Continuous noninvasive arterial pressure: assessment in older and high-risk patients under analgesic sedation

Objective - To assess the role of continuous noninvasive arterial pressure (CNAP) in elderly, high-risk patients with pronounced variation in arterial pressure (AP) under analgesic sedation. - Methods - Twenty-nine patients were analyzed while undergoing elective transfemoral aortic valve implantati...

Full description

Saved in:
Bibliographic Details
Main Authors: Schramm, Christoph (Author) , Baat, Lisa (Author) , Plaschke, Konstanze (Author)
Format: Article (Journal)
Language:English
Published: [December 2011]
In: Blood pressure monitoring
Year: 2011, Volume: 16, Issue: 6, Pages: 270-276
ISSN:1473-5725
DOI:10.1097/MBP.0b013e32834d777f
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1097/MBP.0b013e32834d777f
Verlag, lizenzpflichtig, Volltext: https://journals.lww.com/bpmonitoring/Abstract/2011/12000/Continuous_noninvasive_arterial_pressure_.2.aspx
Get full text
Author Notes:Christoph Schramm, Lisa Baat, Konstanze Plaschke
Description
Summary:Objective - To assess the role of continuous noninvasive arterial pressure (CNAP) in elderly, high-risk patients with pronounced variation in arterial pressure (AP) under analgesic sedation. - Methods - Twenty-nine patients were analyzed while undergoing elective transfemoral aortic valve implantation procedures during periods of normal blood pressure, hypotension, and hypertension with standard invasive arterial pressures (IAP). Systolic, diastolic, and mean IAP were compared with those obtained by CNAP. Data were analyzed to determine precision (i.e. measurement error) and accuracy (i.e. systematic error) during different periods of AP for agreement of the two methods. In addition, we compared the two methods during intervals of functional cardiac arrests (rapid pacing) in terms of amplitude and frequency of rapid changes in AP. - Results - No significant differences in precision were observed between CNAP measurements and IAP measurements. CNAP accuracy was −8.3*, 6.4, and 0.6 mmHg in normotensive, −20.5*, 4.4, and −5.5 mmHg in hypertensive, and −4.8, 9.4, and 4.5 mmHg in hypotensive conditions (*P<0.05). The frequency of AP pairs with a difference of ±15 mmHg (limits of agreement) or less was 59.5, 71.7, and 76.5% in normotensive, 33.1, 72.9, and 66.9% in hypertensive, and 59.5, 71.7, and 76.5% in hypotensive periods for systolic, diastolic, and mean AP, respectively. Rapid pacing intervals showed a significant difference in systolic measurements; whereas the differences between CNAP and IAP for diastolic and mean AP were minimal. - Conclusion - The agreement between the two techniques used in this study of elderly high-risk patients under analgesic sedation is similar to that found in studies performed under general anesthesia. The best agreement was detected in hypotensive periods.
Item Description:Gesehen am 26.10.2022
Physical Description:Online Resource
ISSN:1473-5725
DOI:10.1097/MBP.0b013e32834d777f