Accuracy of 3D-printed models and positional trueness of removable dies fabricated by two milling centers

Objectives - To evaluate the accuracy of 3D-printed models and positional trueness of the removable dies. - Methods - A typodont incisor, canine, premolar, and molar were prepared for single crowns and digitized. Based on this scan, two sets of models (n = 10 each) were 3D-printed in two milling cen...

Full description

Saved in:
Bibliographic Details
Main Authors: Schwindling, Maria (Author) , Herpel, Christopher (Author) , Schwindling, Franz Sebastian (Author) , Kapferer-Seebacher, Ines (Author) , Vogel, Lorenz (Author) , Steiner, René (Author)
Format: Article (Journal)
Language:English
Published: October 2025
In: Journal of dentistry
Year: 2025, Volume: 161, Pages: 1-5
ISSN:1879-176X
DOI:10.1016/j.jdent.2025.105986
Online Access:Verlag, kostenfrei, Volltext: https://doi.org/10.1016/j.jdent.2025.105986
Verlag, kostenfrei, Volltext: https://www.sciencedirect.com/science/article/pii/S0300571225004300
Get full text
Author Notes:Maria Schwindling, Christopher Herpel, Franz Sebastian Schwindling, Ines Kapferer-Seebacher, Lorenz Vogel, René Steiner
Description
Summary:Objectives - To evaluate the accuracy of 3D-printed models and positional trueness of the removable dies. - Methods - A typodont incisor, canine, premolar, and molar were prepared for single crowns and digitized. Based on this scan, two sets of models (n = 10 each) were 3D-printed in two milling centers, resulting in a total of 80 dies. The two model types varied in die configuration (conical and root-formed), resin type, and post-processing techniques. Fabrication accuracy was evaluated after model delivery. The positional trueness was measured at baseline, after 10 and 50 repositioning cycles, by evaluating metric and angular die displacements. Deviations were compared between the groups using non-parametric Mann-Whitney-U tests at a significance level of 0.05. - Results - Fabrication accuracy was similar for the two model sets. Trueness/precision were 72 ± 15 µm/76 ± 19 µm for center 1. For center 2, the corresponding values were 60 ± 5 µm/79 ± 4 µm. Significant differences in positional trueness were observed between the two model types after both 10 and 50 repositioning cycles. After 10 cycles, mean die displacements were 78 ± 76 µm for center 1 and 526 ± 470 µm for center 2 (p < 0.001). These values showed minimal variation after 50 cycles, with mean die displacements of 98 ± 80 µm for center 1 and 470 ± 386 µm for center 2 (p < 0.001). Angular deviations were minimal for both groups, even after 50 cycles, with deviations below 1°. - Conclusion - While the accuracy of the 3D-printed models was adequate, the positional trueness of the dies requires improvement, as some currently available models demonstrate unacceptable discrepancies. - Clinical significance - The quality of 3D-printed models with removable dies for CAD/CAM crowns can vary substantially between milling centers. While some models can merely serve as restoration carriers, others are equipped with accurate dies that can be removed and repositioned reliably.
Item Description:Online verfügbar 22 July 2025, Version des Artikels 2 August 2025
Gesehen am 09.12.2025
Physical Description:Online Resource
ISSN:1879-176X
DOI:10.1016/j.jdent.2025.105986