Subcutaneous defibrillator implantation with or without defibrillation test: the primary results of the randomized PRAETORIAN-DFT trial

BACKGROUND: - To improve survival of patients at risk of sudden cardiac death, subcutaneous implantable cardioverter defibrillators (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts d...

Description complète

Enregistré dans:
Détails bibliographiques
Auteurs principaux: Knops, Reinoud E. (Auteur) , Marquie, Christelle (Auteur) , Nordbeck, Peter (Auteur) , Tilz, Roland R. (Auteur) , Dijkshoorn, Leonard A. (Auteur) , Quast, Anne-Floor B.E. (Auteur) , Brouwer, Tom F. (Auteur) , Lambiase, Pier D. (Auteur) , Cassidy, Christopher J. (Auteur) , Boersma, Lucas V.A. (Auteur) , Burke, Martin C. (Auteur) , Betts, Timothy R. (Auteur) , Probst, Vincent (Auteur) , Manyam, Harish (Auteur) , Bracke, Frank A.L.E. (Auteur) , Bonnemeier, Hendrik (Auteur) , Kuschyk, Jürgen (Auteur) , Golovchiner, Gregory (Auteur) , de Weger, Anouk (Auteur) , Miller, Marc A. (Auteur) , de Jong, Jonas S.S.G. (Auteur) , Ghani, Abdul (Auteur) , Lewis, Nigel (Auteur) , Marijon, Eloi (Auteur) , Bijsterveld, Nick R. (Auteur) , Defaye, Pascal (Auteur) , Martin, Claire A. (Auteur) , Field, Duncan C. (Auteur) , Elders, Jan (Auteur) , Shaik, Naushad A. (Auteur) , Boveda, Serge (Auteur) , van der Stuijt, Willeke (Auteur) , de Veld, Jolien A. (Auteur) , Kooiman, Kirsten M. (Auteur) , Pepplinkhuizen, Shari (Auteur) , Kaiser, Lukas (Auteur) , Arya, Anita (Auteur) , Tukkie, Raymond (Auteur) , van Woerkens, Léon J.P.M. (Auteur) , Feenema-Aardema, Margriet W. (Auteur) , Glikson, Michael (Auteur) , Maass, Alexander H. (Auteur) , Zaidi, Amir (Auteur) , Wilde, Arthur A.M. (Auteur) , Olde Nordkamp, Louise R.A. (Auteur) , Smeding, Lonneke (Auteur) , El-Chami, Mikhael F. (Auteur)
Format: Article (Journal)
Langue:anglais
Publié: August 11, 2026
In: Circulation
Year: 2026, Volume: 154, Numéro: 6, Pages: 520-531
ISSN:1524-4539
DOI:10.1161/CIRCULATIONAHA.126.080638
Accès en ligne:Verlag, kostenfrei, Volltext: https://doi.org/10.1161/CIRCULATIONAHA.126.080638
Verlag, kostenfrei, Volltext: https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.126.080638
Accéder au texte intégral
Notes sur l'auteur:Reinoud E. Knops, MD, PhD, Christelle Marquie, MD, Peter Nordbeck, MD, Roland R. Tilz, MD, PhD, Leonard A. Dijkshoorn, MD, Anne-Floor B.E. Quast , MD, PhD; Tom F. Brouwer, MD, PhD, Pier D. Lambiase, MD, PhD, Christopher J. Cassidy, MD, Lucas V.A. Boersma, MD, PhD, Martin C. Burke, DO, Timothy R. Betts, MD, Vincent Probst, MD, PhD, Harish Manyam, MD, Frank A.L.E. Bracke, MD, PhD, Hendrik Bonnemeier, MD, PhD, Jürgen Kuschyk, MD, Gregory Golovchiner, MD, Anouk de Weger, MSc, Marc A. Miller, MD, Jonas S.S.G. de Jong, MD, PhD, Abdul Ghani, MD, PhD, Nigel Lewis, MD, PhD, Eloi Marijon, MD, PhD, Nick R. Bijsterveld, MD, PhD, Pascal Defaye, MD, Claire A. Martin, MD, PhD, Duncan C.Field, MD, Jan Elders, MPA, Naushad A. Shaik, MD, Serge Boveda, MD, PhD, Willeke van der Stuijt, MD, PhD, Jolien A. de Veld, MD, Kirsten M. Kooiman, MPA, Shari Pepplinkhuizen, MD, Lukas Kaiser, MD, Anita Arya, MD, Raymond Tukkie, MD, PhD, Léon J.P.M. van Woerkens, MD, PhD, Margriet W. Feenema-Aardema, MD, Michael Glikson, MD, Alexander H. Maass, MD, PhD, Amir Zaidi, MD, Arthur A.M. Wilde, MD, PhD, Louise R.A. Olde Nordkamp, MD, PhD, Lonneke Smeding, PhD, Mikhael F. El-Chami, MD; on behalf of the PRAETORIAN-DFT Investigators
Description
Résumé:BACKGROUND: - To improve survival of patients at risk of sudden cardiac death, subcutaneous implantable cardioverter defibrillators (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes on the basis of chest X-ray. The PRAETORIAN-DFT (Prospective Randomized Comparative Trial of Subcutaneous Implantable Cardioverter Defibrillator Implantation With and Without Defibrillation Testing) trial evaluated whether omission of DF testing guided by the PRAETORIAN score is noninferior for first-shock efficacy. - METHODS: - In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary end point was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for noninferiority with a 3% absolute risk margin. Secondary end points included mortality, potential DF testing-related complications, and S-ICD revisions. - RESULTS: - The included 965 patients (No-DF testing, n=483; DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (-0.6% [95% CI, -2.6 to 1.4], P<0.001). There were no significant differences in all-cause mortality (hazard ratio [HR], 0.9 [95% CI, 0.6-1.4]) or arrhythmic death (HR, 0.4 [95% CI, 0.04-3.4]). Potential DF testing-related complications occurred in 1.7% in the DF testing group. Postoperative S-ICD revisions due to inadequate positioning were identical between groups (n=2 each). - CONCLUSIONS: - PRAETORIAN score-guided omission of DF testing after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. - REGISTRATION: - URL: https://www.clinicaltrials.gov; Unique identifier: NCT03495297.
Description:Gesehen am 07.09.2026
Description matérielle:Online Resource
ISSN:1524-4539
DOI:10.1161/CIRCULATIONAHA.126.080638