Adaptive-illumination STED nanoscopy

The concepts called STED/RESOLFT superresolve features by a light-driven transfer of closely packed molecules between two different states, typically a nonfluorescent “off” state and a fluorescent “on” state at well-defined coordinates on subdiffraction scales. For this, the applied light intensity...

Full description

Saved in:
Bibliographic Details
Main Authors: Heine, Jörn (Author) , Hell, Stefan (Author)
Format: Article (Journal)
Language:English
Published: 28 August 2017
In: Proceedings of the National Academy of Sciences of the United States of America
Year: 2017, Volume: 114, Issue: 37, Pages: 9797-9802
ISSN:1091-6490
DOI:10.1073/pnas.1708304114
Online Access:Verlag, Volltext: http://dx.doi.org/10.1073/pnas.1708304114
Verlag, Volltext: http://www.pnas.org/content/114/37/9797
Get full text
Author Notes:Jörn Heine, Matthias Reuss, Benjamin Harke, Elisa D’Este, Steffen J. Sahl, and Stefan W. Hell
Description
Summary:The concepts called STED/RESOLFT superresolve features by a light-driven transfer of closely packed molecules between two different states, typically a nonfluorescent “off” state and a fluorescent “on” state at well-defined coordinates on subdiffraction scales. For this, the applied light intensity must be sufficient to guarantee the state difference for molecules spaced at the resolution sought. Relatively high intensities have therefore been applied throughout the imaging to obtain the highest resolutions. At regions where features are far enough apart that molecules could be separated with lower intensity, the excess intensity just adds to photobleaching. Here, we introduce DyMIN (standing for Dynamic Intensity Minimum) scanning, generalizing and expanding on earlier concepts of RESCue and MINFIELD to reduce sample exposure. The principle of DyMIN is that it only uses as much on/off-switching light as needed to image at the desired resolution. Fluorescence can be recorded at those positions where fluorophores are found within a subresolution neighborhood. By tuning the intensity (and thus resolution) during the acquisition of each pixel/voxel, we match the size of this neighborhood to the structures being imaged. DyMIN is shown to lower the dose of STED light on the scanned region up to ∼20-fold under common biological imaging conditions, and >100-fold for sparser 2D and 3D samples. The bleaching reduction can be converted into accordingly brighter images at <30-nm resolution.
Item Description:Gesehen am 24.10.2018
Physical Description:Online Resource
ISSN:1091-6490
DOI:10.1073/pnas.1708304114