Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centers

Objectives - To evaluate the accuracy of 3D-printed models and positional trueness of the removable dies. - Methods - A typodont incisor, canine, premolar, and molar were prepared for single crowns and digitized. Based on this scan, two sets of models (n = 10 each) were 3D-printed in two milling cen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schwindling, Maria (VerfasserIn) , Herpel, Christopher (VerfasserIn) , Schwindling, Franz Sebastian (VerfasserIn) , Kapferer-Seebacher, Ines (VerfasserIn) , Vogel, Lorenz (VerfasserIn) , Steiner, René (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 2025
In: Journal of dentistry
Year: 2025, Jahrgang: 161, Pages: 1-5
ISSN:1879-176X
DOI:10.1016/j.jdent.2025.105986
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.jdent.2025.105986
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0300571225004300
Volltext
Verfasserangaben:Maria Schwindling, Christopher Herpel, Franz Sebastian Schwindling, Ines Kapferer-Seebacher, Lorenz Vogel, René Steiner

MARC

LEADER 00000naa a2200000 c 4500
001 194512931X
003 DE-627
005 20251209121029.0
007 cr uuu---uuuuu
008 251209s2025 xx |||||o 00| ||eng c
024 7 |a 10.1016/j.jdent.2025.105986  |2 doi 
035 |a (DE-627)194512931X 
035 |a (DE-599)KXP194512931X 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schwindling, Maria  |e VerfasserIn  |0 (DE-588)1383833214  |0 (DE-627)1945137436  |4 aut 
245 1 0 |a Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centers  |c Maria Schwindling, Christopher Herpel, Franz Sebastian Schwindling, Ines Kapferer-Seebacher, Lorenz Vogel, René Steiner 
264 1 |c October 2025 
300 |b Illustrationen, Diagramme 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Online verfügbar 22 July 2025, Version des Artikels 2 August 2025 
500 |a Gesehen am 09.12.2025 
520 |a Objectives - To evaluate the accuracy of 3D-printed models and positional trueness of the removable dies. - Methods - A typodont incisor, canine, premolar, and molar were prepared for single crowns and digitized. Based on this scan, two sets of models (n = 10 each) were 3D-printed in two milling centers, resulting in a total of 80 dies. The two model types varied in die configuration (conical and root-formed), resin type, and post-processing techniques. Fabrication accuracy was evaluated after model delivery. The positional trueness was measured at baseline, after 10 and 50 repositioning cycles, by evaluating metric and angular die displacements. Deviations were compared between the groups using non-parametric Mann-Whitney-U tests at a significance level of 0.05. - Results - Fabrication accuracy was similar for the two model sets. Trueness/precision were 72 ± 15 µm/76 ± 19 µm for center 1. For center 2, the corresponding values were 60 ± 5 µm/79 ± 4 µm. Significant differences in positional trueness were observed between the two model types after both 10 and 50 repositioning cycles. After 10 cycles, mean die displacements were 78 ± 76 µm for center 1 and 526 ± 470 µm for center 2 (p < 0.001). These values showed minimal variation after 50 cycles, with mean die displacements of 98 ± 80 µm for center 1 and 470 ± 386 µm for center 2 (p < 0.001). Angular deviations were minimal for both groups, even after 50 cycles, with deviations below 1°. - Conclusion - While the accuracy of the 3D-printed models was adequate, the positional trueness of the dies requires improvement, as some currently available models demonstrate unacceptable discrepancies. - Clinical significance - The quality of 3D-printed models with removable dies for CAD/CAM crowns can vary substantially between milling centers. While some models can merely serve as restoration carriers, others are equipped with accurate dies that can be removed and repositioned reliably. 
650 4 |a 3D printing 
650 4 |a Accuracy 
650 4 |a Additive manufacturing 
650 4 |a Dental restoration 
650 4 |a Positional trueness 
650 4 |a Removable dies 
700 1 |a Herpel, Christopher  |e VerfasserIn  |0 (DE-588)1233302191  |0 (DE-627)1757635084  |4 aut 
700 1 |a Schwindling, Franz Sebastian  |e VerfasserIn  |4 aut 
700 1 |a Kapferer-Seebacher, Ines  |e VerfasserIn  |4 aut 
700 1 |a Vogel, Lorenz  |e VerfasserIn  |0 (DE-588)1249225566  |0 (DE-627)1785749706  |4 aut 
700 1 |a Steiner, René  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Journal of dentistry  |d Amsterdam [u.a.] : Elsevier Science, 1972  |g 161(2025) vom: Okt., Artikel-ID 105986, Seite 1-5  |h Online-Ressource  |w (DE-627)320456757  |w (DE-600)2006760-4  |w (DE-576)09101770X  |x 1879-176X  |7 nnas  |a Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centers 
773 1 8 |g volume:161  |g year:2025  |g month:10  |g elocationid:105986  |g pages:1-5  |g extent:5  |a Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centers 
856 4 0 |u https://doi.org/10.1016/j.jdent.2025.105986  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext  |7 0 
856 4 0 |u https://www.sciencedirect.com/science/article/pii/S0300571225004300  |x Verlag  |z kostenfrei  |3 Volltext  |7 0 
951 |a AR 
992 |a 20251209 
993 |a Article 
994 |a 2025 
998 |g 1249225566  |a Vogel, Lorenz  |m 1249225566:Vogel, Lorenz  |d 130000  |d 130300  |e 130000PV1249225566  |e 130300PV1249225566  |k 0/130000/  |k 1/130000/130300/  |p 5 
998 |g 1233302191  |a Herpel, Christopher  |m 1233302191:Herpel, Christopher  |d 910000  |d 910800  |d 50000  |e 910000PH1233302191  |e 910800PH1233302191  |e 50000PH1233302191  |k 0/910000/  |k 1/910000/910800/  |k 0/50000/  |p 2 
999 |a KXP-PPN194512931X  |e 4824695848 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"doi":["10.1016/j.jdent.2025.105986"],"eki":["194512931X"]},"origin":[{"dateIssuedDisp":"October 2025","dateIssuedKey":"2025"}],"name":{"displayForm":["Maria Schwindling, Christopher Herpel, Franz Sebastian Schwindling, Ines Kapferer-Seebacher, Lorenz Vogel, René Steiner"]},"relHost":[{"origin":[{"publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier Science","dateIssuedKey":"1972","dateIssuedDisp":"1972-"}],"id":{"issn":["1879-176X"],"zdb":["2006760-4"],"eki":["320456757"]},"physDesc":[{"extent":"Online-Ressource"}],"title":[{"title_sort":"Journal of dentistry","title":"Journal of dentistry"}],"note":["Gesehen am 04.05.07"],"disp":"Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centersJournal of dentistry","type":{"bibl":"periodical","media":"Online-Ressource"},"language":["eng"],"recId":"320456757","pubHistory":["1.1972 -"],"part":{"extent":"5","text":"161(2025) vom: Okt., Artikel-ID 105986, Seite 1-5","volume":"161","pages":"1-5","year":"2025"}}],"physDesc":[{"noteIll":"Illustrationen, Diagramme","extent":"5 S."}],"title":[{"title_sort":"Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centers","title":"Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centers"}],"person":[{"given":"Maria","family":"Schwindling","role":"aut","roleDisplay":"VerfasserIn","display":"Schwindling, Maria"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Herpel, Christopher","given":"Christopher","family":"Herpel"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Schwindling, Franz Sebastian","given":"Franz Sebastian","family":"Schwindling"},{"family":"Kapferer-Seebacher","given":"Ines","display":"Kapferer-Seebacher, Ines","roleDisplay":"VerfasserIn","role":"aut"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Vogel, Lorenz","given":"Lorenz","family":"Vogel"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Steiner, René","given":"René","family":"Steiner"}],"recId":"194512931X","language":["eng"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"note":["Online verfügbar 22 July 2025, Version des Artikels 2 August 2025","Gesehen am 09.12.2025"]} 
SRT |a SCHWINDLINACCURACYOF2025