The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens

Purpose - To study the effect of glistenings on the optical quality of a hydrophobic acrylic intraocular lens (IOL). - Setting - David J. Apple Laboratory, Heidelberg, Germany. - Design - An in vitro laboratory study. - Methods - An accelerated ag...

Full description

Saved in:
Bibliographic Details
Main Authors: Weindler, Jan N. (Author) , Łabuz, Grzegorz (Author) , Yildirim, Timur Mert (Author) , Tandogan, Tamer (Author) , Khoramnia, Ramin (Author) , Auffarth, Gerd U. (Author)
Format: Article (Journal)
Language:English
Published: 2019
In: Journal of cataract and refractive surgery
Year: 2019, Volume: 45, Issue: 7, Pages: 1020-1025
ISSN:1873-4502
DOI:10.1016/j.jcrs.2019.01.025
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcrs.2019.01.025
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/FullText/2019/07000/The_impact_of_glistenings_on_the_optical_quality.21.aspx
Get full text
Author Notes:Jan N. Weindler, MD, Grzegorz Łabuz, PhD, Timur M. Yildirim, MD, Tamer Tandogan, MD, Ramin Khoramnia, MD, FEBO, Gerd U. Auffarth, MD, PhD
Description
Summary:Purpose - To study the effect of glistenings on the optical quality of a hydrophobic acrylic intraocular lens (IOL). - Setting - David J. Apple Laboratory, Heidelberg, Germany. - Design - An in vitro laboratory study. - Methods - An accelerated aging protocol was used to induce glistenings (microvacuoles) in 38 hydrophobic acrylic IOLs. The IOLs were warmed to 45°C and then cooled to 37°C. Image analysis of light-microcopy photographs determined the number and size of microvacuoles (MV). A classification was applied based on the glistening number per mm2: grade 0 (none), grade 1 (1-100), grade 2 (101-200), grade 3 (201-500) and grade 4 (more than 500). An optical bench was used to measure each IOL’s modulation transfer function (MTF) and Strehl ratio to evaluate the impact of glistenings on image quality. - Results - Glistenings were observed in all IOLs. The mean glistening numbers ± SD (MV/mm2) in grades 1 through 4 were 74 ± 12.7, 142 ± 22.2, 297 ± 76.2, and 1509 ± 311.9, respectively. The mean glistening sizes in grades 1 through 4 were 13.28 ± 3.85 μm, 15.88 ± 2.08 μm, 16.85 ± 3.23 μm, and 15.27 ± 2.25 μm, respectively. Statistical analysis showed that grades 1 through 3 did not change the optical quality; however, in grade 4, the MTF and the Strehl ratio were significantly affected. - Conclusion - A limited number of glistenings (<500 MV/mm2) had no effect on the image quality. Although statistically significant deteriorations in the MTF and the Strehl ratio were observed in grade 4, the effects found were small and are unlikely to affect the visual quality.
Item Description:Gesehen am 20.04.2020
Physical Description:Online Resource
ISSN:1873-4502
DOI:10.1016/j.jcrs.2019.01.025