Electromagnetic bone segment tracking to control femoral derotation osteotomy: a saw bone study

ABSTRACT Correction of rotational gait abnormalities is common practice in pediatric orthopaedics such as in children with cerebral palsy. Femoral derotation osteotomy is established as a standard treatment, however, different authors reported substantial variability in outcomes following surgery wi...

Full description

Saved in:
Bibliographic Details
Main Authors: Geisbüsch, Andreas (Author) , Auer, Christoph (Author) , Dickhaus, Hartmut (Author) , Thielen, Mirjam (Author) , Dreher, Thomas (Author)
Format: Article (Journal)
Language:English
Published: 2017
In: Journal of orthopaedic research
Year: 2017, Volume: 35, Issue: 5, Pages: 1106-1112
ISSN:1554-527X
DOI:10.1002/jor.23348
Online Access:Verlag, Volltext: http://dx.doi.org/10.1002/jor.23348
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jor.23348
Get full text
Author Notes:Andreas Geisbüsch, Christoph Auer, Hartmut Dickhaus, Mirjam Niklasch, Thomas Dreher
Description
Summary:ABSTRACT Correction of rotational gait abnormalities is common practice in pediatric orthopaedics such as in children with cerebral palsy. Femoral derotation osteotomy is established as a standard treatment, however, different authors reported substantial variability in outcomes following surgery with patients showing over? or under?correction. Only 60% of the applied correction is observed postoperatively, which strongly suggests intraoperative measurement error or loss of correction during surgery. This study was conducted to verify the impact of error sources in the derotation procedure and assess the utility of a newly developed, instrumented measurement system based on electromagnetic tracking aiming to improve the accuracy of rotational correction. A supracondylar derotation osteotomy was performed in 21 artificial femur sawbones and the amount of derotation was quantified during the procedure by the tracking system and by nine raters using a conventional goniometer. Accuracy of both measurement devices was determined by repeated computer tomography scans. Average derotation measured by the tracking system differed by 0.1°?±?1.6° from the defined reference measurement . In contrast, a high inter?rater variability was found in goniometric measurements (range: 10.8°?±?6.9°, mean interquartile distance: 6.6°). During fixation of the osteosynthesis, the tracking system reliably detected unintentional manipulation of the correction angle with a mean absolute change of 4.0°?±?3.2°. Our findings show that conventional control of femoral derotation is subject to relevant observer bias whereas instrumental tracking yields accuracy better than ±2°. The tracking system is a step towards more reliable and safe implementation of femoral correction, promising substantial improvements of patient safety in the future. ? 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1106?1112, 2017.
Item Description:Published online: 21 June 2016