Hybrid compton-PET imaging for ion-range verification: a preclinical study for proton, helium, and carbon therapy at HIT

Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gamma imaging (PGI) are two of the most promising and researched methodologies, both of them with their own advantages and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Balibrea-Correa, Javier (VerfasserIn) , Lerendegui-Marco, Jorge (VerfasserIn) , Ladarescu, Ion (VerfasserIn) , Morell, Sergio (VerfasserIn) , Guerrero, Carlos (VerfasserIn) , Rodríguez-González, Teresa (VerfasserIn) , Jiménez-Ramos, Maria del Carmen (VerfasserIn) , Quesada, Jose Manuel (VerfasserIn) , Bauer, Julia (VerfasserIn) , Brons, Stephan (VerfasserIn) , Domingo-Pardo, César (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 11 September 2025
In: The European physical journal. Plus
Year: 2025, Jahrgang: 140, Heft: 9, Pages: 1-18
ISSN:2190-5444
DOI:10.1140/epjp/s13360-025-06817-9
Online-Zugang:Verlag, kostenfrei, Volltext: https://doi.org/10.1140/epjp/s13360-025-06817-9
Volltext
Verfasserangaben:Javier Balibrea-Correa, Jorge Lerendegui-Marco, Ion Ladarescu, Sergio Morell, Carlos Guerrero, Teresa Rodríguez-González, Maria del Carmen Jiménez-Ramos, Jose Manuel Quesada, Julia Bauer, Stephan Brons, César Domingo-Pardo

MARC

LEADER 00000naa a2200000 c 4500
001 1950181014
003 DE-627
005 20260126103452.0
007 cr uuu---uuuuu
008 260126s2025 xx |||||o 00| ||eng c
024 7 |a 10.1140/epjp/s13360-025-06817-9  |2 doi 
035 |a (DE-627)1950181014 
035 |a (DE-599)KXP1950181014 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Balibrea-Correa, Javier  |e VerfasserIn  |0 (DE-588)1387970062  |0 (DE-627)1950182770  |4 aut 
245 1 0 |a Hybrid compton-PET imaging for ion-range verification  |b a preclinical study for proton, helium, and carbon therapy at HIT  |c Javier Balibrea-Correa, Jorge Lerendegui-Marco, Ion Ladarescu, Sergio Morell, Carlos Guerrero, Teresa Rodríguez-González, Maria del Carmen Jiménez-Ramos, Jose Manuel Quesada, Julia Bauer, Stephan Brons, César Domingo-Pardo 
264 1 |c 11 September 2025 
300 |b Illustrationen, Diagramme 
300 |a 18 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 26.01.2026 
520 |a Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gamma imaging (PGI) are two of the most promising and researched methodologies, both of them with their own advantages and challenges. Thus far, both of them have been explored for ion-range verification in an independent way. However, the simultaneous combination of PET and PGI within the same imaging framework may open-up the possibility to exploit more efficiently all radiative emissions excited in the tissue by the ion beam. Here, we report on the first preclinical implementation of an hybrid PET-PGI imaging system, hereby exploring its performance over several ion beam species (H, He and C), energies (55-275 MeV) and intensities ($$10^7$$-$$10^9$$ions/spot), which are representative of clinical conditions. The measurements were carried out using the pencil-beam scanning technique at the synchrotron accelerator of the heavy ion therapy center in Heidelberg utilizing an array of four Compton cameras in a twofold front-to-front configuration. The results demonstrate that the hybrid PET-PGI technique can be well suited for relatively low energies (55-155 MeV) and beams of protons. On the other hand, for heavier beams of helium and carbon ions at higher energies (155-275 MeV), range monitoring becomes more challenging owing to large backgrounds from additional nuclear processes. The experimental results are well understood on the basis of realistic Monte Carlo calculations, which show a satisfactory agreement with the measured data. This work can guide further upgrades of the hybrid PET-PGI system toward a clinical implementation of this innovative technique. 
700 1 |a Lerendegui-Marco, Jorge  |e VerfasserIn  |4 aut 
700 1 |a Ladarescu, Ion  |e VerfasserIn  |4 aut 
700 1 |a Morell, Sergio  |e VerfasserIn  |4 aut 
700 1 |a Guerrero, Carlos  |e VerfasserIn  |4 aut 
700 1 |a Rodríguez-González, Teresa  |e VerfasserIn  |4 aut 
700 1 |a Jiménez-Ramos, Maria del Carmen  |e VerfasserIn  |4 aut 
700 1 |a Quesada, Jose Manuel  |e VerfasserIn  |4 aut 
700 1 |a Bauer, Julia  |e VerfasserIn  |0 (DE-588)107489099X  |0 (DE-627)832650145  |0 (DE-576)443090904  |4 aut 
700 1 |a Brons, Stephan  |e VerfasserIn  |4 aut 
700 1 |a Domingo-Pardo, César  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t The European physical journal. Plus  |d Berlin : Springer, 2011  |g 140(2025), 9, Artikel-ID 870, Seite 1-18  |h Online-Ressource  |w (DE-627)647653958  |w (DE-600)2595693-0  |w (DE-576)338208267  |x 2190-5444  |7 nnas  |a Hybrid compton-PET imaging for ion-range verification a preclinical study for proton, helium, and carbon therapy at HIT 
773 1 8 |g volume:140  |g year:2025  |g number:9  |g elocationid:870  |g pages:1-18  |g extent:18  |a Hybrid compton-PET imaging for ion-range verification a preclinical study for proton, helium, and carbon therapy at HIT 
856 4 0 |u https://doi.org/10.1140/epjp/s13360-025-06817-9  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext  |7 0 
951 |a AR 
992 |a 20260126 
993 |a Article 
994 |a 2025 
998 |g 107489099X  |a Bauer, Julia  |m 107489099X:Bauer, Julia  |d 60000  |e 60000PB107489099X  |k 0/60000/  |p 9 
999 |a KXP-PPN1950181014  |e 4860257685 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"language":["eng"],"origin":[{"dateIssuedDisp":"2011-","publisherPlace":"Berlin ; Heidelberg","publisher":"Springer","dateIssuedKey":"2011"}],"note":["Gesehen am 04.05.2023"],"type":{"bibl":"periodical","media":"Online-Ressource"},"titleAlt":[{"title":"The European physical journal / Plus"},{"title":"EPJ Plus"}],"title":[{"title_sort":"European physical journal","partname":"Plus","title":"The European physical journal"}],"part":{"issue":"9","pages":"1-18","text":"140(2025), 9, Artikel-ID 870, Seite 1-18","year":"2025","volume":"140","extent":"18"},"disp":"Hybrid compton-PET imaging for ion-range verification a preclinical study for proton, helium, and carbon therapy at HITThe European physical journal. Plus","id":{"zdb":["2595693-0"],"issn":["2190-5444"],"eki":["647653958"]},"pubHistory":["126.2011 -"],"recId":"647653958","physDesc":[{"extent":"Online-Ressource"}]}],"id":{"doi":["10.1140/epjp/s13360-025-06817-9"],"eki":["1950181014"]},"name":{"displayForm":["Javier Balibrea-Correa, Jorge Lerendegui-Marco, Ion Ladarescu, Sergio Morell, Carlos Guerrero, Teresa Rodríguez-González, Maria del Carmen Jiménez-Ramos, Jose Manuel Quesada, Julia Bauer, Stephan Brons, César Domingo-Pardo"]},"physDesc":[{"noteIll":"Illustrationen, Diagramme","extent":"18 S."}],"recId":"1950181014","type":{"media":"Online-Ressource","bibl":"article-journal"},"note":["Gesehen am 26.01.2026"],"origin":[{"dateIssuedDisp":"11 September 2025","dateIssuedKey":"2025"}],"title":[{"title":"Hybrid compton-PET imaging for ion-range verification","subtitle":"a preclinical study for proton, helium, and carbon therapy at HIT","title_sort":"Hybrid compton-PET imaging for ion-range verification"}],"language":["eng"],"person":[{"given":"Javier","role":"aut","family":"Balibrea-Correa","display":"Balibrea-Correa, Javier"},{"display":"Lerendegui-Marco, Jorge","family":"Lerendegui-Marco","given":"Jorge","role":"aut"},{"display":"Ladarescu, Ion","family":"Ladarescu","role":"aut","given":"Ion"},{"family":"Morell","display":"Morell, Sergio","role":"aut","given":"Sergio"},{"given":"Carlos","role":"aut","display":"Guerrero, Carlos","family":"Guerrero"},{"display":"Rodríguez-González, Teresa","family":"Rodríguez-González","role":"aut","given":"Teresa"},{"given":"Maria del Carmen","role":"aut","display":"Jiménez-Ramos, Maria del Carmen","family":"Jiménez-Ramos"},{"role":"aut","given":"Jose Manuel","display":"Quesada, Jose Manuel","family":"Quesada"},{"family":"Bauer","display":"Bauer, Julia","role":"aut","given":"Julia"},{"role":"aut","given":"Stephan","display":"Brons, Stephan","family":"Brons"},{"family":"Domingo-Pardo","display":"Domingo-Pardo, César","role":"aut","given":"César"}]} 
SRT |a BALIBREACOHYBRIDCOMP1120