Cardiac implantable electronic device lead perforation: a 25-year single-center experience

Background: Cardiac implantable electronic device (CIED) lead perforation is a rare but potentially catastrophic complication. As global device implantations increase, understanding the clinical spectrum and optimal management of this complication is essential. This study characterizes the clinical...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Maisary, Sameer al- (Autore) , Karck, Matthias (Autore) , Guzmán-Ruvalcaba, Mario Jesus (Autore) , Arif, Rawa (Autore) , Romano, Gabriele (Autore)
Natura: Article (Journal)
Lingua:inglese
Pubblicazione: 2026
In: Journal of Clinical Medicine
Year: 2026, Volume: 15, Fascicolo: 7
ISSN:2077-0383
DOI:10.3390/jcm15072705
Accesso online:Verlag, kostenfrei, Volltext: https://doi.org/10.3390/jcm15072705
Verlag, kostenfrei, Volltext: https://www.mdpi.com/2077-0383/15/7/2705
Testo
Note sull'autore:Sameer Al-Maisary, Matthias Karck, Mario Jesus Guzman-Ruvalcaba, Rawa Arif and Gabriele Romano
Descrizione
Riassunto:Background: Cardiac implantable electronic device (CIED) lead perforation is a rare but potentially catastrophic complication. As global device implantations increase, understanding the clinical spectrum and optimal management of this complication is essential. This study characterizes the clinical presentation, diagnostic strategies, and outcomes of lead perforation over a 25-year period. Methods: A retrospective analysis was conducted on 32 patients diagnosed with CIED lead perforation between 2000 and 2025 at a high-volume center. Perforations were classified by timing: acute (<24 h), subacute (1-30 days), and chronic (>30 days). Data included demographics, comorbidities, imaging modalities, and procedural interventions. Results: The mean patient age was 76.0 ± 11.7 years, with a mean body mass index (BMI) of 25.5 ± 3.4 kg/m2. Subacute presentation was the most frequent (59.3%, n = 19), followed by acute (28.1%, n = 9) and chronic (12.5%, n = 4) cases. The right ventricle was the primary site of perforation (90.6%). While chest X-rays served as an initial screening tool in 62.5% of cases, diagnosis relied on multimodal imaging, with Computed Tomography (CT) providing definitive confirmation in 31.3% of the cohort, particularly when lead parameters remained stable. Management was risk-stratified based on hemodynamic status. The majority of patients (71.9%, n = 23) underwent successful transvenous lead removal via simple traction. However, 25% (n = 8) presented with hemodynamic instability, and 21.9% (n = 7) suffered from cardiac tamponade. These high-risk cases required surgical intervention, including sternotomy (n = 4), thoracotomy (n = 2), or pericardiotomy (n = 3). Notably, 62.5% of hemodynamically unstable patients were on oral anticoagulants. All patients survived to discharge, with no in-hospital mortality. The median length of hospital stay was 3 days. Conclusions: CIED lead perforation often presents subacutely with subtle clinical signs. CT imaging has emerged as the gold standard for definitive diagnosis. While percutaneous transvenous removal is safe and effective for stable patients, immediate surgical backup is vital, as patients—particularly those on anticoagulation—can deteriorate rapidly.
Descrizione del documento:Online veröffentlicht: 2. April 2026
Gesehen am 16.06.2026
Descrizione fisica:Online Resource
ISSN:2077-0383
DOI:10.3390/jcm15072705