3D cephalometric analysis using Magnetic Resonance Imaging: validation of accuracy and reproducibility

The aim of this study was to validate geometric accuracy and in vivo reproducibility of landmark-based cephalometric measurements using high-resolution 3D Magnetic Resonance Imaging (MRI) at 3 Tesla. For accuracy validation, 96 angular and 96 linear measurements were taken on a phantom in 3 differen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Jürchott, Alexander (VerfasserIn) , Saleem, Muhammad Abdullah (VerfasserIn) , Hilgenfeld, Tim (VerfasserIn) , Freudlsperger, Christian (VerfasserIn) , Zingler, Sebastian (VerfasserIn) , Lux, Christopher J. (VerfasserIn) , Bendszus, Martin (VerfasserIn) , Heiland, Sabine (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 29 August 2018
In: Scientific reports
Year: 2018, Jahrgang: 8
ISSN:2045-2322
DOI:10.1038/s41598-018-31384-8
Online-Zugang:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1038/s41598-018-31384-8
Verlag, kostenfrei, Volltext: https://www.nature.com/articles/s41598-018-31384-8
Volltext
Verfasserangaben:Alexander Juerchott, Muhammad Abdullah Saleem, Tim Hilgenfeld, Christian Freudlsperger, Sebastian Zingler, Christopher J. Lux, Martin Bendszus & Sabine Heiland

MARC

LEADER 00000caa a2200000 c 4500
001 1581138407
003 DE-627
005 20240316100525.0
007 cr uuu---uuuuu
008 180920s2018 xx |||||o 00| ||eng c
024 7 |a 10.1038/s41598-018-31384-8  |2 doi 
035 |a (DE-627)1581138407 
035 |a (DE-576)511138407 
035 |a (DE-599)BSZ511138407 
035 |a (OCoLC)1264006729 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Jürchott, Alexander  |e VerfasserIn  |0 (DE-588)1167429230  |0 (DE-627)1031103090  |0 (DE-576)511136137  |4 aut 
245 1 0 |a 3D cephalometric analysis using Magnetic Resonance Imaging  |b validation of accuracy and reproducibility  |c Alexander Juerchott, Muhammad Abdullah Saleem, Tim Hilgenfeld, Christian Freudlsperger, Sebastian Zingler, Christopher J. Lux, Martin Bendszus & Sabine Heiland 
246 3 0 |a ThreeD 
264 1 |c 29 August 2018 
300 |a 11 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 20.09.2018 
520 |a The aim of this study was to validate geometric accuracy and in vivo reproducibility of landmark-based cephalometric measurements using high-resolution 3D Magnetic Resonance Imaging (MRI) at 3 Tesla. For accuracy validation, 96 angular and 96 linear measurements were taken on a phantom in 3 different positions. In vivo MRI scans were performed on 3 volunteers in five head positions. For each in vivo scan, 27 landmarks were determined from which 19 angles and 26 distances were calculated. Statistical analysis was performed using Bland-Altman analysis, the two one-sided tests procedure and repeated measures one-way analysis of variance. In comparison to ground truth, all MRI-based phantom measurements showed statistical equivalence (p  0.05). Ranges between maximum and minimum in vivo values were consistently smaller than 2° and 2 mm, respectively (average ranges: 0.88°/0.87 mm). In conclusion, this study demonstrates that accurate and reproducible 3D cephalometric analysis can be performed without exposure to ionizing radiation using MRI. 
700 1 |a Saleem, Muhammad Abdullah  |e VerfasserIn  |0 (DE-588)1167429923  |0 (DE-627)1031103481  |0 (DE-576)511136587  |4 aut 
700 1 |a Hilgenfeld, Tim  |d 1986-  |e VerfasserIn  |0 (DE-588)1106261917  |0 (DE-627)862954398  |0 (DE-576)473950316  |4 aut 
700 1 |a Freudlsperger, Christian  |d 1977-  |e VerfasserIn  |0 (DE-588)130275913  |0 (DE-627)589450751  |0 (DE-576)301504105  |4 aut 
700 1 |a Zingler, Sebastian  |d 1976-  |e VerfasserIn  |0 (DE-588)143211390  |0 (DE-627)704421933  |0 (DE-576)335662706  |4 aut 
700 1 |a Lux, Christopher J.  |d 1969-  |e VerfasserIn  |0 (DE-588)121600114  |0 (DE-627)081413815  |0 (DE-576)292792549  |4 aut 
700 1 |a Bendszus, Martin  |e VerfasserIn  |0 (DE-588)1032676426  |0 (DE-627)738634131  |0 (DE-576)175567697  |4 aut 
700 1 |a Heiland, Sabine  |e VerfasserIn  |0 (DE-588)106732626X  |0 (DE-627)818624450  |0 (DE-576)426561368  |4 aut 
773 0 8 |i Enthalten in  |t Scientific reports  |d [London] : Springer Nature, 2011  |g 8(2018) Artikel-Nummer 13029, 11 Seiten  |h Online-Ressource  |w (DE-627)663366712  |w (DE-600)2615211-3  |w (DE-576)346641179  |x 2045-2322  |7 nnas  |a 3D cephalometric analysis using Magnetic Resonance Imaging validation of accuracy and reproducibility 
773 1 8 |g volume:8  |g year:2018  |g extent:11  |a 3D cephalometric analysis using Magnetic Resonance Imaging validation of accuracy and reproducibility 
856 4 0 |u http://dx.doi.org/10.1038/s41598-018-31384-8  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://www.nature.com/articles/s41598-018-31384-8  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20180920 
993 |a Article 
994 |a 2018 
998 |g 106732626X  |a Heiland, Sabine  |m 106732626X:Heiland, Sabine  |d 910000  |d 911100  |e 910000PH106732626X  |e 911100PH106732626X  |k 0/910000/  |k 1/910000/911100/  |p 8  |y j 
998 |g 1032676426  |a Bendszus, Martin  |m 1032676426:Bendszus, Martin  |d 910000  |d 911100  |e 910000PB1032676426  |e 911100PB1032676426  |k 0/910000/  |k 1/910000/911100/  |p 7 
998 |g 121600114  |a Lux, Christopher J.  |m 121600114:Lux, Christopher J.  |d 910000  |d 910800  |e 910000PL121600114  |e 910800PL121600114  |k 0/910000/  |k 1/910000/910800/  |p 6 
998 |g 143211390  |a Zingler, Sebastian  |m 143211390:Zingler, Sebastian  |d 910000  |d 910800  |e 910000PZ143211390  |e 910800PZ143211390  |k 0/910000/  |k 1/910000/910800/  |p 5 
998 |g 130275913  |a Freudlsperger, Christian  |m 130275913:Freudlsperger, Christian  |d 910000  |d 910800  |e 910000PF130275913  |e 910800PF130275913  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 1106261917  |a Hilgenfeld, Tim  |m 1106261917:Hilgenfeld, Tim  |d 910000  |d 911100  |e 910000PH1106261917  |e 911100PH1106261917  |k 0/910000/  |k 1/910000/911100/  |p 3 
998 |g 1167429923  |a Saleem, Muhammad Abdullah  |m 1167429923:Saleem, Muhammad Abdullah  |d 910000  |d 911100  |e 910000PS1167429923  |e 911100PS1167429923  |k 0/910000/  |k 1/910000/911100/  |p 2 
998 |g 1167429230  |a Jürchott, Alexander  |m 1167429230:Jürchott, Alexander  |d 910000  |d 911100  |e 910000PJ1167429230  |e 911100PJ1167429230  |k 0/910000/  |k 1/910000/911100/  |p 1  |x j 
999 |a KXP-PPN1581138407  |e 3025895713 
BIB |a Y 
SER |a journal 
JSO |a {"name":{"displayForm":["Alexander Juerchott, Muhammad Abdullah Saleem, Tim Hilgenfeld, Christian Freudlsperger, Sebastian Zingler, Christopher J. Lux, Martin Bendszus & Sabine Heiland"]},"physDesc":[{"extent":"11 S."}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"relHost":[{"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"663366712","language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"part":{"extent":"11","year":"2018","volume":"8","text":"8(2018) Artikel-Nummer 13029, 11 Seiten"},"id":{"eki":["663366712"],"issn":["2045-2322"],"zdb":["2615211-3"]},"pubHistory":["1, article number 1 (2011)-"],"origin":[{"publisher":"Springer Nature ; Nature Publishing Group","dateIssuedDisp":"2011-","publisherPlace":"[London] ; London","dateIssuedKey":"2011"}],"title":[{"title_sort":"Scientific reports","title":"Scientific reports"}],"note":["Gesehen am 12.07.24"],"disp":"3D cephalometric analysis using Magnetic Resonance Imaging validation of accuracy and reproducibilityScientific reports"}],"language":["eng"],"recId":"1581138407","note":["Gesehen am 20.09.2018"],"person":[{"role":"aut","given":"Alexander","family":"Jürchott","display":"Jürchott, Alexander"},{"display":"Saleem, Muhammad Abdullah","family":"Saleem","role":"aut","given":"Muhammad Abdullah"},{"display":"Hilgenfeld, Tim","given":"Tim","role":"aut","family":"Hilgenfeld"},{"role":"aut","given":"Christian","family":"Freudlsperger","display":"Freudlsperger, Christian"},{"given":"Sebastian","role":"aut","family":"Zingler","display":"Zingler, Sebastian"},{"display":"Lux, Christopher J.","role":"aut","given":"Christopher J.","family":"Lux"},{"display":"Bendszus, Martin","family":"Bendszus","role":"aut","given":"Martin"},{"family":"Heiland","role":"aut","given":"Sabine","display":"Heiland, Sabine"}],"title":[{"title_sort":"3D cephalometric analysis using Magnetic Resonance Imaging","title":"3D cephalometric analysis using Magnetic Resonance Imaging","subtitle":"validation of accuracy and reproducibility"}],"origin":[{"dateIssuedDisp":"29 August 2018","dateIssuedKey":"2018"}],"id":{"doi":["10.1038/s41598-018-31384-8"],"eki":["1581138407"]}} 
SRT |a JUERCHOTTA3DCEPHALOM2920