10.1093/ejcts/ezaf349  |2 doi 
035 |a (DE-627)1944946012 
035 |a (DE-599)KXP1944946012 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Körfer, Daniel  |d 1988-  |e VerfasserIn  |0 (DE-588)1223562735  |0 (DE-627)1743025858  |4 aut 
245 1 0 |a Unintentional false lumen placement of frozen elephant trunk in aortic dissections  |b root cause analysis of morphological risk factors  |c Daniel Körfer, Brian Wong, Masahiko Fujii, Daijiro Hori, Daichi Takagi, Markus Wortmann, Philipp Geisbüsch, Michelle Manesh, Gregory A Magee, Matthias Karck, Katrin Meisenbacher, Dittmar Böckler, Andreas S. Peters 
264 1 |c October 2025 
300 |b Illustrationen 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 11. Oktober 2025 
500 |a Gesehen am 05.12.2025 
520 |a To analyse morphological features associated with unintentional frozen elephant trunk (FET) placement in the false lumen (FL) during aortic dissection (AD) repair.This multicentre retrospective study enrolled patients with acute/chronic AD with unintentional FET placement in the FL. To identify morphological features, pre-/postoperative CT, clinical and procedural data were assessed. Imaging analysis focused on size and position of the relevant (re-)entry (rE) in the distal aortic arch and postoperative FET-position.Thirteen male patients (54 years, interquartile range [IQR]: 18 years) from 6 international centres were included between 2017 and 2023. Aortic pathologies comprised 5 acute Type-A-AD (38.5%), 4 acute Type-B-AD (30.8%), 1 chronic Type-B-AD (7.7%), and 3 chronic expanding residual Type-A-AD (23.1%). The rE (first [re-]entry distal to left subclavian artery [LSA] origin) had a median diameter of 15.5 mm (IQR: 9.4 mm) and was mostly located in zone 3 (61.5%), the outer curvature (61.5%), and 21.1 mm (IQR: 26.4 mm) distal to the LSA. The stented portion of the FET (FETSP) lengths measured 60-190 mm. FETSP proximal end was mostly located in zone 1 (38.5%) and at median distance of 28.2 mm (IQR: 26.5 mm) from the native LSA. FETSP distal end was mostly located in zone 5 (61.5%). Median calculated distance from rE to FETSP proximal end was 38.9 mm (IQR: 39.0 mm). Three patients (23.1%) died perioperatively; the others remained asymptomatic (follow-up: 13 mo [IQR: 15 mo]).Large (re-)entries in the outer curvature of the distal aortic arch are common in patients with FET placement in the FL. Interdisciplinary collaboration with controlled, wire-guided FET placement and usage of advanced intraoperative imaging (cone-beam-CT, transesophageal echocardiography, intravascular ultrasound, angioscopy) may help minimize risk of FL deployment. 
700 1 |a Wong, Brian  |e VerfasserIn  |4 aut 
700 1 |a Fujii, Masahiko  |e VerfasserIn  |4 aut 
700 1 |a Hori, Daijiro  |e VerfasserIn  |4 aut 
700 1 |a Takagi, Daichi  |e VerfasserIn  |4 aut 
700 1 |a Wortmann, Markus  |e VerfasserIn  |4 aut 
700 1 |a Geisbüsch, Philipp  |e VerfasserIn  |4 aut 
700 1 |a Manesh, Michelle  |e VerfasserIn  |4 aut 
700 1 |a Magee, Gregory A  |e VerfasserIn  |4 aut 
700 1 |a Karck, Matthias  |d 1961-  |e VerfasserIn  |0 (DE-588)130833525  |0 (DE-627)505909340  |0 (DE-576)298366169  |4 aut 
700 1 |a Meisenbacher, Katrin  |d 1985-  |e VerfasserIn  |0 (DE-588)1106281799  |0 (DE-627)862985838  |0 (DE-576)473983206  |4 aut 
700 1 |a Böckler, Dittmar  |d 1966-  |e VerfasserIn  |0 (DE-588)1032367881  |0 (DE-627)738382868  |0 (DE-576)173503969  |4 aut 
700 1 |a Peters, Andreas  |d 1982-  |e VerfasserIn  |0 (DE-588)143674587  |0 (DE-627)704565943  |0 (DE-576)338312617  |4 aut 
773 0 8 |i Enthalten in  |t European journal of cardio-thoracic surgery  |d Oxford : Oxford Univ. Press, 1987  |g 67(2025), 10 vom: Okt., Artikel-ID ezaf349, Seite 1-8  |h Online-Ressource  |w (DE-627)306658275  |w (DE-600)1500330-9  |w (DE-576)081985975  |x 1873-734X  |7 nnas  |a Unintentional false lumen placement of frozen elephant trunk in aortic dissections root cause analysis of morphological risk factors 
773 1 8 |g volume:67  |g year:2025  |g number:10  |g month:10  |g elocationid:ezaf349  |g pages:1-8  |g extent:8  |a Unintentional false lumen placement of frozen elephant trunk in aortic dissections root cause analysis of morphological risk factors 
856 4 0 |u https://doi.org/10.1093/ejcts/ezaf349  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20251205 
993 |a Article 
994 |a 2025 
998 |g 143674587  |a Peters, Andreas  |m 143674587:Peters, Andreas  |d 910000  |d 910200  |d 50000  |e 910000PP143674587  |e 910200PP143674587  |e 50000PP143674587  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 13  |y j 
998 |g 1032367881  |a Böckler, Dittmar  |m 1032367881:Böckler, Dittmar  |d 910000  |d 910200  |e 910000PB1032367881  |e 910200PB1032367881  |k 0/910000/  |k 1/910000/910200/  |p 12 
998 |g 1106281799  |a Meisenbacher, Katrin  |m 1106281799:Meisenbacher, Katrin  |d 910000  |d 910200  |d 50000  |e 910000PM1106281799  |e 910200PM1106281799  |e 50000PM1106281799  |k 0/910000/  |k 1/910000/910200/  |k 0/50000/  |p 11 
998 |g 130833525  |a Karck, Matthias  |m 130833525:Karck, Matthias  |d 910000  |d 910200  |e 910000PK130833525  |e 910200PK130833525  |k 0/910000/  |k 1/910000/910200/  |p 10 
998 |g 1223562735  |a Körfer, Daniel  |m 1223562735:Körfer, Daniel  |d 910000  |d 910200  |e 910000PK1223562735  |e 910200PK1223562735  |k 0/910000/  |k 1/910000/910200/  |p 1  |x j 
999 |a KXP-PPN1944946012  |e 4823349873 
BIB |a Y 
SER |a journal 
JSO |a {"language":["eng"],"name":{"displayForm":["Daniel Körfer, Brian Wong, Masahiko Fujii, Daijiro Hori, Daichi Takagi, Markus Wortmann, Philipp Geisbüsch, Michelle Manesh, Gregory A Magee, Matthias Karck, Katrin Meisenbacher, Dittmar Böckler, Andreas S. Peters"]},"person":[{"family":"Körfer","role":"aut","given":"Daniel","display":"Körfer, Daniel"},{"role":"aut","family":"Wong","display":"Wong, Brian","given":"Brian"},{"role":"aut","family":"Fujii","display":"Fujii, Masahiko","given":"Masahiko"},{"display":"Hori, Daijiro","given":"Daijiro","family":"Hori","role":"aut"},{"display":"Takagi, Daichi","given":"Daichi","role":"aut","family":"Takagi"},{"given":"Markus","display":"Wortmann, Markus","role":"aut","family":"Wortmann"},{"role":"aut","family":"Geisbüsch","display":"Geisbüsch, Philipp","given":"Philipp"},{"family":"Manesh","role":"aut","given":"Michelle","display":"Manesh, Michelle"},{"role":"aut","family":"Magee","display":"Magee, Gregory A","given":"Gregory A"},{"display":"Karck, Matthias","given":"Matthias","role":"aut","family":"Karck"},{"display":"Meisenbacher, Katrin","given":"Katrin","role":"aut","family":"Meisenbacher"},{"given":"Dittmar","display":"Böckler, Dittmar","role":"aut","family":"Böckler"},{"role":"aut","family":"Peters","display":"Peters, Andreas","given":"Andreas"}],"recId":"1944946012","note":["Veröffentlicht: 11. Oktober 2025","Gesehen am 05.12.2025"],"title":[{"title_sort":"Unintentional false lumen placement of frozen elephant trunk in aortic dissections","title":"Unintentional false lumen placement of frozen elephant trunk in aortic dissections","subtitle":"root cause analysis of morphological risk factors"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"physDesc":[{"extent":"8 S.","noteIll":"Illustrationen"}],"id":{"doi":["10.1093/ejcts/ezaf349"],"eki":["1944946012"]},"relHost":[{"title":[{"title":"European journal of cardio-thoracic surgery","subtitle":"official journal of the European Association for Cardio-Thoracic Surgery and the European Society of Thoracic Surgeons","title_sort":"European journal of cardio-thoracic surgery"}],"physDesc":[{"extent":"Online-Ressource"}],"id":{"eki":["306658275"],"issn":["1873-734X"],"zdb":["1500330-9"]},"origin":[{"publisherPlace":"Oxford ; Amsterdam [u.a.]","dateIssuedKey":"1987","dateIssuedDisp":"1987-","publisher":"Oxford Univ. Press ; Elsevier Science"}],"recId":"306658275","disp":"Unintentional false lumen placement of frozen elephant trunk in aortic dissections root cause analysis of morphological risk factorsEuropean journal of cardio-thoracic surgery","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Cardio-thoracic surgery"}],"language":["eng"],"part":{"volume":"67","year":"2025","text":"67(2025), 10 vom: Okt., Artikel-ID ezaf349, Seite 1-8","issue":"10","pages":"1-8","extent":"8"},"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 15.01.2021"],"pubHistory":["1.1987 -"]}],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"October 2025"}]} 
SRT |a KOERFERDANUNINTENTIO2025