23Na triple-quantum signal of in vitro human liver cells, liposomes, and nanoparticles: Cell viability assessment vs. separation of intra- and extracellular signal

Background Triple-quantum (TQ) filtered sequences have become more popular in sodium MR due to the increased usage of scanners with field strengths exceeding 3T. Disagreement as to whether TQ signal can provide separation of intra- and extracellular compartments persists. Purpose To provide insight...

Full description

Saved in:
Bibliographic Details
Main Authors: Hösl, Michaela (Author) , Kleimaier, Dennis (Author) , Hu, Ruomin (Author) , Malzacher, Matthias (Author) , Nies, Cordula (Author) , Gottwald, Eric (Author) , Schad, Lothar R. (Author)
Format: Article (Journal)
Language:English
Published: 25 January 2019
In: Journal of magnetic resonance imaging
Year: 2019, Volume: 50, Issue: 2, Pages: 435-444
ISSN:1522-2586
DOI:10.1002/jmri.26666
Online Access:Verlag, Volltext: https://doi.org/10.1002/jmri.26666
Verlag, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jmri.26666
Get full text
Author Notes:Michaela A.U. Hoesl, MS, Dennis Kleimaier, MS, Ruomin Hu, MS, Matthias Malzacher, MS, Cordula Nies, Eric Gottwald, PhD, and Lothar R. Schad, PhD
Description
Summary:Background Triple-quantum (TQ) filtered sequences have become more popular in sodium MR due to the increased usage of scanners with field strengths exceeding 3T. Disagreement as to whether TQ signal can provide separation of intra- and extracellular compartments persists. Purpose To provide insight into TQ signal behavior on a cellular level. Study Type Prospective. Phantom/Specimen Cell-phantoms in the form of liposomes, encapsulated 0 mM, 145 mM, 154 mM Na+ in a double-lipid membrane similar to cells. Poly(lactic-co-glycolic acid) nanoparticles encapsulated 154 mM Na+ within a single-layer membrane structure. Two microcavity chips with each 6 × 106 human HEP G2 liver cells were measured in an MR-compatible bioreactor. Field Strength/Sequence Spectroscopic TQ sequence with time proportional phase-increments at 9.4T. Assessment The TQ signal of viable, dead cells, and cell-phantoms was assessed by a fit in the time domain and by the amplitude in the frequency domain. Statistical Tests The noise variance (σ) was evaluated to express the deviation of the measured TQ signal amplitude from noise. Results TQ signal >20σ was found for liposomes encapsulating sodium ions. Liposomal encapsulation of 0 mM Na+ and 154 mM Na+ encapsulation in the nanoparticles resulted in <2σ TQ signal. Cells under normal perfusion resulted in >9σ TQ signal. Compared with TQ signal under normal perfusion, a 56% lower TQ signal of was observed (25σ) during perfusion stop. TQ signal returned to 92% of the initial signal after reperfusion. Data Conclusion Our measurements indicate that TQ signal in liposomes was observed due to the trapping of ions within the double-lipid membrane rather than from the intraliposomal space. Transfer to the cell results suggests that TQ signal was observed from motion restriction equivalent to trapping. Level of Evidence: 1 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2019;50:435-444.
Item Description:Im Titel ist die Zahl "23" hochgestellt
Gesehen am 05.12.2019
Physical Description:Online Resource
ISSN:1522-2586
DOI:10.1002/jmri.26666