Reproducibility of left and right ventricular mass measurements with cardiac CT
Background - Cardiac CT provides volumetric data that enables characterization of the myocardium. Objective - We evaluated intraobserver, interobserver, and interstudy reproducibility of left ventricular (LV) and right ventricular (RV) mass quantification with cardiac CT. - Methods - Thirty-eight pa...
Saved in:
| Main Authors: | , , , , , , , |
|---|---|
| Format: | Article (Journal) |
| Language: | English |
| Published: |
[September-October 2011]
|
| In: |
Journal of cardiovascular computed tomography
Year: 2011, Volume: 5, Issue: 5, Pages: 317-324 |
| ISSN: | 1876-861X |
| DOI: | 10.1016/j.jcct.2011.08.004 |
| Online Access: | Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.jcct.2011.08.004 Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S1934592511003182 |
| Author Notes: | Florian Schwarz, MD, Richard Takx, BS, U. Joseph Schoepf, MD, Yeong Shyan Lee, MB, BCh, FRCR, Balazs Ruzsics, MD PhD, Eva Maria Gassner, MD, Salvatore Chiaramida, MD, Thomas Henzler, MD |
| Summary: | Background - Cardiac CT provides volumetric data that enables characterization of the myocardium. Objective - We evaluated intraobserver, interobserver, and interstudy reproducibility of left ventricular (LV) and right ventricular (RV) mass quantification with cardiac CT. - Methods - Thirty-eight patients who underwent cardiac CT twice within 365 days were included in this analysis. Functional reconstructions in 10% steps throughout the R-R interval and axial 1.5-mm sections were used. Semiautomatic contour detection was used to trace epicardial and endocardial borders in all cardiac phases for calculation of LV and RV ejection fraction, end-diastolic volume, end-systolic volume, cardiac output, stroke volume, and ventricular mass. For each study 2 observers measured LV and RV mass twice. - Results - LV mass parameters derived from semiautomatic contour detection algorithm had excellent intraobserver (r = 1.00), interobserver (r = 0.99), and interstudy (r = 0.99) reproducibility (P < 0.0001). Average end-diastolic LV mass was 146.2 ± 42.9 g at the first CT study and 146.8 ± 44.4 g at the second study. For measuring RV mass, reproducibility was good on all levels (r = 0.78, r = 0.78, and r = 0.68, respectively, with an average end-diastolic mass of 25.7 ± 5.8 g at the first study and 24.4 ± 4.8 g at the second study. - Conclusion - Quantification of LV mass at cardiac CT with the threshold-based, region-growing semiautomatic segmentation analysis software evaluated here is highly observer independent and reproducible. This largely holds true for the estimation of RV mass as well; however, further improvements are needed to optimize reproducibility for RV mass quantification. |
|---|---|
| Item Description: | Gesehen am 28.10.2022 |
| Physical Description: | Online Resource |
| ISSN: | 1876-861X |
| DOI: | 10.1016/j.jcct.2011.08.004 |