The importance of pulsed lavage on interface temperature and ligament tension force in cemented unicompartmental knee arthroplasty

Background Mechanical loosening is the most common cause of revision in unicompartmental knee arthroplasty. We determined the effect of bone lavage on tibial cement penetration and interface temperature with controlled ligament tension forces. We presumed pulsed lavage would allow increased cement p...

Full description

Saved in:
Bibliographic Details
Main Authors: Clarius, Michael (Author) , Seeger, Jörn Bengt (Author) , Jäger, Sebastian (Author) , Bitsch, Rudi G. (Author)
Format: Article (Journal)
Language:English
Published: 2012
In: Clinical biomechanics
Year: 2012, Volume: 27, Issue: 4, Pages: 372-376
ISSN:1879-1271
DOI:10.1016/j.clinbiomech.2011.10.006
Online Access:Verlag, Volltext: http://dx.doi.org/10.1016/j.clinbiomech.2011.10.006
Verlag, Volltext: http://www.sciencedirect.com/science/article/pii/S0268003311002646
Get full text
Author Notes:M. Clarius, J.B. Seeger, S. Jaeger, G. Mohr, R.G. Bitsch
Description
Summary:Background Mechanical loosening is the most common cause of revision in unicompartmental knee arthroplasty. We determined the effect of bone lavage on tibial cement penetration and interface temperature with controlled ligament tension forces. We presumed pulsed lavage would allow increased cement penetration compared with syringe lavage. Methods Cemented unicompartmental knee arthroplasty was performed in 12 pairs of fresh-frozen knees. Lavage was performed using pulsed lavage on one side (A) and syringe lavage on the other (B). Cement penetration pressure, interface temperature, and ligament tension forces were continuously monitored during the operation. Screened radiographs were taken and cement penetration under the tibial plateau was measured. Findings The pulsed lavage group showed a mean cement penetration area of 187.24 (SD 36.37) mm², whereas 144.29 (SD 35.74) mm2 was measured in the group with syringe lavage. Cement penetration pressure was 13.29 (SD 8.69) kPa in Group A and 20.21 (SD 7.78) kPa in Group B. Maximum interface temperatures of 46.99°C were observed in Group A and 45.02°C in Group B. Interpretation Our data showed pulsed lavage cleansing of the cancellous tibial bone substantially improved cement penetration compared with syringe lavage without reaching the temperature threshold for bone necrosis. We recommend the routine use of pulsed lavage to improve long-term fixation.
Item Description:Available online 1 November 2011
Gesehen am 06.08.2018
Physical Description:Online Resource
ISSN:1879-1271
DOI:10.1016/j.clinbiomech.2011.10.006