Acceleration of magnetic resonance fingerprinting reconstruction using denoising and self-attention pyramidal convolutional neural network

Magnetic resonance fingerprinting (MRF) based on echo-planar imaging (EPI) enables whole-brain imaging to rapidly obtain T1 and T2* relaxation time maps. Reconstructing parametric maps from the MRF scanned baselines by the inner-product method is computationally expensive. We aimed to accelerate the...

Full description

Saved in:
Bibliographic Details
Main Authors: Hong, Jia-Sheng (Author) , Hermann, Ingo (Author) , Zöllner, Frank G. (Author) , Schad, Lothar R. (Author) , Wang, Shuu-Jiun (Author) , Lee, Wei-Kai (Author) , Chen, Yung-Lin (Author) , Chang, Yu (Author) , Wu, Yu-Te (Author)
Format: Article (Journal)
Language:English
Published: 7 February 2022
In: Sensors
Year: 2022, Volume: 22, Issue: 3, Pages: 1-17
ISSN:1424-8220
DOI:10.3390/s22031260
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.3390/s22031260
Verlag, kostenfrei, Volltext: https://www.mdpi.com/1424-8220/22/3/1260
Get full text
Author Notes:Jia-Sheng Hong, Ingo Hermann, Frank Gerrit Zöllner, Lothar R. Schad, Shuu-Jiun Wang, Wei-Kai Lee, Yung-Lin Chen, Yu Chang and Yu-Te Wu
Description
Summary:Magnetic resonance fingerprinting (MRF) based on echo-planar imaging (EPI) enables whole-brain imaging to rapidly obtain T1 and T2* relaxation time maps. Reconstructing parametric maps from the MRF scanned baselines by the inner-product method is computationally expensive. We aimed to accelerate the reconstruction of parametric maps for MRF-EPI by using a deep learning model. The proposed approach uses a two-stage model that first eliminates noise and then regresses the parametric maps. Parametric maps obtained by dictionary matching were used as a reference and compared with the prediction results of the two-stage model. MRF-EPI scans were collected from 32 subjects. The signal-to-noise ratio increased significantly after the noise removal by the denoising model. For prediction with scans in the testing dataset, the mean absolute percentage errors between the standard and the final two-stage model were 3.1%, 3.2%, and 1.9% for T1, and 2.6%, 2.3%, and 2.8% for T2* in gray matter, white matter, and lesion locations, respectively. Our proposed two-stage deep learning model can effectively remove noise and accurately reconstruct MRF-EPI parametric maps, increasing the speed of reconstruction and reducing the storage space required by dictionaries.
Item Description:Gesehen am 14.11.2023
Physical Description:Online Resource
ISSN:1424-8220
DOI:10.3390/s22031260