Retentive force of telescopic crowns combining fiber-reinforced composite and zirconia

Purpose: This study investigated changes in the retentive force of telescopic crowns fabricated by combining a zirconia primary crown and a fiber-reinforced composite (FRC) secondary crown.Methods: Primary zirconia crowns were produced with a nominal convergence angle of 0°. Forty-eight secondary cr...

Full description

Saved in:
Bibliographic Details
Main Authors: Tasaka, Akinori (Author) , Schwindling, Franz Sebastian (Author) , Rues, Stefan (Author) , Rammelsberg, Peter (Author) , Yamashita, Shuichiro (Author)
Format: Article (Journal)
Language:English
Published: [2022]
In: Journal of prosthodontic research
Year: 2022, Volume: 66, Issue: 2, Pages: 265-271
ISSN:1883-1958
DOI:10.2186/jpr.JPR_D_20_00163
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.2186/jpr.JPR_D_20_00163
Get full text
Author Notes:Akinori Tasaka, Franz Sebastian Schwindling, Stefan Rues, Peter Rammelsberg, Shuichiro Yamashita
Description
Summary:Purpose: This study investigated changes in the retentive force of telescopic crowns fabricated by combining a zirconia primary crown and a fiber-reinforced composite (FRC) secondary crown.Methods: Primary zirconia crowns were produced with a nominal convergence angle of 0°. Forty-eight secondary crowns were milled from FRC and divided into three study groups (n=16/group) based on milling parameters and post-milling adjustment. The offset parameter used for the final milling step of the inner crown surface was adjusted for a tight initial fit in Group 1 (milling offset: +10 µm, i.e., 2 × 10 µm = 20 µm lower inner diameter compared with the CAD file of the crown) and for improved initial fit (milling offset: -10 µm, i.e., an enlargement of the inner crown diameter by 2 × 20 µm = 40 µm in relation to Group 1) in Groups 2 and 3. The inner surfaces of the secondary crowns were polished with diamond paste in Groups 1 and 2, and silicon points were used for Group 3. The retentive force was measured using a universal testing device. The secondary crown was placed on the primary crown, with the final fitting force set to a load of 100 N. This test was conducted before and after aging (10,000 insertion/removal cycles) under dry and wet conditions. A generalized linear model was used to estimate the differences in the retentive force to elucidate the effects of the milling parameters and polishing methods.Results: We realized an initial retentive force of approximately 10 N. In Groups 2 and 3, the difference was statistically significant between the dry and wet conditions before aging (P < 0.05). There was no significant difference between the dry and wet conditions after aging in any of the groups (P > 0.05).Conclusion: An adequate initial retentive force can be achieved with telescopic crowns combining zirconia and FRC.
Item Description:Gesehen am 20.12.2022
Physical Description:Online Resource
ISSN:1883-1958
DOI:10.2186/jpr.JPR_D_20_00163