Characterization of a novel plastic scintillation detector for in vivo electron dosimetry

Introduction Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSDs) promise high spatial resolution and real-time dosimetry with minimum perturbation of the radiation field. This study characterizes a novel PSD in an electro...

Full description

Saved in:
Bibliographic Details
Main Authors: Bauer, Cornelius Jonathan (Author) , Schneider, Frank (Author) , Göbel, Ida Dorothea (Author) , Oppitz, Hans (Author) , Giordano, Frank Anton (Author) , Fleckenstein, Jens (Author)
Format: Article (Journal)
Language:English
Published: May 2026
In: Journal of applied clinical medical physics
Year: 2026, Volume: 27, Issue: 5, Pages: 1-11
ISSN:1526-9914
DOI:10.1002/acm2.70623
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1002/acm2.70623
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/acm2.70623
Get full text
Author Notes:Cornelius J. Bauer, Frank Schneider, Ida D. Göbel, Hans Oppitz, Frank A. Giordano, Jens Fleckenstein
Description
Summary:Introduction Real-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSDs) promise high spatial resolution and real-time dosimetry with minimum perturbation of the radiation field. This study characterizes a novel PSD in an electron beam to determine its suitability for in vivo dosimetry. Methods Dual-channel Cherenkov radiation correction and dosimetric characterization of the PSD were investigated using reference ionization chambers. Percentage depth-dose curves, lateral profiles, and output factors were compared with reference ionization chamber measurements. Surface doses were measured on solid water and on an anthropomorphic phantom and were compared to ionization chamber and radiochromic film measurements. Results The investigated PSD demonstrated clinically acceptable linearity, dose rate independence, isotropy and reproducibility (total variation < 2%). Dosimetric deviations in R50 and R80 were below 1.0 mm and lateral profiles agreed with a mean absolute error below 1.5%. Small field measurements were within 2% of the reference ionization chamber results. Surface dose measurements had mean relative deviations of 1.3% from ionization chamber measurements and 2.1% from radiochromic film measurements. Conclusion The PSD investigated in this study is suitable for clinically acceptable electron beam dosimetry and provides accurate dosimetric results for surface dose measurements. It has the potential to be used for real-time in vivo dosimetry.
Item Description:Erstmals veröffentlicht: 12. Mai 2026
Gesehen am 09.06.2026
Physical Description:Online Resource
ISSN:1526-9914