Lung cancer screening CT acquisition protocols for three generations of CT systems conforming to German legislation
Objective - Develop a computed tomography (CT) acquisition protocol for lung cancer screening compliant with German legislation across three CT system generations, addressing standardization of image quality and radiation dose amid technical variability. - Materials and methods - Three CT systems, a...
Gespeichert in:
| Hauptverfasser: | , , , , , , , , |
|---|---|
| Dokumenttyp: | Article (Journal) |
| Sprache: | Englisch |
| Veröffentlicht: |
November 2025
|
| In: |
Physica medica
Year: 2025, Jahrgang: 139, Pages: 1-10 |
| ISSN: | 1724-191X |
| DOI: | 10.1016/j.ejmp.2025.105208 |
| Online-Zugang: | Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.ejmp.2025.105208 Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S1120179725003187 |
| Verfasserangaben: | Stefan Sawall, Joscha Maier, Christian H. Ziener, Heinz-Peter Schlemmer, Thuy D. Do, Hans-Ulrich Kauczor, Stefan O. Schoenberg, Matthias F. Froelich, Marc Kachelrieß |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1945089741 | ||
| 003 | DE-627 | ||
| 005 | 20251210125933.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 251209s2025 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.ejmp.2025.105208 |2 doi | |
| 035 | |a (DE-627)1945089741 | ||
| 035 | |a (DE-599)KXP1945089741 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Sawall, Stefan |d 1985- |e VerfasserIn |0 (DE-588)1031331298 |0 (DE-627)736275746 |0 (DE-576)378788841 |4 aut | |
| 245 | 1 | 0 | |a Lung cancer screening CT acquisition protocols for three generations of CT systems conforming to German legislation |c Stefan Sawall, Joscha Maier, Christian H. Ziener, Heinz-Peter Schlemmer, Thuy D. Do, Hans-Ulrich Kauczor, Stefan O. Schoenberg, Matthias F. Froelich, Marc Kachelrieß |
| 264 | 1 | |c November 2025 | |
| 300 | |b Illustrationen, Diagramme | ||
| 300 | |a 10 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Online verfügbar: 24. Oktober 2025, Artikelversion: 24. Oktober 2025 | ||
| 500 | |a Gesehen am 09.12.2025 | ||
| 520 | |a Objective - Develop a computed tomography (CT) acquisition protocol for lung cancer screening compliant with German legislation across three CT system generations, addressing standardization of image quality and radiation dose amid technical variability. - Materials and methods - Three CT systems, a first-generation dual-source energy-integrating (EID) CT (Somatom Flash), a second-generation dual-source EID CT (Somatom Force), and a photon-counting CT (Naeotom Alpha), were evaluated. An anthropomorphic thorax phantom with fat rings was used to simulate small, medium, and large patients and included lesions with 150 HU contrast. Image quality was quantified via contrast-to-noise ratio (CNR) at multiple dose levels. Focus was placed on the system-specific adaptation of acquisition and reconstruction parameters, reflecting the challenges faced in harmonizing imaging protocols across diverse hardware generations. - Results - At matched CTDI, CNR varied markedly, with newer systems performing best. Thicker slices improved CNR. To reach the defined target of a CNR of 2.2 on 3.0 mm slices, the required CTDI were, in the small phantom, Flash and Force about 0.37 mGy and Alpha 0.26-0.19 mGy. In the medium phantom, Flash 1.30 mGy, Force about 0.96 mGy, and Alpha 0.46-0.24 mGy. In the large phantom, Flash 3.34 mGy, Force 5.15 mGy, and Alpha 2.08-0.69 mGy. Required dose increased with phantom size and differed by system generation, underscoring the clinical difficulty of “one-size-fits-all” dose specifications. - Conclusions - Uniform protocol implementation across CT platforms is challenged by hardware and reconstruction disparities. Patient-size-adapted and system-specific protocols are essential to balance diagnostic performance and radiation safety for future lung cancer screening programs. | ||
| 650 | 4 | |a Computed tomography | |
| 650 | 4 | |a Image quality | |
| 650 | 4 | |a Lung cancer screening | |
| 650 | 4 | |a Scan protocol design | |
| 700 | 1 | |a Maier, Joscha |d 1988- |e VerfasserIn |0 (DE-588)1185600868 |0 (DE-627)1664987231 |4 aut | |
| 700 | 1 | |a Ziener, Christian H. |d 1978- |e VerfasserIn |0 (DE-588)137982755 |0 (DE-627)59885309X |0 (DE-576)306117355 |4 aut | |
| 700 | 1 | |a Schlemmer, Heinz-Peter |d 1961- |e VerfasserIn |0 (DE-588)1025559967 |0 (DE-627)722927142 |0 (DE-576)17334805X |4 aut | |
| 700 | 1 | |a Do, Thuy |d 1986- |e VerfasserIn |0 (DE-588)1156815800 |0 (DE-627)1019763485 |0 (DE-576)502462205 |4 aut | |
| 700 | 1 | |a Kauczor, Hans-Ulrich |d 1962- |e VerfasserIn |0 (DE-588)139267123 |0 (DE-627)70327113X |0 (DE-576)310955327 |4 aut | |
| 700 | 1 | |a Schönberg, Stefan |d 1969- |e VerfasserIn |0 (DE-588)131557912 |0 (DE-627)510700624 |0 (DE-576)298584891 |4 aut | |
| 700 | 1 | |a Froelich, Matthias F. |d 1991- |e VerfasserIn |0 (DE-588)1170833756 |0 (DE-627)1040131557 |0 (DE-576)512678359 |4 aut | |
| 700 | 1 | |a Kachelrieß, Marc |d 1969- |e VerfasserIn |0 (DE-588)120866544 |0 (DE-627)705049280 |0 (DE-576)292422725 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Physica medica |d Amsterdam : Elsevier, 1996 |g 139(2025) vom: Nov., Artikel-ID 105208, Seite 1-10 |h Online-Ressource |w (DE-627)364471417 |w (DE-600)2110535-2 |w (DE-576)272350176 |x 1724-191X |7 nnas |a Lung cancer screening CT acquisition protocols for three generations of CT systems conforming to German legislation |
| 773 | 1 | 8 | |g volume:139 |g year:2025 |g month:11 |g elocationid:105208 |g pages:1-10 |g extent:10 |a Lung cancer screening CT acquisition protocols for three generations of CT systems conforming to German legislation |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.ejmp.2025.105208 |x Verlag |x Resolving-System |z kostenfrei |3 Volltext |7 0 |
| 856 | 4 | 0 | |u https://www.sciencedirect.com/science/article/pii/S1120179725003187 |x Verlag |z kostenfrei |3 Volltext |7 0 |
| 951 | |a AR | ||
| 992 | |a 20251209 | ||
| 993 | |a Article | ||
| 994 | |a 2025 | ||
| 998 | |g 120866544 |a Kachelrieß, Marc |m 120866544:Kachelrieß, Marc |d 50000 |e 50000PK120866544 |k 0/50000/ |p 9 |y j | ||
| 998 | |g 1170833756 |a Froelich, Matthias F. |m 1170833756:Froelich, Matthias F. |d 60000 |d 62900 |d 60000 |e 60000PF1170833756 |e 62900PF1170833756 |e 60000PF1170833756 |k 0/60000/ |k 1/60000/62900/ |k 0/60000/ |p 8 | ||
| 998 | |g 131557912 |a Schönberg, Stefan |m 131557912:Schönberg, Stefan |d 60000 |d 62900 |e 60000PS131557912 |e 62900PS131557912 |k 0/60000/ |k 1/60000/62900/ |p 7 | ||
| 998 | |g 139267123 |a Kauczor, Hans-Ulrich |m 139267123:Kauczor, Hans-Ulrich |d 910000 |d 911400 |e 910000PK139267123 |e 911400PK139267123 |k 0/910000/ |k 1/910000/911400/ |p 6 | ||
| 998 | |g 1156815800 |a Do, Thuy |m 1156815800:Do, Thuy |d 910000 |d 911400 |d 50000 |e 910000PD1156815800 |e 911400PD1156815800 |e 50000PD1156815800 |k 0/910000/ |k 1/910000/911400/ |k 0/50000/ |p 5 | ||
| 998 | |g 1025559967 |a Schlemmer, Heinz-Peter |m 1025559967:Schlemmer, Heinz-Peter |d 50000 |e 50000PS1025559967 |k 0/50000/ |p 4 | ||
| 998 | |g 137982755 |a Ziener, Christian H. |m 137982755:Ziener, Christian H. |d 50000 |e 50000PZ137982755 |k 0/50000/ |p 3 | ||
| 998 | |g 1031331298 |a Sawall, Stefan |m 1031331298:Sawall, Stefan |d 50000 |e 50000PS1031331298 |k 0/50000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1945089741 |e 4824652952 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"person":[{"family":"Sawall","display":"Sawall, Stefan","role":"aut","given":"Stefan"},{"role":"aut","given":"Joscha","family":"Maier","display":"Maier, Joscha"},{"family":"Ziener","display":"Ziener, Christian H.","role":"aut","given":"Christian H."},{"given":"Heinz-Peter","role":"aut","family":"Schlemmer","display":"Schlemmer, Heinz-Peter"},{"given":"Thuy","role":"aut","display":"Do, Thuy","family":"Do"},{"family":"Kauczor","display":"Kauczor, Hans-Ulrich","given":"Hans-Ulrich","role":"aut"},{"given":"Stefan","role":"aut","display":"Schönberg, Stefan","family":"Schönberg"},{"role":"aut","given":"Matthias F.","family":"Froelich","display":"Froelich, Matthias F."},{"role":"aut","given":"Marc","family":"Kachelrieß","display":"Kachelrieß, Marc"}],"language":["eng"],"title":[{"title_sort":"Lung cancer screening CT acquisition protocols for three generations of CT systems conforming to German legislation","title":"Lung cancer screening CT acquisition protocols for three generations of CT systems conforming to German legislation"}],"note":["Online verfügbar: 24. Oktober 2025, Artikelversion: 24. Oktober 2025","Gesehen am 09.12.2025"],"origin":[{"dateIssuedKey":"2025","dateIssuedDisp":"November 2025"}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"relHost":[{"origin":[{"publisherPlace":"Amsterdam ; Pisa","dateIssuedKey":"1996","publisher":"Elsevier ; Istituti Editoriali e Poligrafici Internazionali","dateIssuedDisp":"1996-"}],"pubHistory":["Nachgewiesen 12.1996 -"],"note":["Fortsetzung der Druck-Ausgabe","Gesehen am 12.11.2021"],"title":[{"title_sort":"Physica medica","subtitle":"European journal of medical physics ; an international journal devoted to the applications of physics to medicine and biology","title":"Physica medica"}],"type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Lung cancer screening CT acquisition protocols for three generations of CT systems conforming to German legislationPhysica medica","physDesc":[{"extent":"Online-Ressource"}],"recId":"364471417","id":{"issn":["1724-191X"],"zdb":["2110535-2"],"eki":["364471417"]},"language":["eng"],"part":{"volume":"139","text":"139(2025) vom: Nov., Artikel-ID 105208, Seite 1-10","extent":"10","year":"2025","pages":"1-10"}}],"recId":"1945089741","physDesc":[{"extent":"10 S.","noteIll":"Illustrationen, Diagramme"}],"name":{"displayForm":["Stefan Sawall, Joscha Maier, Christian H. Ziener, Heinz-Peter Schlemmer, Thuy D. Do, Hans-Ulrich Kauczor, Stefan O. Schoenberg, Matthias F. Froelich, Marc Kachelrieß"]},"id":{"doi":["10.1016/j.ejmp.2025.105208"],"eki":["1945089741"]}} | ||
| SRT | |a SAWALLSTEFLUNGCANCER2025 | ||