Magnetic resonance imaging-guided focused ultrasound lesioning under general anesthesia: a case series

Introduction: Real-time monitoring during MR-guided focused ultrasound (MRgFUS) procedures has been considered essential to monitor tremor improvement and side effects in the alignment and/or verify phase before the actual MRgFUS treatment and following the ablative sonications. However, a subgroup...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Schmidt, Franziska (VerfasserIn) , Buongermini, Rafael E. (VerfasserIn) , Germann, Jürgen (VerfasserIn) , Hajiabadi, Mohammad Mehdi (VerfasserIn) , Bichsel, Oliver (VerfasserIn) , Sarica, Can (VerfasserIn) , Darmani, Ghazaleh (VerfasserIn) , Fasano, Alfonso (VerfasserIn) , Boutet, Alexandre (VerfasserIn) , Lozano, Andres M. (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: October 28 2025
In: Stereotactic and functional neurosurgery
Year: 2025, Pages: ?
ISSN:1423-0372
DOI:10.1159/000549057
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1159/000549057
Volltext
Verfasserangaben:Franziska A. Schmidt, Rafael E. Buongermini, Jürgen Germann, Mohammad Mehdi Hajiabadi, Oliver Bichsel, Can Sarica, Ghazaleh Darmani, Alfonso Fasano, Alexandre Boutet, Andres M. Lozano

MARC

LEADER 00000naa a22000002c 4500
001 196311616X
003 DE-627
005 20260227092101.0
007 cr uuu---uuuuu
008 260227s2025 xx |||||o 00| ||eng c
024 7 |a 10.1159/000549057  |2 doi 
035 |a (DE-627)196311616X 
035 |a (DE-599)KXP196311616X 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Schmidt, Franziska  |e VerfasserIn  |0 (DE-588)1388217538  |0 (DE-627)1950486044  |4 aut 
245 1 0 |a Magnetic resonance imaging-guided focused ultrasound lesioning under general anesthesia  |b a case series  |c Franziska A. Schmidt, Rafael E. Buongermini, Jürgen Germann, Mohammad Mehdi Hajiabadi, Oliver Bichsel, Can Sarica, Ghazaleh Darmani, Alfonso Fasano, Alexandre Boutet, Andres M. Lozano 
264 1 |c October 28 2025 
300 |a ? 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Veröffentlicht: 28. Oktober 2025 
500 |a Gesehen am 27.02.2026 
520 |a Introduction: Real-time monitoring during MR-guided focused ultrasound (MRgFUS) procedures has been considered essential to monitor tremor improvement and side effects in the alignment and/or verify phase before the actual MRgFUS treatment and following the ablative sonications. However, a subgroup of patients does not tolerate being awake during the entire procedure for a variety of reasons. Case Presentations: We performed MRgFUS treatments in three Parkinson’s disease/Parkinsonism patients under general anesthesia. These patients had previously failed an attempt to undergo the procedure awake. All 3 patients who had the procedure under general anesthesia experienced significant improvement of their symptoms and experienced only transient adverse effects (e.g., balance problems, left facial droop) that were no longer evident at their first postoperative visit. Conclusion: Our findings suggest that MRgFUS treatment under general anesthesia could possibly be done safely and may represent a valid therapeutic option for patients unable to tolerate the procedure awake. 
700 1 |a Buongermini, Rafael E.  |e VerfasserIn  |4 aut 
700 1 |a Germann, Jürgen  |e VerfasserIn  |4 aut 
700 1 |a Hajiabadi, Mohammad Mehdi  |e VerfasserIn  |0 (DE-588)1212532465  |0 (DE-627)1702043991  |4 aut 
700 1 |a Bichsel, Oliver  |e VerfasserIn  |4 aut 
700 1 |a Sarica, Can  |e VerfasserIn  |4 aut 
700 1 |a Darmani, Ghazaleh  |e VerfasserIn  |4 aut 
700 1 |a Fasano, Alfonso  |e VerfasserIn  |4 aut 
700 1 |a Boutet, Alexandre  |e VerfasserIn  |4 aut 
700 1 |a Lozano, Andres M.  |e VerfasserIn  |4 aut 
773 0 8 |i Enthalten in  |t Stereotactic and functional neurosurgery  |d Basel : Karger, 1998  |g (2025), Seite ?  |h Online-Ressource  |w (DE-627)300897820  |w (DE-600)1483576-9  |w (DE-576)113025491  |x 1423-0372  |7 nnas  |a Magnetic resonance imaging-guided focused ultrasound lesioning under general anesthesia a case series 
773 1 8 |g year:2025  |g pages:?  |g extent:?  |a Magnetic resonance imaging-guided focused ultrasound lesioning under general anesthesia a case series 
856 4 0 |u https://doi.org/10.1159/000549057  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext  |7 1 
951 |a AR 
992 |a 20260227 
993 |a Article 
994 |a 2025 
998 |g 1212532465  |a Hajiabadi, Mohammad Mehdi  |m 1212532465:Hajiabadi, Mohammad Mehdi  |d 910000  |d 911200  |e 910000PH1212532465  |e 911200PH1212532465  |k 0/910000/  |k 1/910000/911200/  |p 4 
999 |a KXP-PPN196311616X  |e 4923294566 
BIB |a Y 
SER |a journal 
JSO |a {"origin":[{"dateIssuedDisp":"October 28 2025","dateIssuedKey":"2025"}],"person":[{"role":"aut","display":"Schmidt, Franziska","family":"Schmidt","given":"Franziska"},{"role":"aut","family":"Buongermini","display":"Buongermini, Rafael E.","given":"Rafael E."},{"role":"aut","given":"Jürgen","display":"Germann, Jürgen","family":"Germann"},{"given":"Mohammad Mehdi","display":"Hajiabadi, Mohammad Mehdi","family":"Hajiabadi","role":"aut"},{"given":"Oliver","family":"Bichsel","display":"Bichsel, Oliver","role":"aut"},{"role":"aut","family":"Sarica","display":"Sarica, Can","given":"Can"},{"family":"Darmani","display":"Darmani, Ghazaleh","given":"Ghazaleh","role":"aut"},{"role":"aut","given":"Alfonso","family":"Fasano","display":"Fasano, Alfonso"},{"display":"Boutet, Alexandre","family":"Boutet","given":"Alexandre","role":"aut"},{"role":"aut","given":"Andres M.","display":"Lozano, Andres M.","family":"Lozano"}],"physDesc":[{"extent":"? S."}],"name":{"displayForm":["Franziska A. Schmidt, Rafael E. Buongermini, Jürgen Germann, Mohammad Mehdi Hajiabadi, Oliver Bichsel, Can Sarica, Ghazaleh Darmani, Alfonso Fasano, Alexandre Boutet, Andres M. Lozano"]},"title":[{"title":"Magnetic resonance imaging-guided focused ultrasound lesioning under general anesthesia","title_sort":"Magnetic resonance imaging-guided focused ultrasound lesioning under general anesthesia","subtitle":"a case series"}],"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"disp":"Magnetic resonance imaging-guided focused ultrasound lesioning under general anesthesia a case seriesStereotactic and functional neurosurgery","origin":[{"publisherPlace":"Basel","dateIssuedDisp":"1998-","publisher":"Karger","dateIssuedKey":"1998"}],"part":{"pages":"?","text":"(2025), Seite ?","year":"2025","extent":"?"},"id":{"zdb":["1483576-9"],"issn":["1423-0372"],"eki":["300897820"]},"note":["Gesehen am 29.10.25"],"type":{"bibl":"periodical","media":"Online-Ressource"},"recId":"300897820","language":["eng"],"title":[{"title":"Stereotactic and functional neurosurgery","subtitle":"official journal of the World Society for Stereotactic and Functional Neurosurgery : official journal of the American Society for Stereotactic and Functional Neurosurgery","title_sort":"Stereotactic and functional neurosurgery"}],"pubHistory":["Volume 52, issue 1 (1989)-"]}],"language":["eng"],"recId":"196311616X","type":{"bibl":"article-journal","media":"Online-Ressource"},"id":{"eki":["196311616X"],"doi":["10.1159/000549057"]},"note":["Veröffentlicht: 28. Oktober 2025","Gesehen am 27.02.2026"]} 
SRT |a SCHMIDTFRAMAGNETICRE2820