Same-day repeatability and between-sequence reproducibility of mean ADC in PI-RADS lesions

Purpose - This study aimed to assess repeatability after repositioning (inter-scan), intra-rater, inter-rater and inter-sequence variability of mean apparent diffusion coefficient (ADC) measurements in MRI-detected prostate lesions. - Method - Forty-three patients with suspicion for prostate cancer...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhang, Kevin Sun (Author) , Neelsen, Christian (Author) , Wennmann, Markus (Author) , Glemser, Philip (Author) , Hielscher, Thomas (Author) , Weru, Vivienn (Author) , Görtz, Magdalena (Author) , Schütz, Viktoria (Author) , Stenzinger, Albrecht (Author) , Hohenfellner, Markus (Author) , Schlemmer, Heinz-Peter (Author) , Bonekamp, David (Author)
Format: Article (Journal)
Language:English
Published: August 2023
In: European journal of radiology
Year: 2023, Volume: 165, Pages: 1-11
ISSN:1872-7727
DOI:10.1016/j.ejrad.2023.110898
Online Access:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.ejrad.2023.110898
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0720048X23002127
Get full text
Author Notes:Kevin Sun Zhang, Christian Jan Oliver Neelsen, Markus Wennmann, Philipp Alexander Glemser, Thomas Hielscher, Vivienn Weru, Magdalena Görtz, Viktoria Schütz, Albrecht Stenzinger, Markus Hohenfellner, Heinz-Peter Schlemmer, David Bonekamp
Description
Summary:Purpose - This study aimed to assess repeatability after repositioning (inter-scan), intra-rater, inter-rater and inter-sequence variability of mean apparent diffusion coefficient (ADC) measurements in MRI-detected prostate lesions. - Method - Forty-three patients with suspicion for prostate cancer were included and received a clinical prostate bi-/multiparametric MRI examination with repeat scans of the T2-weighted and two DWI-weighted sequences (ssEPI and rsEPI). Two raters (R1 and R2) performed single-slice, 2D regions of interest (2D-ROIs) and 3D-segmentation-ROIs (3D-ROIs). Mean bias, corresponding limits of agreement (LoA), mean absolute difference, within-subject coefficient of variation (CoV) and repeatability/reproducibility coefficient (RC/RDC) were calculated. Bradley & Blackwood test was used for variance comparison. Linear mixed models (LMM) were used to account for multiple lesions per patient. - Results - Inter-scan repeatability, intra-rater and inter-sequence reproducibility analysis of ADC showed no significant bias. 3D-ROIs demonstrated significantly less variability than 2D-ROIs (p < 0.01). Inter-rater comparison demonstrated small significant systematic bias of 57 × 10-6 mm2/s for 3D-ROIs (p < 0.001). Intra-rater RC, with the lowest variation, was 145 and 189 × 10-6 mm2/s for 3D- and 2D-ROIs, respectively. For 3D-ROIs of ssEPI, RCs and RDCs were 190-198 × 10-6 mm2/s for inter-scan, inter-rater and inter-sequence variation. No significant differences were found for inter-scan, inter-rater and inter-sequence variability. - Conclusions - In a single-scanner setting, single-slice ADC measurements showed considerable variation, which may be lowered using 3D-ROIs. For 3D-ROIs, we propose a cut-off of ∼ 200 × 10-6 mm2/s for differences introduced by repositioning, rater or sequence effects. The results suggest that follow-up measurements should be possible by different raters or sequences.
Item Description:Online verfügbar: 8. Juni 2023, Artikelversion: 16. Juni 2023
Gesehen am 25.08.2023
Physical Description:Online Resource
ISSN:1872-7727
DOI:10.1016/j.ejrad.2023.110898