Simultaneous T1, T2 and T2* mapping of the liver with multi-shot MI-SAGE

Purpose - To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. - Methods - Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition...

Full description

Saved in:
Bibliographic Details
Main Authors: Zhang, Ke (Author) , Triphan, Simon M. F. (Author) , Wielpütz, Mark Oliver (Author) , Ziener, Christian H. (Author) , Ladd, Mark E. (Author) , Schlemmer, Heinz-Peter (Author) , Kauczor, Hans-Ulrich (Author) , Kurz, Felix T. (Author) , Sedlaczek, Oliver (Author)
Format: Article (Journal)
Language:English
Published: January 2024
In: Magnetic resonance imaging
Year: 2024, Volume: 105, Pages: 75-81
ISSN:1873-5894
DOI:10.1016/j.mri.2023.11.004
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.mri.2023.11.004
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0730725X2300190X
Get full text
Author Notes:Ke Zhang, Simon M.F. Triphan, Mark O. Wielpütz, Christian H. Ziener, Mark E. Ladd, Heinz-Peter Schlemmer, Hans-Ulrich Kauczor, Felix T. Kurz, Oliver Sedlaczek
Description
Summary:Purpose - To apply multi-shot high-resolution multi inversion spin and gradient echo (MI-SAGE) acquisition for simultaneous liver T1, T2 and T2* mapping. - Methods - Inversion prepared spin- and gradient-echo EPI was developed with ascending slice order across measurements for efficient acquisition with T1, T2, and T2⁎ weighting. Multi-shot EPI was also implemented to minimize distortion and blurring while enabling high in-plane resolution. A dictionary-matching approach was used to fit the images to quantitative parameter maps, which were compared to T1 measured by modified Look-Locker (MOLLI), T1 measured by variable flip angle (VFA), T2 measured by multiple echo time-based Half Fourier Single-shot Turbo spin-Echo (HASTE), T2 measured by radial turbo-spin-echo (rTSE) and T2⁎ measured by multiple gradient echo (MGRE) sequences. - Results - The multi-shot variant of the sequence achieved higher in-plane resolution of 1.7 × 1.7 mm2 with good image quality in 28 s. Derived quantitative maps showed comparable values to conventional mapping methods. As measured in phantom and in vivo, MOLLI, MESE and MGRE give closest values to MISAGE. VFA, HASTE and rTSE show obvious overestimation. - Conclusions - The proposed multi-shot inversion prepared spin- and gradient-echo EPI sequence allows for high-resolution quantitative T1, T2 and T2 liver tissue characterization in a single breath-hold scan.
Item Description:Im Titel sind die Zahlen tiefgestellt
Online verfügbar: 7. November 2023, Artikelversion: 10. November 2023
Gesehen am 25.01.2024
Physical Description:Online Resource
ISSN:1873-5894
DOI:10.1016/j.mri.2023.11.004