Optimized protocol for high resolution functional magnetic resonance imaging at 3T using single-shot echo planar imaging
To translate highly accelerated EPI-fMRI protocols as commonly used at ultra-high field strengths to clinical 3T settings. EPI protocols with increasing matrix sizes and parallel imaging (PI) factors were tested in two separate fMRI studies, a simple motor-task and a complex motivation-task experime...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
15 January 2015
|
| In: |
Journal of neuroscience methods
Year: 2015, Volume: 239, Pages: 170-182 |
| ISSN: | 1872-678X |
| DOI: | 10.1016/j.jneumeth.2014.10.014 |
| Online Access: | Verlag, Volltext: http://dx.doi.org/10.1016/j.jneumeth.2014.10.014 Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0165027014003811 |
| Author Notes: | Sebastian Domsch, Jascha Zapp, Lothar R. Schad, Frauke Nees, Holger Hill, Derik Hermann, Karl Mann, Sabine Vollstädt-Klein |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1560532327 | ||
| 003 | DE-627 | ||
| 005 | 20250416112805.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 170706s2015 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jneumeth.2014.10.014 |2 doi | |
| 035 | |a (DE-627)1560532327 | ||
| 035 | |a (DE-576)490532322 | ||
| 035 | |a (DE-599)BSZ490532322 | ||
| 035 | |a (OCoLC)1340976622 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Domsch, Sebastian |d 1981- |e VerfasserIn |0 (DE-588)103361016X |0 (DE-627)742070964 |0 (DE-576)381227855 |4 aut | |
| 245 | 1 | 0 | |a Optimized protocol for high resolution functional magnetic resonance imaging at 3T using single-shot echo planar imaging |c Sebastian Domsch, Jascha Zapp, Lothar R. Schad, Frauke Nees, Holger Hill, Derik Hermann, Karl Mann, Sabine Vollstädt-Klein |
| 264 | 1 | |c 15 January 2015 | |
| 300 | |a 13 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 06.07.2017 | ||
| 520 | |a To translate highly accelerated EPI-fMRI protocols as commonly used at ultra-high field strengths to clinical 3T settings. EPI protocols with increasing matrix sizes and parallel imaging (PI) factors were tested in two separate fMRI studies, a simple motor-task and a complex motivation-task experiment with focus on the sensorimotor cortex (SMC) and the nucleus accumbens (NAcc), respectively. By increasing the matrix size and the PI-factor simultaneously, BOLD-sensitivity in terms of maximal t-values and numbers of activated clusters was uncompromised in single individuals in both fMRI experiments. In the SMC, the multi-subject analysis revealed an increase of 66% of the maximal t-value whereby the number of activated clusters was increased by a factor of 3.3 when the matrix size (PI-factor) was increased from 96×96 (R=2) to 192×192 (R=4). In the NAcc, the number of activated clusters increased from 5 to 7 whereby the maximal t-value remained unaffected when the matrix size (PI-factor) was increased from 96×96 (R=2) to 160×160 (R=3). Using the proposed high-resolution EPI protocol, spatial blurring was clearly reduced. Further, BOLD sensitivity was clearly improved in multi-subject analyses and remained unaffected in single individuals compared to using the standard protocols. Conventionally used matrix sizes (PI-factors) might be non-optimal for some applications sacrificing BOLD spatial specificity. We recommend using the proposed high-resolution protocols applicable in detecting robust BOLD activation in fMRI. | ||
| 650 | 4 | |a fMRI | |
| 650 | 4 | |a Motivation | |
| 650 | 4 | |a Nucleus accumbens | |
| 650 | 4 | |a Parallel imaging | |
| 650 | 4 | |a Somatosensori motor cortex | |
| 650 | 4 | |a Spatial specificity | |
| 700 | 1 | |a Zapp, Jascha |e VerfasserIn |0 (DE-588)1060564955 |0 (DE-627)800322738 |0 (DE-576)290208920 |4 aut | |
| 700 | 1 | |a Schad, Lothar R. |d 1956- |e VerfasserIn |0 (DE-588)1028817630 |0 (DE-627)731640241 |0 (DE-576)376271221 |4 aut | |
| 700 | 1 | |a Nees, Frauke |e VerfasserIn |0 (DE-588)140286527 |0 (DE-627)703627244 |0 (DE-576)325389764 |4 aut | |
| 700 | 1 | |a Hill, Holger |e VerfasserIn |0 (DE-588)122577330X |0 (DE-627)1745699473 |4 aut | |
| 700 | 1 | |a Hermann, Derik |d 1972- |e VerfasserIn |0 (DE-588)121855139 |0 (DE-627)705679047 |0 (DE-576)292920490 |4 aut | |
| 700 | 1 | |a Mann, Karl |d 1948- |e VerfasserIn |0 (DE-588)120426455 |0 (DE-627)080667872 |0 (DE-576)187088012 |4 aut | |
| 700 | 1 | |a Vollstädt-Klein, Sabine |d 1973- |e VerfasserIn |0 (DE-588)128572744 |0 (DE-627)376206330 |0 (DE-576)188335935 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of neuroscience methods |d Amsterdam [u.a.] : Elsevier Science, 1979 |g 239(2015), Seite 170-182 |h Online-Ressource |w (DE-627)306659786 |w (DE-600)1500499-5 |w (DE-576)081986416 |x 1872-678X |7 nnas |a Optimized protocol for high resolution functional magnetic resonance imaging at 3T using single-shot echo planar imaging |
| 773 | 1 | 8 | |g volume:239 |g year:2015 |g pages:170-182 |g extent:13 |a Optimized protocol for high resolution functional magnetic resonance imaging at 3T using single-shot echo planar imaging |
| 856 | 4 | 0 | |u http://dx.doi.org/10.1016/j.jneumeth.2014.10.014 |x Verlag |x Resolving-System |3 Volltext |
| 856 | 4 | 0 | |u http://www.sciencedirect.com/science/article/pii/S0165027014003811 |x Verlag |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20170706 | ||
| 993 | |a Article | ||
| 994 | |a 2015 | ||
| 998 | |g 128572744 |a Vollstädt-Klein, Sabine |m 128572744:Vollstädt-Klein, Sabine |d 60000 |e 60000PV128572744 |k 0/60000/ |p 8 |y j | ||
| 998 | |g 120426455 |a Mann, Karl |m 120426455:Mann, Karl |d 60000 |e 60000PM120426455 |k 0/60000/ |p 7 | ||
| 998 | |g 121855139 |a Hermann, Derik |m 121855139:Hermann, Derik |d 60000 |e 60000PH121855139 |k 0/60000/ |p 6 | ||
| 998 | |g 1028817630 |a Schad, Lothar R. |m 1028817630:Schad, Lothar R. |p 3 | ||
| 998 | |g 1060564955 |a Zapp, Jascha |m 1060564955:Zapp, Jascha |p 2 | ||
| 998 | |g 103361016X |a Domsch, Sebastian |m 103361016X:Domsch, Sebastian |p 1 |x j | ||
| 999 | |a KXP-PPN1560532327 |e 2973254957 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"person":[{"role":"aut","family":"Domsch","given":"Sebastian","roleDisplay":"VerfasserIn","display":"Domsch, Sebastian"},{"family":"Zapp","display":"Zapp, Jascha","roleDisplay":"VerfasserIn","given":"Jascha","role":"aut"},{"role":"aut","family":"Schad","given":"Lothar R.","roleDisplay":"VerfasserIn","display":"Schad, Lothar R."},{"role":"aut","roleDisplay":"VerfasserIn","display":"Nees, Frauke","given":"Frauke","family":"Nees"},{"role":"aut","family":"Hill","roleDisplay":"VerfasserIn","display":"Hill, Holger","given":"Holger"},{"role":"aut","roleDisplay":"VerfasserIn","given":"Derik","display":"Hermann, Derik","family":"Hermann"},{"role":"aut","family":"Mann","roleDisplay":"VerfasserIn","given":"Karl","display":"Mann, Karl"},{"role":"aut","family":"Vollstädt-Klein","roleDisplay":"VerfasserIn","display":"Vollstädt-Klein, Sabine","given":"Sabine"}],"title":[{"title_sort":"Optimized protocol for high resolution functional magnetic resonance imaging at 3T using single-shot echo planar imaging","title":"Optimized protocol for high resolution functional magnetic resonance imaging at 3T using single-shot echo planar imaging"}],"id":{"eki":["1560532327"],"doi":["10.1016/j.jneumeth.2014.10.014"]},"recId":"1560532327","name":{"displayForm":["Sebastian Domsch, Jascha Zapp, Lothar R. Schad, Frauke Nees, Holger Hill, Derik Hermann, Karl Mann, Sabine Vollstädt-Klein"]},"note":["Gesehen am 06.07.2017"],"physDesc":[{"extent":"13 S."}],"relHost":[{"pubHistory":["1.1979 -"],"origin":[{"dateIssuedKey":"1979","dateIssuedDisp":"1979-","publisherPlace":"Amsterdam [u.a.]","publisher":"Elsevier Science"}],"recId":"306659786","id":{"eki":["306659786"],"zdb":["1500499-5"],"issn":["1872-678X"]},"title":[{"title":"Journal of neuroscience methods","title_sort":"Journal of neuroscience methods"}],"disp":"Optimized protocol for high resolution functional magnetic resonance imaging at 3T using single-shot echo planar imagingJournal of neuroscience methods","language":["eng"],"note":["Gesehen am 30.03.11"],"part":{"year":"2015","pages":"170-182","volume":"239","text":"239(2015), Seite 170-182","extent":"13"},"physDesc":[{"extent":"Online-Ressource"}],"type":{"media":"Online-Ressource","bibl":"periodical"}}],"language":["eng"],"origin":[{"dateIssuedKey":"2015","dateIssuedDisp":"15 January 2015"}]} | ||
| SRT | |a DOMSCHSEBAOPTIMIZEDP1520 | ||