The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens
Purpose - To study the effect of glistenings on the optical quality of a hydrophobic acrylic intraocular lens (IOL). - Setting - David J. Apple Laboratory, Heidelberg, Germany. - Design - An in vitro laboratory study. - Methods - An accelerated ag...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
2019
|
| In: |
Journal of cataract and refractive surgery
Year: 2019, Volume: 45, Issue: 7, Pages: 1020-1025 |
| ISSN: | 1873-4502 |
| DOI: | 10.1016/j.jcrs.2019.01.025 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcrs.2019.01.025 Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/jcrs/FullText/2019/07000/The_impact_of_glistenings_on_the_optical_quality.21.aspx |
| Author Notes: | Jan N. Weindler, MD, Grzegorz Łabuz, PhD, Timur M. Yildirim, MD, Tamer Tandogan, MD, Ramin Khoramnia, MD, FEBO, Gerd U. Auffarth, MD, PhD |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1695023226 | ||
| 003 | DE-627 | ||
| 005 | 20240405193220.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 200420s2019 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jcrs.2019.01.025 |2 doi | |
| 035 | |a (DE-627)1695023226 | ||
| 035 | |a (DE-599)KXP1695023226 | ||
| 035 | |a (OCoLC)1341315888 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Weindler, Jan N. |d 1992- |e VerfasserIn |0 (DE-588)120866543X |0 (DE-627)1695019644 |4 aut | |
| 245 | 1 | 4 | |a The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens |c Jan N. Weindler, MD, Grzegorz Łabuz, PhD, Timur M. Yildirim, MD, Tamer Tandogan, MD, Ramin Khoramnia, MD, FEBO, Gerd U. Auffarth, MD, PhD |
| 264 | 1 | |c 2019 | |
| 300 | |a 6 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 20.04.2020 | ||
| 520 | |a Purpose - To study the effect of glistenings on the optical quality of a hydrophobic acrylic intraocular lens (IOL). - Setting - David J. Apple Laboratory, Heidelberg, Germany. - Design - An in vitro laboratory study. - Methods - An accelerated aging protocol was used to induce glistenings (microvacuoles) in 38 hydrophobic acrylic IOLs. The IOLs were warmed to 45°C and then cooled to 37°C. Image analysis of light-microcopy photographs determined the number and size of microvacuoles (MV). A classification was applied based on the glistening number per mm2: grade 0 (none), grade 1 (1-100), grade 2 (101-200), grade 3 (201-500) and grade 4 (more than 500). An optical bench was used to measure each IOL’s modulation transfer function (MTF) and Strehl ratio to evaluate the impact of glistenings on image quality. - Results - Glistenings were observed in all IOLs. The mean glistening numbers ± SD (MV/mm2) in grades 1 through 4 were 74 ± 12.7, 142 ± 22.2, 297 ± 76.2, and 1509 ± 311.9, respectively. The mean glistening sizes in grades 1 through 4 were 13.28 ± 3.85 μm, 15.88 ± 2.08 μm, 16.85 ± 3.23 μm, and 15.27 ± 2.25 μm, respectively. Statistical analysis showed that grades 1 through 3 did not change the optical quality; however, in grade 4, the MTF and the Strehl ratio were significantly affected. - Conclusion - A limited number of glistenings (<500 MV/mm2) had no effect on the image quality. Although statistically significant deteriorations in the MTF and the Strehl ratio were observed in grade 4, the effects found were small and are unlikely to affect the visual quality. | ||
| 700 | 1 | |a Łabuz, Grzegorz |e VerfasserIn |0 (DE-588)1185406743 |0 (DE-627)1664595244 |4 aut | |
| 700 | 1 | |a Yildirim, Timur Mert |d 1990- |e VerfasserIn |0 (DE-588)112972557X |0 (DE-627)88437422X |0 (DE-576)486529894 |4 aut | |
| 700 | 1 | |a Tandogan, Tamer |d 1965- |e VerfasserIn |0 (DE-588)129861812 |0 (DE-627)48236419X |0 (DE-576)297874578 |4 aut | |
| 700 | 1 | |a Khoramnia, Ramin |d 1980- |e VerfasserIn |0 (DE-588)132573954 |0 (DE-627)523957173 |0 (DE-576)299234355 |4 aut | |
| 700 | 1 | |a Auffarth, Gerd U. |d 1964- |e VerfasserIn |0 (DE-588)123385261 |0 (DE-627)577130420 |0 (DE-576)293687277 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t Journal of cataract and refractive surgery |d Hagerstown, MD : Wolters Kluwer Health, 1986 |g 45(2019), 7, Seite 1020-1025 |h Online-Ressource |w (DE-627)320594203 |w (DE-600)2019330-0 |w (DE-576)260773891 |x 1873-4502 |7 nnas |a The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens |
| 773 | 1 | 8 | |g volume:45 |g year:2019 |g number:7 |g pages:1020-1025 |g extent:6 |a The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jcrs.2019.01.025 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 856 | 4 | 0 | |u https://journals.lww.com/jcrs/FullText/2019/07000/The_impact_of_glistenings_on_the_optical_quality.21.aspx |x Verlag |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20200420 | ||
| 993 | |a Article | ||
| 994 | |a 2019 | ||
| 998 | |g 123385261 |a Auffarth, Gerd U. |m 123385261:Auffarth, Gerd U. |d 910000 |d 910900 |e 910000PA123385261 |e 910900PA123385261 |k 0/910000/ |k 1/910000/910900/ |p 6 |y j | ||
| 998 | |g 132573954 |a Khoramnia, Ramin |m 132573954:Khoramnia, Ramin |d 910000 |d 910900 |e 910000PK132573954 |e 910900PK132573954 |k 0/910000/ |k 1/910000/910900/ |p 5 | ||
| 998 | |g 129861812 |a Tandogan, Tamer |m 129861812:Tandogan, Tamer |d 50000 |e 50000PT129861812 |k 0/50000/ |p 4 | ||
| 998 | |g 112972557X |a Yildirim, Timur Mert |m 112972557X:Yildirim, Timur Mert |d 910000 |d 910900 |e 910000PY112972557X |e 910900PY112972557X |k 0/910000/ |k 1/910000/910900/ |p 3 | ||
| 998 | |g 1185406743 |a Łabuz, Grzegorz |m 1185406743:Łabuz, Grzegorz |d 910000 |d 910900 |e 910000PŁ1185406743 |e 910900PŁ1185406743 |k 0/910000/ |k 1/910000/910900/ |p 2 | ||
| 998 | |g 120866543X |a Weindler, Jan N. |m 120866543X:Weindler, Jan N. |d 910000 |d 910900 |e 910000PW120866543X |e 910900PW120866543X |k 0/910000/ |k 1/910000/910900/ |p 1 |x j | ||
| 999 | |a KXP-PPN1695023226 |e 3627526473 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"type":{"media":"Online-Ressource","bibl":"article-journal"},"title":[{"title_sort":"impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens","title":"The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lens"}],"name":{"displayForm":["Jan N. Weindler, MD, Grzegorz Łabuz, PhD, Timur M. Yildirim, MD, Tamer Tandogan, MD, Ramin Khoramnia, MD, FEBO, Gerd U. Auffarth, MD, PhD"]},"origin":[{"dateIssuedKey":"2019","dateIssuedDisp":"2019"}],"id":{"eki":["1695023226"],"doi":["10.1016/j.jcrs.2019.01.025"]},"person":[{"family":"Weindler","display":"Weindler, Jan N.","role":"aut","given":"Jan N."},{"given":"Grzegorz","family":"Łabuz","display":"Łabuz, Grzegorz","role":"aut"},{"display":"Yildirim, Timur Mert","role":"aut","family":"Yildirim","given":"Timur Mert"},{"family":"Tandogan","display":"Tandogan, Tamer","role":"aut","given":"Tamer"},{"given":"Ramin","display":"Khoramnia, Ramin","role":"aut","family":"Khoramnia"},{"family":"Auffarth","display":"Auffarth, Gerd U.","role":"aut","given":"Gerd U."}],"note":["Gesehen am 20.04.2020"],"language":["eng"],"recId":"1695023226","physDesc":[{"extent":"6 S."}],"relHost":[{"note":["Gesehen am 02.08.24"],"physDesc":[{"extent":"Online-Ressource"}],"recId":"320594203","type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Journal of cataract & refractive surgery"}],"pubHistory":["12.1986 -"],"language":["eng"],"disp":"The impact of glistenings on the optical quality of a hydrophobic acrylic intraocular lensJournal of cataract and refractive surgery","title":[{"title":"Journal of cataract and refractive surgery","title_sort":"Journal of cataract and refractive surgery"}],"name":{"displayForm":["American Society of Cataract and Refractive Surgery"]},"id":{"issn":["1873-4502"],"eki":["320594203"],"zdb":["2019330-0"]},"part":{"volume":"45","extent":"6","issue":"7","pages":"1020-1025","text":"45(2019), 7, Seite 1020-1025","year":"2019"},"origin":[{"publisher":"Wolters Kluwer Health ; American Society of Cataract and Refractive Surgery ; Elsevier","publisherPlace":"Hagerstown, MD ; Fairfax, Va ; Amsterdam [u.a.]","dateIssuedKey":"2020","dateIssuedDisp":"2020-"}]}]} | ||
| SRT | |a WEINDLERJAIMPACTOFGL2019 | ||