Solid immersion facilitates fluorescence microscopy with nanometer resolution and sub-Ångström emitter localization

Exploring the maximum spatial resolution achievable in far-field optical imaging, we show that applying solid immersion lenses (SIL) in stimulated emission depletion (STED) microscopy addresses single spins with a resolution down to 2.4 ± 0.3 nm and with a localization precision of 0.09 nm.

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Wildanger, Dominik (VerfasserIn) , Hell, Stefan (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: November 20, 2012
In: Advanced materials
Year: 2012, Jahrgang: 24, Heft: 44, Pages: OP309-OP313
ISSN:1521-4095
DOI:10.1002/adma.201203033
Online-Zugang:Verlag, kostenfrei, Volltext: http://dx.doi.org/10.1002/adma.201203033
Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/adma.201203033
Volltext
Verfasserangaben:Dominik Wildanger, Brian R. Patton, Heiko Schill, Luca Marseglia, J.P. Hadden, Sebastian Knauer, Andreas Schönle, John G. Rarity, Jeremy L. O'Brien, Stefan W. Hell, and Jason M. Smith

MARC

LEADER 00000caa a2200000 c 4500
001 1582587434
003 DE-627
005 20220815045632.0
007 cr uuu---uuuuu
008 181105s2012 xx |||||o 00| ||eng c
024 7 |a 10.1002/adma.201203033  |2 doi 
035 |a (DE-627)1582587434 
035 |a (DE-576)512587434 
035 |a (DE-599)BSZ512587434 
035 |a (OCoLC)1341022323 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 29  |2 sdnb 
100 1 |a Wildanger, Dominik  |e VerfasserIn  |0 (DE-588)1170640303  |0 (DE-627)1039833845  |0 (DE-576)51258737X  |4 aut 
245 1 0 |a Solid immersion facilitates fluorescence microscopy with nanometer resolution and sub-Ångström emitter localization  |c Dominik Wildanger, Brian R. Patton, Heiko Schill, Luca Marseglia, J.P. Hadden, Sebastian Knauer, Andreas Schönle, John G. Rarity, Jeremy L. O'Brien, Stefan W. Hell, and Jason M. Smith 
264 1 |c November 20, 2012 
300 |a 5 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 05.11.2018 
520 |a Exploring the maximum spatial resolution achievable in far-field optical imaging, we show that applying solid immersion lenses (SIL) in stimulated emission depletion (STED) microscopy addresses single spins with a resolution down to 2.4 ± 0.3 nm and with a localization precision of 0.09 nm. 
650 4 |a color centers 
650 4 |a nanoscopy 
650 4 |a ODMR 
650 4 |a solid immersion lens 
650 4 |a STED 
700 1 |a Hell, Stefan  |d 1962-  |e VerfasserIn  |0 (DE-588)139815716  |0 (DE-627)613785681  |0 (DE-576)313195889  |4 aut 
773 0 8 |i Enthalten in  |t Advanced materials  |d Weinheim : Wiley-VCH, 1989  |g 24(2012), 44, Seite OP309-OP313  |h Online-Ressource  |w (DE-627)269533958  |w (DE-600)1474949-X  |w (DE-576)077884531  |x 1521-4095  |7 nnas  |a Solid immersion facilitates fluorescence microscopy with nanometer resolution and sub-Ångström emitter localization 
773 1 8 |g volume:24  |g year:2012  |g number:44  |g pages:OP309-OP313  |g extent:5  |a Solid immersion facilitates fluorescence microscopy with nanometer resolution and sub-Ångström emitter localization 
856 4 0 |u http://dx.doi.org/10.1002/adma.201203033  |x Verlag  |x Resolving-System  |z kostenfrei  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1002/adma.201203033  |x Verlag  |z kostenfrei  |3 Volltext 
951 |a AR 
992 |a 20181105 
993 |a Article 
994 |a 2012 
998 |g 139815716  |a Hell, Stefan  |m 139815716:Hell, Stefan  |d 130000  |d 130001  |d 700000  |d 718000  |e 130000PH139815716  |e 130001PH139815716  |e 700000PH139815716  |e 718000PH139815716  |k 0/130000/  |k 1/130000/130001/  |k 0/700000/  |k 1/700000/718000/  |p 10 
999 |a KXP-PPN1582587434  |e 3030456080 
BIB |a Y 
SER |a journal 
JSO |a {"relHost":[{"physDesc":[{"extent":"Online-Ressource"}],"id":{"zdb":["1474949-X"],"eki":["269533958"],"doi":["10.1002/(ISSN)1521-4095"],"issn":["1521-4095"]},"origin":[{"dateIssuedKey":"1989","publisher":"Wiley-VCH","dateIssuedDisp":"1989-","publisherPlace":"Weinheim"}],"part":{"year":"2012","pages":"OP309-OP313","issue":"44","text":"24(2012), 44, Seite OP309-OP313","volume":"24","extent":"5"},"pubHistory":["1.1989 -"],"language":["eng"],"recId":"269533958","type":{"bibl":"periodical","media":"Online-Ressource"},"disp":"Solid immersion facilitates fluorescence microscopy with nanometer resolution and sub-Ångström emitter localizationAdvanced materials","note":["Gesehen am 10.10.05"],"title":[{"title":"Advanced materials","title_sort":"Advanced materials"}]}],"physDesc":[{"extent":"5 S."}],"id":{"doi":["10.1002/adma.201203033"],"eki":["1582587434"]},"origin":[{"dateIssuedDisp":"November 20, 2012","dateIssuedKey":"2012"}],"name":{"displayForm":["Dominik Wildanger, Brian R. Patton, Heiko Schill, Luca Marseglia, J.P. Hadden, Sebastian Knauer, Andreas Schönle, John G. Rarity, Jeremy L. O'Brien, Stefan W. Hell, and Jason M. Smith"]},"language":["eng"],"recId":"1582587434","note":["Gesehen am 05.11.2018"],"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title_sort":"Solid immersion facilitates fluorescence microscopy with nanometer resolution and sub-Ångström emitter localization","title":"Solid immersion facilitates fluorescence microscopy with nanometer resolution and sub-Ångström emitter localization"}],"person":[{"role":"aut","roleDisplay":"VerfasserIn","display":"Wildanger, Dominik","given":"Dominik","family":"Wildanger"},{"role":"aut","display":"Hell, Stefan","roleDisplay":"VerfasserIn","given":"Stefan","family":"Hell"}]} 
SRT |a WILDANGERDSOLIDIMMER2020