Reproducibility of peri-implant probing using a force-controlled probe

The aim of the present study was to evaluate the reproducibility of probing depth (PD) and vertical attachment level (PAL-V) measurements at endosseous implants. Twenty partially edentulous patients who had received 44 Frialit-2 and 30 Astra implants between 1994 and 1996 were examined. At all teeth...

Full description

Saved in:
Bibliographic Details
Main Authors: Eickholz, Peter (Author) , Grotkamp, Frank-Ludger (Author) , Staehle, Hans Jörg (Author) , Steveling, Helmut (Author) , Mühling, Joachim (Author)
Format: Article (Journal)
Language:English
Published: 2001
In: Clinical oral implants research
Year: 2001, Volume: 12, Issue: 2, Pages: 153-158
ISSN:1600-0501
DOI:https://doi.org/10.1034/j.1600-0501.2001.012002153.x
Online Access:Resolving-System, lizenzpflichtig, Volltext: https://doi.org/https://doi.org/10.1034/j.1600-0501.2001.012002153.x
Verlag, lizenzpflichtig, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1034/j.1600-0501.2001.012002153.x
Get full text
Author Notes:Peter Eickholz, Frank L. Grotkamp, Hans J. Staehle, Helmut Steveling, Joachim Mühling

MARC

LEADER 00000caa a2200000 c 4500
001 1748207636
003 DE-627
005 20220819104638.0
007 cr uuu---uuuuu
008 210212s2001 xx |||||o 00| ||eng c
024 7 |a 10.1034/j.1600-0501.2001.012002153.x  |2 doi 
035 |a (DE-627)1748207636 
035 |a (DE-599)KXP1748207636 
035 |a (OCoLC)1341393092 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Eickholz, Peter  |d 1963-  |e VerfasserIn  |0 (DE-588)17206063X  |0 (DE-627)69696533X  |0 (DE-576)13293485X  |4 aut 
245 1 0 |a Reproducibility of peri-implant probing using a force-controlled probe  |c Peter Eickholz, Frank L. Grotkamp, Hans J. Staehle, Helmut Steveling, Joachim Mühling 
264 1 |c 2001 
300 |a 6 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a First published: 19 January 2002 
500 |a Elektronische Reproduktion der Druck-Ausgabe 
500 |a Gesehen am 12.02.2021 
520 |a The aim of the present study was to evaluate the reproducibility of probing depth (PD) and vertical attachment level (PAL-V) measurements at endosseous implants. Twenty partially edentulous patients who had received 44 Frialit-2 and 30 Astra implants between 1994 and 1996 were examined. At all teeth and implants, clinical parameters (GI, PlI, PD, PAL-V) were measured at 6 sites using the flexible plastic version of the universal explorer TPS probe. At the implants and at teeth that were in similar locations compared to the implants, PD and PAL-V measurements were repeated. For each of the 20 probes that had been used for clinical examination of the 20 patients, the probing force was assessed using a precision balance. As a measure of intraexaminer reproducibility, the following standard deviations of single PD and PAL-V measurements were calculated: Frialit-2: 0.71/0.74 mm; Astra: 0.72/0.75 mm; tooth: 0.59/0.57 mm (PD/PAL-V). Stepwise multiple regression analysis revealed implant/tooth position and GI to influence PD and PAL-V measurement error (P<0.001). At anterior teeth, a lower variability was observed than at posterior teeth (P<0.001). PD and PAL-V measurement error were higher at implants than at teeth and influenced by patients. The respective models explained 13% and 17% of the variability of the dependent variable (PD/PAL-V), respectively. Intraexaminer variability of PD and PAL-V measurements at implants tended to be higher than at teeth. Multivariate analysis of variance revealed probe and probe holder to statistically significantly (P<0.001) influence probing force. However, the differences in probing force between the various probe heads were very small. They reached a maximum of 0.054 N between probe 3 and 14 and may be looked upon as clinically irrelevant. 
650 4 |a peri-implant probing 
650 4 |a reproducibility 
650 4 |a TPS probe 
700 1 |a Grotkamp, Frank-Ludger  |d 1972-  |e VerfasserIn  |0 (DE-588)121733866  |0 (DE-627)705633446  |0 (DE-576)292856830  |4 aut 
700 1 |a Staehle, Hans Jörg  |d 1953-  |e VerfasserIn  |0 (DE-588)172383102  |0 (DE-627)697325644  |0 (DE-576)133247309  |4 aut 
700 1 |a Steveling, Helmut  |e VerfasserIn  |0 (DE-588)1076685358  |0 (DE-627)835249255  |0 (DE-576)169538575  |4 aut 
700 1 |a Mühling, Joachim  |d 1948-2009  |e VerfasserIn  |0 (DE-588)172266041  |0 (DE-627)697176452  |0 (DE-576)133134032  |4 aut 
773 0 8 |i Enthalten in  |t Clinical oral implants research  |d Oxford : Wiley-Blackwell, 1990  |g 12(2001), 2, Seite 153-158  |h Online-Ressource  |w (DE-627)324484526  |w (DE-600)2027104-9  |w (DE-576)09388883X  |x 1600-0501  |7 nnas  |a Reproducibility of peri-implant probing using a force-controlled probe 
773 1 8 |g volume:12  |g year:2001  |g number:2  |g pages:153-158  |g extent:6  |a Reproducibility of peri-implant probing using a force-controlled probe 
856 4 0 |u https://doi.org/https://doi.org/10.1034/j.1600-0501.2001.012002153.x  |x Resolving-System  |x Verlag  |z lizenzpflichtig  |3 Volltext 
856 4 0 |u https://onlinelibrary.wiley.com/doi/abs/10.1034/j.1600-0501.2001.012002153.x  |x Verlag  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210212 
993 |a Article 
994 |a 2001 
998 |g 172266041  |a Mühling, Joachim  |m 172266041:Mühling, Joachim  |d 910000  |d 910800  |e 910000PM172266041  |e 910800PM172266041  |k 0/910000/  |k 1/910000/910800/  |p 5  |y j 
998 |g 1076685358  |a Steveling, Helmut  |m 1076685358:Steveling, Helmut  |d 910000  |d 910800  |e 910000PS1076685358  |e 910800PS1076685358  |k 0/910000/  |k 1/910000/910800/  |p 4 
998 |g 172383102  |a Staehle, Hans Jörg  |m 172383102:Staehle, Hans Jörg  |d 910000  |d 910800  |e 910000PS172383102  |e 910800PS172383102  |k 0/910000/  |k 1/910000/910800/  |p 3 
998 |g 121733866  |a Grotkamp, Frank-Ludger  |m 121733866:Grotkamp, Frank-Ludger  |d 50000  |e 50000PG121733866  |k 0/50000/  |p 2 
998 |g 17206063X  |a Eickholz, Peter  |m 17206063X:Eickholz, Peter  |d 910000  |d 910800  |e 910000PE17206063X  |e 910800PE17206063X  |k 0/910000/  |k 1/910000/910800/  |p 1  |x j 
999 |a KXP-PPN1748207636  |e 385175963X 
BIB |a Y 
SER |a journal 
JSO |a {"type":{"bibl":"article-journal","media":"Online-Ressource"},"title":[{"title":"Reproducibility of peri-implant probing using a force-controlled probe","title_sort":"Reproducibility of peri-implant probing using a force-controlled probe"}],"name":{"displayForm":["Peter Eickholz, Frank L. Grotkamp, Hans J. Staehle, Helmut Steveling, Joachim Mühling"]},"id":{"doi":["10.1034/j.1600-0501.2001.012002153.x"],"eki":["1748207636"]},"origin":[{"dateIssuedKey":"2001","dateIssuedDisp":"2001"}],"relHost":[{"title":[{"title":"Clinical oral implants research","title_sort":"Clinical oral implants research","subtitle":"official publication of the European Association for Osseointegration"}],"disp":"Reproducibility of peri-implant probing using a force-controlled probeClinical oral implants research","pubHistory":["1.1990 -"],"type":{"media":"Online-Ressource","bibl":"periodical"},"recId":"324484526","language":["eng"],"physDesc":[{"extent":"Online-Ressource"}],"note":["Gesehen am 28.03.2022"],"part":{"text":"12(2001), 2, Seite 153-158","issue":"2","volume":"12","pages":"153-158","year":"2001","extent":"6"},"origin":[{"publisherPlace":"Oxford ; Copenhagen ; Oxford [u.a.]","publisher":"Wiley-Blackwell ; Munksgaard ; Blackwell","dateIssuedKey":"1990","dateIssuedDisp":"1990-"}],"id":{"zdb":["2027104-9"],"doi":["10.1111/(ISSN)1600-0501"],"issn":["1600-0501"],"eki":["324484526"]}}],"physDesc":[{"extent":"6 S."}],"language":["eng"],"recId":"1748207636","note":["First published: 19 January 2002","Elektronische Reproduktion der Druck-Ausgabe","Gesehen am 12.02.2021"],"person":[{"given":"Peter","family":"Eickholz","role":"aut","roleDisplay":"VerfasserIn","display":"Eickholz, Peter"},{"display":"Grotkamp, Frank-Ludger","role":"aut","roleDisplay":"VerfasserIn","given":"Frank-Ludger","family":"Grotkamp"},{"role":"aut","roleDisplay":"VerfasserIn","display":"Staehle, Hans Jörg","given":"Hans Jörg","family":"Staehle"},{"roleDisplay":"VerfasserIn","role":"aut","display":"Steveling, Helmut","family":"Steveling","given":"Helmut"},{"roleDisplay":"VerfasserIn","role":"aut","display":"Mühling, Joachim","family":"Mühling","given":"Joachim"}]} 
SRT |a EICKHOLZPEREPRODUCIB2001