Magnetic tracking in the operation room using the da Vinci® telemanipulator is feasible

In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. I...

Full description

Saved in:
Bibliographic Details
Main Authors: Kenngott, Hannes Götz (Author) , Nickel, Felix (Author) , Fischer, Lars (Author) , Gehrig, Tobias (Author) , Meinzer, Hans-Peter (Author) , Müller, Beat P. (Author)
Format: Article (Journal)
Language:English
Published: 2013
In: Journal of robotic surgery
Year: 2013, Volume: 7, Issue: 1, Pages: 59-64
ISSN:1863-2491
DOI:10.1007/s11701-012-0347-2
Online Access:Verlag, Volltext: http://dx.doi.org/10.1007/s11701-012-0347-2
Verlag, Volltext: https://link.springer.com/article/10.1007/s11701-012-0347-2
Get full text
Author Notes:H.G. Kenngott, I. Wegner, J. Neuhaus, F. Nickel, L. Fischer, T. Gehrig, H.P. Meinzer, B.P. Müller-Stich
Description
Summary:In recent years, robotic assistance for surgical procedures has grown on a worldwide scale, particularly for use in more complex operations. Such operations usually require meticulous handling of tissue, involve a narrow working space and limit the surgeon’s sense of orientation in the human body. Improvement in both tissue handling and working within a narrow working space might be achieved through the use of robotic assistance. Soft tissue navigation might improve orientation by visualizing important target and risk structures intraoperatively, thereby possibly improving patient outcome. Prerequisites for navigation are its integration into the surgical workflow and accurate localization of both the instruments and patient. Magnetic tracking allows for good integration but is susceptible to distortion through metal or electro-magnetic interference, which may be caused by the operation table or a robotic system. We have investigated whether magnetic tracking can be used in combination with the da Vinci® (DV) telemanipulator in terms of stability and precision. We used a common magnetic tracking system (Aurora®, NDI Inc.) with the DV in a typical operation setup. Magnetic field distortion was evaluated using a measuring facility, with the following reference system: without any metal (R), operation table alone (T), DV in standby (D) and DV in motion (Dm). The maximum error of the entire tracking volume for R, T, D and Dm was 9.9, 32.8, 37.9 and 37.2 mm, respectively. Limiting the tracking volume to 190 mm (from cranial to caudal) resulted in a maximum error of 4.0, 8.3, 8.5 and 8.9 mm, respectively. When used in the operation room, magnetic tracking shows high errors, mainly due to the operation table. The target area should be limited to increase accuracy, which is possible for most surgical applications. The use of the da Vinci® telemanipulator only slightly aggravates the distortion and can thus be used in combination with magnetic tracking systems.
Item Description:First online: 24 March 2012
Gesehen am 08.08.2018
Physical Description:Online Resource
ISSN:1863-2491