Real-life application of a point-of-care biosensor for phenylalanine in patients with phenylketonuria
Phenylketonuria (PKU) is a rare metabolic disorder causing elevated phenylalanine (PHE) levels requiring lifelong dietary or pharmacological management and regular monitoring. Current PHE monitoring methods, such as tandem mass spectrometry (FIA-MS/MS), are laboratory and sample transport-dependent,...
Salvato in:
| Autori principali: | , , , , , , , , , , , , , , |
|---|---|
| Natura: | Article (Journal) |
| Lingua: | inglese |
| Pubblicazione: |
May 2026
|
| In: |
Journal of inherited metabolic disease
Year: 2026, Volume: 49, Fascicolo: 3, Pages: 1-11 |
| ISSN: | 1573-2665 |
| DOI: | 10.1002/jimd.70187 |
| Accesso online: | Verlag, kostenfrei, Volltext: https://doi.org/10.1002/jimd.70187 Verlag, kostenfrei, Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jimd.70187 |
| Note sull'autore: | Corentin Gondrand, Anna T. Reischl-Hajiabadi, Estelle Bonedeau, Nicolas Weiß, Gerd Schneider, Maurice Fahn, Frederic Myers, Philipp Minel Städle, Kathrin Jeltsch, Georg F. Hoffmann, Jürgen G. Okun, Dorothea Haas, Sven F. Garbade, Kai Johnsson, Thomas Opladen |
| Riassunto: | Phenylketonuria (PKU) is a rare metabolic disorder causing elevated phenylalanine (PHE) levels requiring lifelong dietary or pharmacological management and regular monitoring. Current PHE monitoring methods, such as tandem mass spectrometry (FIA-MS/MS), are laboratory and sample transport-dependent, leading to delays in obtaining results. This highlights the need for accessible point-of-care (PoC) solutions. Building on a previously developed bioluminescence-based PHE quantification method, we created a PoC PHE sensor integrated with a smartphone app (phenyx app) for real-time monitoring and data sharing. In a clinical study with PKU patients, we evaluated the reliability of the sensor and the app by comparing at-home PHE measurements with dried blood samples (DBS) analyzed using the gold standard FIA-MS/MS. We also assessed time differences between sampling and results, sensor practicality, and user experience. Forty-seven PKU patients (median age 10.0 years, range 0.7-53.4) performed one supervised and four at-home measurements using the PHE sensor, alongside DBS sampling for FIA-MS/MS. The sensor showed higher PHE values than FIA-MS/MS, with a mean difference of 84.8 μmol/L (p = 0.0017). Variability was influenced by test supervision (clinic vs. home) and test kit age (greater difference in older batches, p = 0.001). Usability of the PHE sensor and phenyx app was rated favorably; all patients preferred the PHE sensor over laboratory testing. PoC measurement using the PHE sensor and phenyx app is feasible, reliable, and provides rapid results comparable to FIA-MS/MS, representing a key step toward patient self-testing. Trial Registration: NCT05998109, NCT06940193, DRKS00031972. |
|---|---|
| Descrizione del documento: | Online veröffentlicht: 16. April 2026 Gesehen am 22.06.2026 |
| Descrizione fisica: | Online Resource |
| ISSN: | 1573-2665 |
| DOI: | 10.1002/jimd.70187 |