Low material budget floating strip Micromegas for ion transmission radiography

Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7MHz/cm2 with 100μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encou...

Full description

Saved in:
Bibliographic Details
Main Authors: Bortfeldt, Jonathan (Author) , Magallanes Herńandez, Lorena (Author) , Parodi, Katia (Author)
Format: Article (Journal)
Language:English
Published: 2 May 2016
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2017, Volume: 845, Pages: 210-214
ISSN:1872-9576
DOI:10.1016/j.nima.2016.05.003
Online Access:Verlag, Volltext: http://dx.doi.org/10.1016/j.nima.2016.05.003
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0168900216303606
Get full text
Author Notes:J. Bortfeldt, O. Biebel, B. Flierl, R. Hertenberger, F. Klitzner, Ph. Lösel, L. Magallanes, R. Müller, K. Parodi, T. Schlüter, B. Voss, A. Zibell
Description
Summary:Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7MHz/cm2 with 100μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X0. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF4 gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.
Item Description:Gesehen am 26.04.2018
Physical Description:Online Resource
ISSN:1872-9576
DOI:10.1016/j.nima.2016.05.003