Influence of tube voltage, tin filtration, and sex on radiation dose and image quality in adult chest photon-counting CT: a phantom-based signal-to-noise-based analysis = Einfluss von Röhrenspannung, Zinnfiltration und Geschlecht auf Strahlendosis und Bildqualität bei der Photon-Counting CT des Thorax bei Erwachsenen : eine phantomgestützte Analyse auf Basis des Signal-Rausch-Verhältnisses

Photon-counting computed tomography (PCCT) offers new possibilities for optimizing image quality while reducing radiation dose. However, the influence of acquisition parameters such as tube voltage and spectral shaping with tin filtration on chest imaging remains insufficiently understood. Adult mal...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Klüner, Laura Valentina (Autore) , Zensen, Sebastian Stefan (Autore) , Wiesche, Hannah aus der (Autore) , Ebenau, Melanie (Autore) , Bos, Denise (Autore) , Ocker-Serger, Raya (Autore) , Yildirim, Berk (Autore) , Meetschen, Mathias (Autore) , Salhöfer, Luca (Autore) , Guberina, Nika (Autore) , Buescher, Erik (Autore) , Welsner, Matthias (Autore) , Schaarschmidt, Benedikt (Autore) , Drews, Marcel Alexander (Autore) , Umutlu, Lale (Autore) , Forsting, Michael (Autore) , Haubold, Johannes (Autore) , Opitz, Marcel Klaus (Autore)
Natura: Article (Journal)
Lingua:inglese
Pubblicazione: 24. März 2026
In: RöFo
Year: 2026, Pages: 1-15
ISSN:1438-9010
DOI:10.1055/a-2829-0195
Accesso online:Verlag, lizenzpflichtig, Volltext: https://doi.org/10.1055/a-2829-0195
Verlag, lizenzpflichtig, Volltext: http://www.thieme-connect.de/DOI/DOI?10.1055/a-2829-0195
Testo
Note sull'autore:Laura Valentina Klüner, Sebastian Zensen, Hannah aus der Wiesche, Melanie Ebenau, Denise Bos, Raya Ocker-Serger, Berk Yildirim, Mathias Holtkamp, Luca Salhöfer, Nika Guberina, Erik Buescher, Matthias Welsner, Benedikt Schaarschmidt, Marcel Drews, Lale Umutlu, Michael Forsting, Johannes Haubold, Marcel Klaus Opitz
Descrizione
Riassunto:Photon-counting computed tomography (PCCT) offers new possibilities for optimizing image quality while reducing radiation dose. However, the influence of acquisition parameters such as tube voltage and spectral shaping with tin filtration on chest imaging remains insufficiently understood. Adult male and female anthropomorphic phantoms were scanned using a dual-source PCCT system across a broad range of image quality levels (IQL 1-100). Radiation dose and signal-to-noise ratio (SNR) were evaluated for protocols using 120 kVp and 140 kVp without tin filtration, and 100 kVp with tin filtration. The male phantom required a significantly higher tube current and radiation dose than the female, reflecting sex-based attenuation differences. Increasing the tube voltage to 140 kVp raised the radiation dose with minimal SNR improvement. Tin filtration substantially reduced the dose despite a higher mAs, with the radiation dose and tube current plateauing near IQL 80. In the low-dose range (IQL 1-20), tin filtration enabled dose reduction without saturation. Slight SNR trade-offs between bone and mediastinum highlight the need for tissue-specific considerations when optimizing PCCT chest protocols. Sex- and tissue-specific differences with tin filtration and varying tube voltages underscore baseline differences in radiation dose and image quality behavior between representative adult body geometries. These baseline relationships provide a technical foundation for future patient-specific protocol optimization.
Descrizione del documento:Artikel online veröffentlicht: 24. März 2026
Gesehen am 30.04.2026
Descrizione fisica:Online Resource
ISSN:1438-9010