Perimetry Update 1998/1999

The topics presented at the XIIIth Symposium embraced all aspects of perimetric science. A total of ten sessions were held and covered: fundamentals of perimetry, visual psychophysics, new perimetric techniques, new algorithms for estimating threshold, perimetric variability, color perimetry, optic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Weitere Verfasser: Wall, M. (HerausgeberIn) , Wild, J. M. (HerausgeberIn)
Dokumenttyp: Buch/Monographie
Sprache:Englisch
Veröffentlicht: The Hague SPB Academic Publishing BV 1999
Schriftenreihe:International Perimetric Society
Volumes / Articles: Show Volumes / Articles.
Schlagworte:
Online-Zugang:Aggregator, Volltext: https://ebookcentral.proquest.com/lib/kxp/detail.action?docID=309971
Volltext
Verfasserangaben:ed. by M. Wall, J. M. Wild

MARC

LEADER 00000cam a22000002c 4500
001 722746814
003 DE-627
005 20240716192307.0
007 cr uuu---uuuuu
008 120830s1999 xx |||||o 00| ||eng c
020 |a 9789062991556  |9 978-90-6299-155-6 
035 |a (DE-627)722746814 
035 |a (DE-576)9722746812 
035 |a (DE-599)GBV722746814 
035 |a (EBC)EBC309971 
035 |a (DE-627-1)027998835 
040 |a DE-627  |b ger  |c DE-627  |e rakwb 
041 |a eng 
050 0 |a RE54 
082 0 |a 600 
084 |a 33  |2 sdnb 
084 |a 35  |2 sdnb 
245 0 0 |a Perimetry Update 1998/1999  |c ed. by M. Wall, J. M. Wild 
264 1 |a The Hague  |b SPB Academic Publishing BV  |c 1999 
300 |a Online-Ressource (553 p.) 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
490 0 |a International Perimetric Society 
500 |a Description based upon print version of record 
505 8 |a Contents; Preface; New perimetry algorithms; Sensitivity to glaucomatous visual field loss in full threshold, SITA Standard, and SITA Fast tests; Characteristics of the SITA program on the Humphrey Visual Field Analyzer; Comparing SITA and full threshold strategies; Comparison of SITA and dynamic strategies with the same examination grid; A comparison of light detection thresholds in glaucomatous visual fields in SITA-S and Fastpac; Comparative evaluation of four strategies (standard, dynamic, TOP, 2-level) using the automated perimeter Octopus 1-2-3 
505 8 |a G1-tendency-oriented perimetry: introduction and comparison with G1-Standard BracketingReproducibility of top algorithm results versus those obtained with the bracketing procedure; Flicker-top perimetry in normals and patients with ocular hypertension and early glaucoma; New methods - screening; Efficacy of screening modes of FDT and Dicon perimeters; Frequency doubling perimetry as a glaucoma screener; A comparison of the effects of neutral density filters and diffusing filters on motion detection perimetry, white-on-white perimetry and frequency doubling perimetry 
505 8 |a Automated flicker perimetry in glaucoma and retinal detachment patientsVariability; The relationship between sensitivity and variability in normal and glaucomatous visual fields; Evaluation of two screening tests for frequency doubling technology perimetry; A method for sampling discrete ganglion cell mosaics that decreases hreshold variability; Quantification of glaucomatous threshold visual field loss based on neuromorphometric correlates; Linear regression analysis in glaucoma visual field follow-up; Detecting gradual and sudden sensitivity loss in series of visual fields 
505 8 |a Pointwise linear regression of glaucomatous visual fields: a new approachThe rate of visual field progression during long-term follow-up of normal-tension glaucoma patients; Evaluation of fixation during perimetry using a new fundus perimeter; The effect of a 'social' dose of alcohol on the central retinal sensitivity and fixation stability - measured with the scanning laser ophthalmoscope; Psychophysics; The independence of perimetry thresholds; Detection and resolution thresholds in the fovea and periphery for high-pass tumbling E's; Tumbling E resolution perimetry in glaucoma 
505 8 |a Comparison between threshold pupil perimetry and suprathreshold pupil perimetryBinocular summation within the binocular visual field; Abnormal maximum line displacement sensitivity and frequency-of-seeing curves for a motion stimulus in glaucoma; Intensity distribution beneath an artificial vessel: implications for angioscotomata; Fundamentals of perimetry; Age influences asymmetry in differential luminance sensitivity; Age and eccentricity effects on grating detection and grating resolution automated perimetry 
505 8 |a Effect of localized refractive error on perimetric thresholds for differentsized targets in foveal and peripheral vision 
520 |a The topics presented at the XIIIth Symposium embraced all aspects of perimetric science. A total of ten sessions were held and covered: fundamentals of perimetry, visual psychophysics, new perimetric techniques, new algorithms for estimating threshold, perimetric variability, color perimetry, optic nerve head imaging, and visual field investigation in glaucoma and in retinal and neurological disorders. The new perimetric techniques included frequency doubling technology, flicker perimetry and pupil perimetry. The new algorithms included the Swedish Interactive Threshold Algorithm (SITA) and Te 
650 4 |a Perimetry ; Congresses 
650 4 |a Electronic books 
655 0 |a Electronic books 
700 1 |a Wall, M.  |e Hrsg.  |4 edt 
700 1 |a Wild, J. M.  |e Hrsg.  |4 edt 
776 1 |z 9789062997756  |c  : 122 (NL) 
776 1 |z 9789062991556 
776 0 8 |i Erscheint auch als  |n Druck-Ausgabe  |a Perimetry Update 1998/1999 
856 4 0 |u https://ebookcentral.proquest.com/lib/kxp/detail.action?docID=309971  |x Aggregator  |3 Volltext 
912 |a ZDB-30-PAD 
912 |a ZDB-30-PQE 
951 |a BO 
992 |a 20210303 
999 |a KXP-PPN722746814  |e 3880744688 
BIB |a Y 
SPR |a Y 
JSO |a {"recId":"722746814","language":["eng"],"note":["Description based upon print version of record"],"type":{"media":"Online-Ressource","bibl":"edited-book"},"physDesc":[{"extent":"Online-Ressource (553 p.)"}],"id":{"eki":["722746814"],"isbn":["9789062991556"]},"title":[{"title_sort":"Perimetry Update 1998/1999","title":"Perimetry Update 1998/1999"}],"origin":[{"publisherPlace":"The Hague","dateIssuedDisp":"1999","dateIssuedKey":"1999","publisher":"SPB Academic Publishing BV"}],"name":{"displayForm":["ed. by M. Wall, J. M. Wild"]},"person":[{"family":"Wall","given":"M.","roleDisplay":"Hrsg.","display":"Wall, M.","role":"edt"},{"family":"Wild","given":"J. M.","roleDisplay":"Hrsg.","display":"Wild, J. M.","role":"edt"}]} 
SRT |a PERIMETRYU1999