Molecular diagnostic profiling of lung cancer specimens with a semiconductor-based massive parallel sequencing approach: feasibility, costs, and performance compared with conventional sequencing
In the context of personalized oncology, screening for somatic tumor mutations is crucial for prediction of an individual patient's response to therapy. Massive parallel sequencing (MPS) has been suggested for routine diagnostics, but this technology has not been sufficiently evaluated with res...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
21 August 2013
|
| In: |
The journal of molecular diagnostics
Year: 2013, Volume: 15, Issue: 6, Pages: 765-775 |
| ISSN: | 1943-7811 |
| DOI: | 10.1016/j.jmoldx.2013.06.002 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jmoldx.2013.06.002 |
| Author Notes: | Volker Endris, Roland Penzel, Arne. Warth, Alexander Muckenhuber, Peter Schirmacher, Albrecht Stenzinger, and Wilko. Weichert |
MARC
| LEADER | 00000caa a2200000 c 4500 | ||
|---|---|---|---|
| 001 | 1747638269 | ||
| 003 | DE-627 | ||
| 005 | 20220819100110.0 | ||
| 007 | cr uuu---uuuuu | ||
| 008 | 210205s2013 xx |||||o 00| ||eng c | ||
| 024 | 7 | |a 10.1016/j.jmoldx.2013.06.002 |2 doi | |
| 035 | |a (DE-627)1747638269 | ||
| 035 | |a (DE-599)KXP1747638269 | ||
| 035 | |a (OCoLC)1341391841 | ||
| 040 | |a DE-627 |b ger |c DE-627 |e rda | ||
| 041 | |a eng | ||
| 084 | |a 33 |2 sdnb | ||
| 100 | 1 | |a Endris, Volker |e VerfasserIn |0 (DE-588)1063753686 |0 (DE-627)812590961 |0 (DE-576)422898198 |4 aut | |
| 245 | 1 | 0 | |a Molecular diagnostic profiling of lung cancer specimens with a semiconductor-based massive parallel sequencing approach |b feasibility, costs, and performance compared with conventional sequencing |c Volker Endris, Roland Penzel, Arne. Warth, Alexander Muckenhuber, Peter Schirmacher, Albrecht Stenzinger, and Wilko. Weichert |
| 264 | 1 | |c 21 August 2013 | |
| 300 | |a 11 | ||
| 336 | |a Text |b txt |2 rdacontent | ||
| 337 | |a Computermedien |b c |2 rdamedia | ||
| 338 | |a Online-Ressource |b cr |2 rdacarrier | ||
| 500 | |a Gesehen am 05.02.2021 | ||
| 520 | |a In the context of personalized oncology, screening for somatic tumor mutations is crucial for prediction of an individual patient's response to therapy. Massive parallel sequencing (MPS) has been suggested for routine diagnostics, but this technology has not been sufficiently evaluated with respect to feasibility, reliability, and cost effectiveness with routine diagnostic formalin-fixed, paraffin-embedded material. We performed ultradeep targeted semiconductor-based MPS (190 amplicons covering hotspot mutations in 46 genes) in a variety of formalin-fixed, paraffin-embedded diagnostic samples of lung adenocarcinoma tissue with known EGFR mutations (n = 28). The samples reflected the typical spectrum of tissue material for diagnostics, including small biopsies and samples with low tumor-cell content. Using MPS, we successfully sequenced all samples, with a mean read depth of 2947 reads per amplicon. High-quality sequence reads were obtained from samples containing ≥10% tumor material. In all but one sample, variant calling identified the same EGFR mutations as were detected by conventional Sanger sequencing. Moreover, we identified 43 additional mutations in 17 genes and detected amplifications in the EGFR and ERBB2 genes. MPS performance was reliable and independent of the type of material, as well as of the fixation and extraction methods, but was influenced by tumor-cell content and the degree of DNA degradation. Using sample multiplexing, focused MPS approached diagnostically acceptable cost rates. | ||
| 700 | 1 | |a Penzel, Roland |e VerfasserIn |0 (DE-588)102044021X |0 (DE-627)691221316 |0 (DE-576)360421083 |4 aut | |
| 700 | 1 | |a Warth, Arne |d 1979- |e VerfasserIn |0 (DE-588)132646145 |0 (DE-627)524716927 |0 (DE-576)260019755 |4 aut | |
| 700 | 1 | |a Muckenhuber, Alexander |e VerfasserIn |0 (DE-588)1098197038 |0 (DE-627)857489399 |0 (DE-576)469023473 |4 aut | |
| 700 | 1 | |a Schirmacher, Peter |d 1961- |e VerfasserIn |0 (DE-588)1020440112 |0 (DE-627)691221197 |0 (DE-576)360427448 |4 aut | |
| 700 | 1 | |a Stenzinger, Albrecht |e VerfasserIn |0 (DE-588)139606106 |0 (DE-627)703395238 |0 (DE-576)312432755 |4 aut | |
| 700 | 1 | |a Weichert, Wilko |d 1970-2023 |e VerfasserIn |0 (DE-588)123509106 |0 (DE-627)56134650X |0 (DE-576)293740461 |4 aut | |
| 773 | 0 | 8 | |i Enthalten in |t The journal of molecular diagnostics |d Amsterdam [u.a.] : Elsevier, 1999 |g 15(2013), 6, Seite 765-775 |h Online-Ressource |w (DE-627)324916922 |w (DE-600)2032654-3 |w (DE-576)309203805 |x 1943-7811 |7 nnas |a Molecular diagnostic profiling of lung cancer specimens with a semiconductor-based massive parallel sequencing approach feasibility, costs, and performance compared with conventional sequencing |
| 773 | 1 | 8 | |g volume:15 |g year:2013 |g number:6 |g pages:765-775 |g extent:11 |a Molecular diagnostic profiling of lung cancer specimens with a semiconductor-based massive parallel sequencing approach feasibility, costs, and performance compared with conventional sequencing |
| 856 | 4 | 0 | |u https://doi.org/10.1016/j.jmoldx.2013.06.002 |x Verlag |x Resolving-System |z lizenzpflichtig |3 Volltext |
| 951 | |a AR | ||
| 992 | |a 20210205 | ||
| 993 | |a Article | ||
| 994 | |a 2013 | ||
| 998 | |g 123509106 |a Weichert, Wilko |m 123509106:Weichert, Wilko |d 910000 |d 912000 |e 910000PW123509106 |e 912000PW123509106 |k 0/910000/ |k 1/910000/912000/ |p 7 |y j | ||
| 998 | |g 139606106 |a Stenzinger, Albrecht |m 139606106:Stenzinger, Albrecht |d 910000 |d 912000 |e 910000PS139606106 |e 912000PS139606106 |k 0/910000/ |k 1/910000/912000/ |p 6 | ||
| 998 | |g 1020440112 |a Schirmacher, Peter |m 1020440112:Schirmacher, Peter |d 910000 |d 912000 |e 910000PS1020440112 |e 912000PS1020440112 |k 0/910000/ |k 1/910000/912000/ |p 5 | ||
| 998 | |g 1098197038 |a Muckenhuber, Alexander |m 1098197038:Muckenhuber, Alexander |d 910000 |d 912000 |e 910000PM1098197038 |e 912000PM1098197038 |k 0/910000/ |k 1/910000/912000/ |p 4 | ||
| 998 | |g 132646145 |a Warth, Arne |m 132646145:Warth, Arne |d 910000 |d 912000 |e 910000PW132646145 |e 912000PW132646145 |k 0/910000/ |k 1/910000/912000/ |p 3 | ||
| 998 | |g 102044021X |a Penzel, Roland |m 102044021X:Penzel, Roland |d 910000 |d 912000 |e 910000PP102044021X |e 912000PP102044021X |k 0/910000/ |k 1/910000/912000/ |p 2 | ||
| 998 | |g 1063753686 |a Endris, Volker |m 1063753686:Endris, Volker |d 910000 |d 912000 |e 910000PE1063753686 |e 912000PE1063753686 |k 0/910000/ |k 1/910000/912000/ |p 1 |x j | ||
| 999 | |a KXP-PPN1747638269 |e 3849407039 | ||
| BIB | |a Y | ||
| SER | |a journal | ||
| JSO | |a {"relHost":[{"disp":"Molecular diagnostic profiling of lung cancer specimens with a semiconductor-based massive parallel sequencing approach feasibility, costs, and performance compared with conventional sequencingThe journal of molecular diagnostics","recId":"324916922","titleAlt":[{"title":"JMD online"}],"language":["eng"],"pubHistory":["1.1999,1(Nov.) -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"name":{"displayForm":["the American Society for Investigative Pathology and the Association for Molecular Pathology"]},"origin":[{"dateIssuedDisp":"1999-","publisher":"Elsevier ; Soc.","publisherPlace":"Amsterdam [u.a.] ; Bethesda, Md.","dateIssuedKey":"1999"}],"corporate":[{"role":"isb","display":"American Society for Investigative Pathology"},{"role":"isb","display":"Association for Molecular Pathology"}],"title":[{"title":"The journal of molecular diagnostics","title_sort":"journal of molecular diagnostics"}],"id":{"eki":["324916922"],"zdb":["2032654-3"],"issn":["1943-7811"]},"part":{"extent":"11","issue":"6","text":"15(2013), 6, Seite 765-775","volume":"15","year":"2013","pages":"765-775"},"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 17.01.20"]}],"note":["Gesehen am 05.02.2021"],"physDesc":[{"extent":"11 S."}],"type":{"media":"Online-Ressource","bibl":"article-journal"},"id":{"doi":["10.1016/j.jmoldx.2013.06.002"],"eki":["1747638269"]},"language":["eng"],"title":[{"title_sort":"Molecular diagnostic profiling of lung cancer specimens with a semiconductor-based massive parallel sequencing approach","subtitle":"feasibility, costs, and performance compared with conventional sequencing","title":"Molecular diagnostic profiling of lung cancer specimens with a semiconductor-based massive parallel sequencing approach"}],"person":[{"display":"Endris, Volker","given":"Volker","family":"Endris","role":"aut"},{"display":"Penzel, Roland","given":"Roland","family":"Penzel","role":"aut"},{"role":"aut","display":"Warth, Arne","given":"Arne","family":"Warth"},{"role":"aut","display":"Muckenhuber, Alexander","given":"Alexander","family":"Muckenhuber"},{"given":"Peter","display":"Schirmacher, Peter","family":"Schirmacher","role":"aut"},{"family":"Stenzinger","display":"Stenzinger, Albrecht","given":"Albrecht","role":"aut"},{"family":"Weichert","display":"Weichert, Wilko","given":"Wilko","role":"aut"}],"recId":"1747638269","origin":[{"dateIssuedDisp":"21 August 2013","dateIssuedKey":"2013"}],"name":{"displayForm":["Volker Endris, Roland Penzel, Arne. Warth, Alexander Muckenhuber, Peter Schirmacher, Albrecht Stenzinger, and Wilko. Weichert"]}} | ||
| SRT | |a ENDRISVOLKMOLECULARD2120 | ||