Exploring the time-resolving capabilities of XIDer assemblies

The XIDer R&D project, between the European Synchrotron Radiation Facility (ESRF) and Heidelberg University, is developing state-of-the-art detectors for the high-energy, high-flux beamlines of the ESRF Extremely Brilliant Source (EBS). In particular, the XIDer detector aims to tackle the signif...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Williams, Morag (VerfasserIn) , Busca, Paolo (VerfasserIn) , Collonge, Michael (VerfasserIn) , Fajardo, Pablo (VerfasserIn) , Fischer, Paulina (VerfasserIn) , Martin, Thierry (VerfasserIn) , Ritzert, Michael (VerfasserIn) , Ruat, Marie (VerfasserIn) , Schimansky, David (VerfasserIn)
Dokumenttyp: Article (Journal)
Sprache:Englisch
Veröffentlicht: December 2023
In: Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment
Year: 2023, Jahrgang: 1057, Pages: 1-4
ISSN:1872-9576
DOI:10.1016/j.nima.2023.168688
Online-Zugang:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1016/j.nima.2023.168688
Verlag, lizenzpflichtig, Volltext: https://www.sciencedirect.com/science/article/pii/S0168900223006782
Volltext
Verfasserangaben:M. Williams, P. Busca, M. Collonge, P. Fajardo, P. Fischer, T. Martin, M. Ritzert, M. Ruat, D. Schimansky
Beschreibung
Zusammenfassung:The XIDer R&D project, between the European Synchrotron Radiation Facility (ESRF) and Heidelberg University, is developing state-of-the-art detectors for the high-energy, high-flux beamlines of the ESRF Extremely Brilliant Source (EBS). In particular, the XIDer detector aims to tackle the significant challenges posed by time-resolved experiments analysing the pattern of diffracted or scattered X-rays. To fulfil the needs of these experiments, a novel on-chip incremental digital integration readout scheme with per-pixel digital data output has been implemented. The EBS beam operates with different time structures: from a near-100% duty cycle X-ray beam to an up to 5.7MHz pulsed X-ray beam. For the latter EBS mode, the XIDer ASIC has been designed to have a fast front-end and memory storage cells, such that the pulsed EBS beam can be exploited by time-resolved experiments. Recent measurements of the time-resolving capabilities of XIDer ASICs hybridised cadmium telluride and cadmium zinc telluride sensors are presented.
Beschreibung:Gesehen am 26.08.2024
Online verfügbar: 25 September 2023
Beschreibung:Online Resource
ISSN:1872-9576
DOI:10.1016/j.nima.2023.168688