Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery: a randomised, double-blind interventional study

Potential sources of error in dosage planning in strabismus surgery are (a) prismatic side-effects of spectacle lenses when measuring the preoperative angle with the alternating prism cover test and (b) a potential influence of eye ball axial length on dose response. As both errors take effect in op...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Beisse, Flemming (VerfasserIn) , Koch, Matthias (VerfasserIn) , Uhlmann, Lorenz (VerfasserIn) , Beisse, Christina (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: 29 April 2020
In: Graefe's archive for clinical and experimental ophthalmology
Year: 2020, Jahrgang: 258, Heft: 6, Pages: 1319-1326
ISSN:1435-702X
DOI:10.1007/s00417-020-04690-z
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1007/s00417-020-04690-z
Volltext
Verfasserangaben:Flemming Beisse, Matthias Koch, Lorenz Uhlmann, Christina Beisse

MARC

LEADER 00000caa a2200000 c 4500
001 1769940545
003 DE-627
005 20220208230847.0
007 cr uuu---uuuuu
008 210909s2020 xx |||||o 00| ||eng c
024 7 |a 10.1007/s00417-020-04690-z  |2 doi 
035 |a (DE-627)1769940545 
035 |a (DE-599)KXP1769940545 
035 |a (OCoLC)1295680540 
040 |a DE-627  |b ger  |c DE-627  |e rda 
041 |a eng 
084 |a 33  |2 sdnb 
100 1 |a Beisse, Flemming  |d 1970-  |e VerfasserIn  |0 (DE-588)120850052  |0 (DE-627)705037576  |0 (DE-576)180187163  |4 aut 
245 1 0 |a Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery  |b a randomised, double-blind interventional study  |c Flemming Beisse, Matthias Koch, Lorenz Uhlmann, Christina Beisse 
264 1 |c 29 April 2020 
300 |a 8 
336 |a Text  |b txt  |2 rdacontent 
337 |a Computermedien  |b c  |2 rdamedia 
338 |a Online-Ressource  |b cr  |2 rdacarrier 
500 |a Gesehen am 09.09.2021 
520 |a Potential sources of error in dosage planning in strabismus surgery are (a) prismatic side-effects of spectacle lenses when measuring the preoperative angle with the alternating prism cover test and (b) a potential influence of eye ball axial length on dose response. As both errors take effect in opposite directions, many strabismus surgeons set aside their consideration. This study investigates whether considering both factors for dosage planning yields better operative results. 
700 1 |a Koch, Matthias  |e VerfasserIn  |0 (DE-588)1216657610  |0 (DE-627)1727904990  |4 aut 
700 1 |a Uhlmann, Lorenz  |d 1986-  |e VerfasserIn  |0 (DE-588)106747627X  |0 (DE-627)818782021  |0 (DE-576)426685660  |4 aut 
700 1 |a Beisse, Christina  |e VerfasserIn  |0 (DE-588)1045056405  |0 (DE-627)773561579  |0 (DE-576)398365490  |4 aut 
773 0 8 |i Enthalten in  |t Graefe's archive for clinical and experimental ophthalmology  |d Berlin : Springer, 1982  |g 258(2020), 6, Seite 1319-1326  |h Online-Ressource  |w (DE-627)253723728  |w (DE-600)1459159-5  |w (DE-576)072372931  |x 1435-702X  |7 nnas  |a Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery a randomised, double-blind interventional study 
773 1 8 |g volume:258  |g year:2020  |g number:6  |g pages:1319-1326  |g extent:8  |a Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery a randomised, double-blind interventional study 
856 4 0 |u https://doi.org/10.1007/s00417-020-04690-z  |x Verlag  |x Resolving-System  |z lizenzpflichtig  |3 Volltext 
951 |a AR 
992 |a 20210909 
993 |a Article 
994 |a 2020 
998 |g 1045056405  |a Beisse, Christina  |m 1045056405:Beisse, Christina  |d 910000  |d 910900  |d 50000  |e 910000PB1045056405  |e 910900PB1045056405  |e 50000PB1045056405  |k 0/910000/  |k 1/910000/910900/  |k 0/50000/  |p 4  |y j 
998 |g 106747627X  |a Uhlmann, Lorenz  |m 106747627X:Uhlmann, Lorenz  |p 3 
998 |g 1216657610  |a Koch, Matthias  |m 1216657610:Koch, Matthias  |d 910000  |d 910900  |e 910000PK1216657610  |e 910900PK1216657610  |k 0/910000/  |k 1/910000/910900/  |p 2 
998 |g 120850052  |a Beisse, Flemming  |m 120850052:Beisse, Flemming  |d 910000  |d 910900  |e 910000PB120850052  |e 910900PB120850052  |k 0/910000/  |k 1/910000/910900/  |p 1  |x j 
999 |a KXP-PPN1769940545  |e 3976027111 
BIB |a Y 
SER |a journal 
JSO |a {"id":{"eki":["1769940545"],"doi":["10.1007/s00417-020-04690-z"]},"origin":[{"dateIssuedDisp":"29 April 2020","dateIssuedKey":"2020"}],"name":{"displayForm":["Flemming Beisse, Matthias Koch, Lorenz Uhlmann, Christina Beisse"]},"recId":"1769940545","person":[{"given":"Flemming","role":"aut","family":"Beisse","display":"Beisse, Flemming"},{"display":"Koch, Matthias","family":"Koch","given":"Matthias","role":"aut"},{"family":"Uhlmann","role":"aut","given":"Lorenz","display":"Uhlmann, Lorenz"},{"family":"Beisse","role":"aut","given":"Christina","display":"Beisse, Christina"}],"title":[{"title_sort":"Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery","subtitle":"a randomised, double-blind interventional study","title":"Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery"}],"type":{"bibl":"article-journal","media":"Online-Ressource"},"physDesc":[{"extent":"8 S."}],"language":["eng"],"relHost":[{"title":[{"title_sort":"Graefe's archive for clinical and experimental ophthalmology","subtitle":"official organ of the Club Jules Gonin","title":"Graefe's archive for clinical and experimental ophthalmology"}],"pubHistory":["Volume 218, issue 1 (January 1982)-"],"physDesc":[{"extent":"Online-Ressource"}],"language":["eng"],"type":{"media":"Online-Ressource","bibl":"periodical"},"titleAlt":[{"title":"Archive for clinical and experimental ophthalmology"}],"note":["Gesehen am 07.04.2025","Ungezählte Beil.: Supplement"],"part":{"text":"258(2020), 6, Seite 1319-1326","extent":"8","volume":"258","pages":"1319-1326","issue":"6","year":"2020"},"id":{"eki":["253723728"],"issn":["1435-702X"],"zdb":["1459159-5"]},"origin":[{"dateIssuedKey":"1982","publisher":"Springer ; Springer","dateIssuedDisp":"1982-","publisherPlace":"Berlin ; Heidelberg ; Berlin ; Heidelberg ; New York, NY"}],"disp":"Consideration of eyeball length and prismatic side-effects of spectacle lenses in strabismus surgery a randomised, double-blind interventional studyGraefe's archive for clinical and experimental ophthalmology","recId":"253723728"}],"note":["Gesehen am 09.09.2021"]} 
SRT |a BEISSEFLEMCONSIDERAT2920